NO.6000III Multifunction Timegrapher Watch Timing Machine Watch Tester Tool 


Note: the watch (on picture) is not included

Specification:

1. Test Range: The mechanical watch day rate deviation,amplitude, beat error and record the beat number curve.

2. Beat Number: Automatic test common beat number, also manual select test the special beat number.

3. Day Rate Deviation Measurement: Range ±999 s/day; Resolution: 1 s /day

4: Amplitude Measurement: Range: 100 - 360°; Resolution: 1° (The lift angle can affect theamplitude, and the range is 30 - 70°; the amplitude doesn't  exceed 330° innormal circumstances)

5. The Period Time of Measurement Average Value: 2 s, 4 s, 8 s, 12 s, 20 s, 30 s, 60 s

6. Beat Error (the frequency error) Measurement: Range: 0.0 - 9.9 ms, Resolution: 0.1 ms

7. Lift Angle: Range: 30 - 70°,and the default value is 52°.

8. Supply Voltage: The single 100 - 240 V~, 0.1 A, 50 – 60 Hz.

9. The Measurement Orientation: 6 kinds of orientations.

10. The Diagram Color: Display in blue, white, yellow, green and black color.

11. Working Environment: 0 - 50¡æ, the relative humidity is 0 - 80%RH.

12. Outer Case: The light grey in plastic cement.

Features:

1. Color LCD screen;
 
2. Can automatic adjust the signal intensity according to the different watch.
 
3.  Can automatic calculate and display the day rate, amplitude and beat error.
 
4. Can automatic tests the common beat watches, otherwise you can manually select for the special ones.
 
5. Can select the test period of 2 s, 4 s, 8 s, 12 s, 20 s, 30 s, 60 s, which can calculate the average value of corresponding period.
 
6. 6 kinds of test orientation can be set;the simulation sound can be set.
 
7. Builds in a real time clock, easy to tune up the watch.
 
8.   The printer is optional; the parameters of the watch can be printed.

The automatic select beat number by the instrument as below:

12000, 14400, 18000, 19800, 21600, 25200, 28800, 36000, 43200

The instrument automatic display the closet beat number if the watch beat number is not in the automatic selection range, but the testresult is incorrect, so need to select the beat number manually. The manual selection can select the special beat number.

The manual select beat number as below:

3600, 6000, 7200, 7380, 7440, 7800, 9000, 9100, 10800, 11880, 12000, 12342, 12480, 12600, 13320, 13440, 13500, 14000, 14040, 14160, 14200, 14280, 14400, 14520, 14580, 14760, 14850, 15000, 15360, 15600, 16200, 16320, 16800, 17196, 17258, 17280, 17786, 17897, 18000, 18049, 18514, 19332, 19440, 19800, 20160, 20222, 20944, 21000, 21031, 21306, 21600, 25200, 28800, 32400, 36000, 43200