ECG300G ECG Machine

         

Brief Introduction

ECG300G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting any rhythm lead, case database management.

Function

1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.

2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.

3)Multiply printing modes and formats, including manual, auto 4×3, auto 3×4+1, auto 3×4, auto 2×6+1, auto 2×6, auto 3-2+1, auto 3-2, auto 1×12+1, auto 1×12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.

4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.

5)Built-in memory stores up to 1000 cases, convenient for case review and statistic.

6)Multi-language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Kazakstan, Russian, Ukrainian, Serbian and Slovenian) interface and report.

Performance

Input mode: floating and defibrillation protection

Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)

CMRR: >60dB, >100dB(add filter)

Time constant:≥ 3.2s

Patient leak current: <10µA

Calibration voltage: 1mV

Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%

Noise level: <15µVp-p

Input circuit current: ≤50nA

Input impedance: ≥50MΩ

Sampling accuracy: 12-bit

Safety classification: class I, type CF and defibrillation-proof applied part

Recording mode: thermal printing system

Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.

Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.

Manual record: set record according to record format, manually switching leads.

Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)

Paper size: 80mm(W)×20m(L)

Sampling frequency: 1000Hz

EMG interference filter: 25Hz/35Hz (-3dB)

Power frequency filter: AC 50Hz/60Hz(-20dB)

Paper speed: 

Auto: 25, 50mm/s, ±5%

Rhythm: 25, 50mm/s, ±5%

Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5%

Power supply: 

AC: 100V~240V(50/60Hz)

DC: 7.4V/3500mAh rechargeable lithium battery

Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V

Waterproof degree: IPX0

Working mode: continuous working


Accessories

Standard:

A lead cable

A limb electrode

A chest electrode

A thermal recording paper

A power cord

An earth wire

A user manual

ECG-Sync software+USB cable 


Optional:

ECG electrode

Bag 

Conductive gel

Physical characteristic

Working environment

Temperature: 5℃~40℃

Relative humidity: 25%~95%(non-condensing)

Atmospheric pressure: 700hPa~1060hPa

Transport and storage environment

Temperature: -40℃~+55℃

Relative humidity: ≤95%

Atmospheric pressure: 500hPa~1060hPa

Dimension: 315mm(L) × 215mm(W) × 77mm(H)

Weigh: 1.6Kg

Optional configuration 

Refer to BOM.

Shipping

By Airmail:  Generally, about 2-3 weeks

By Express: Generally, about 5-10 working days to UK, USA, AU and so on.               
We can also ship the item through express service like DHL, UPS, if you are ready to pay the  extra charge.

Terms of Sale

Buy Safe Product!
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:

The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTGwith the code 197923and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K Approved

Taxes, Customs & Duties            
There are not extra taxes, VAT or other unmentioned payment. You pay us with goods subtotal + shipping cost (not include duties). But you need to pay for the import duties in case that occurred for certain goods.

Return - After service
We offer 60 days return policy. 100% satisfaction is our goal!
1.All items are brand new ,with 1 years warranty.              
2.We will refund the money to you when we get the return items or replace item for you.

About Us

Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.At present there are more than 1200 employees in our company.

We are looking forward to establishing a successful business relationship with you.