?|a€“a°?¥a?ao?§a?a€???a?aμ 6

DC 12V Multifunction Self-lock Relay PLC Cycle Timer Module Delay Time Switch

 

Description:

  • 100% brand new and high quality
  • Material: Electrical components
  • Color: See pictures
  • Description:
  • FRM01 multifunction relay control module, specifically designed for a variety of users with different requirements,
    the use of micro-controller as the primary
    controllers, presets 18 types of functions, and can be based on user requirements, customize and add other specific functions.
    genuine high quality power relay modules, high-power high-voltage transistors, red, blue beacons, military rank on two sides
    PCB board, cloth board to consider a global approach, stable performance, can be widely used in a variety of type of power control applications.
     
  • Features:
  • 1 new update to version 2.0, the module features eight types before, it increased to 18 types, to meet the needs of multiple applications;
  • 2 increase supply anti-reverse function, power not to damage the wrong form;
  • 3 uses top-quality high-voltage power modules, discrete power supply before replacing the most stable and reliable system;
  • 4 rose 0.1 seconds timing, timing accuracy from the previous 0.1 seconds, upgrade to 0.01 seconds;
    increase of 5 in the automatic power saving feature, users can set independently.
  • 6. Size: 66x40x1.5mm (about)
     
  • Module functions:
  • Tips: 1-8 function on power-up of 9-18 Start auto-function require high pulse signal (high duration is shorter than 20 ms, hereinafter the same) trigger the start.
     
  • Feature 1:
  • Withdrawal Timing: After the ignition, the relay delay time pulling T1, T1 between 0.1 seconds-270 hours adjustable, CH1 interface to a high-level pulse signal, repeat the above functions;
     
  • Function 2:
  • Timing off: when the power relay, relay delay time unplugged T1, T1 between 0.1 seconds-270 hours adjustable, CH1 interface to a high-level pulse signal, repeat the above functions;
     
  • Function 3:
    Timing pull out again: After power relay not to pull, the delay time T1 reaches the relay is energized; pull the relay off after time t2 of arrival, delay time T1 and T2 in 0.1 seconds-270 hours between adjustable, CH1 interface to a
    high pulse signal, repeat the above functions;
     
  • Function 4:
    Timing and then pull off: After the ignition, immediately pull the relay, the relay off delay time T1 after arrival; T2 time relay comes after disconnecting, -270 hours in 0.1 seconds, the lag time between T1 and T2 adjustable for CH1 interface a high pulse signal, repeat the above functions;
     
  • Function 5:
    Endless loop timing modes 1: After power relay not to pull, after the delay time T1 reaches the relay is energized; pull off the relay after the time T2 comes, and then repeat the above condition, the delay time T1 and T2 in adjustable between 0.1 second-270 hours, giving a high-level pulse signal CH1 interface, you can restart functions above;
     
  • Function 6:
    Endless loop timing mode 2: After the ignition, immediately pull the relay delay time T1 reaches the relay off; comes after disconnecting relay T2 time, and then repeat the above condition, the delay time T1 and T2 in 0.1 seconds adjustable between-270 hours, giving a high-level interface CH1 pulse signal, you can restart the functions of which above;
     
  • Function 7:
    Finite loop timing mode 1: 5 on the basis of functionality, increasing the number of cycles of operation, this time between T1 and T2 in 0.1 seconds adjustable adjustable-9999 NX cycles seconds between 1-9999 times for CH1 interface of a high pulse signal , the above functions can be re-started;
     
  • Function 8:
    Finite loop timing mode 2: 6, on the basis of the function, by increasing the number of cycles of operation, this time between T1 and T2 in 0.1 seconds adjustable adjustable-9999 NX cycles seconds between 1-9999 times for CH1 interface a pulse signal above, the above functions can be re-started;
     
  • Function 9:
    latching relay mode: CH1 interface to transmit a high-level pulse signal, relay, giving a high pulse signal relay disconnected.
     
  • Function 10:
    relay activation mode: CH1 interface to a signal relay, relay, high disappear, disconnect relay.
     
  • Function 11:
    pull the trigger timing: After power relay does not act, a high level of CH1 pulse signal interface, the relay delay time pulling T1, T1 between 0.1 seconds-270 hours adjustable, repeat for CH1 high-level pulse signal interface, repeat the above function;

    Function 12:
    Timing off: After power relay does not act, a relay of CH1 for high level pulse signal interface, the relay off delay time T1, T1 between 0.1 seconds-270 hours adjustable, repeat for CH1 interface of a high pulse signal, repeat the above functions;
     
  • Function 13:
    pull the trigger and disconnect timing: After power relay does not act, CH1 interface to a high-level pulse signal, the delay time T1 reaches the relay is energized; Pull the relay off after T2 time of arrival, time delay T1 and T2 of 0.1 seconds-270 hours adjustable, repeat CH1 interface to a high-level pulse signal, repeat the above functions;
     
  • Function 14:
    disconnect and then pull the trigger timing: After power relay does not act, a high level pulse CH1, immediately pull the relay signal interface, the relay off delay time T1 after arrival; T2 time relay comes after disconnection, time delay between T1 and T2 in 0.1 seconds-270 hours adjustable, repeat CH1 interface to a high-level pulse signal, repeat the above functions;
     
  • Function 15:
    Infinite Loop Timing Mode 1: after power relay does not operate CH1 interface to a high-level pulse signal, the delay time T1 reaches the relay is energized; pull off the relay of the T2 arrival time, and then repeat the above condition, the extension when the time between T1 and T2 in 0.1 seconds-270 hours adjustable, repeat CH1 interface to a high-level pulse signal, the above functions can be re-started;
     
  • Function 16:
    Endless loop timing mode 2: After power relay does not act, a pulse for CH1 high level, immediately pull the relay signal interface, the relay off delay time T1 after the arrival; break time T2 after reaching the relay, then repeat the above condition, the delay time between T1 and T2 in 0.1 seconds-270 hours adjustable, repeat CH1 interface to a high-level pulse signal, the above functions can be re-started;
     
  • Function 17:
    Finite mode timing loop 1: 15 on the basis of functionality, increasing the number of cycles of operation, this time between T1 and T2 in 0.1 seconds adjustable adjustable-9999 NX cycles seconds between 1-9999 times, repeating for CH1 interface of a signal high pulse, the above functions can be re-started;
     
  • Function 18:
    Finite mode timing loop 2: 16 on the basis of functionality, increasing the number of cycles of operation, this time between T1 and T2 in 0.1 seconds adjustable adjustable-9999 NX cycles seconds between 1-9999 times, repeating for CH1 interface of a signal high pulse, the above functions can be re-started;
     
  • Connections:
  • Side control module: there are wire interface, all interfaces are terminal
  • 1, DC + 12 V positive
  • 2, DC-: negative power
  • 3, CH1: Interface Input Detection
  • Relay outputs: a wireless interface, all interfaces are terminal
  • 1, NO: normally open (. Before the relay closes, this pin is not connected. After the relay closes, the short stud connects with COM)
  • 2, COM: Relay Common Interface
  • 3, NC: normally closed (. Before the relay closes, this pin to connect with COM. After the relay closes, the pin is not connected)
  • No retail Package
  • Quantity:1Pc
  • Note: Due to the difference between different monitors, the picture may not reflect  the actual color of the item. Thank you!!

Package includes:

  • 1Pc x  DC 12V Multifunctional Auto-lock Relay PLC Cycle Timer Time Delay Switch Module