2in1 Hantek Digital Oscilloscope + Multimeter 40MHz 70MHz 250MSa/s 2C42 2C72
Description:
Function of video help:scan code on back of machine to get help of video course;
Interface Review
Powerful PC software
Oscilloscope powerful functions: 20 kinds of automatic measurement, cursor measurement,
waveform printing and saving functions, REF and Math functions, Pass / Fail functions.
The waveform generator is able to draw and output arbitrary waveforms on its PC software
Its multimeter with recorder function, which support the measurement resultsto nerate the curves
and analyze them.
Parameter:
Model | Hantek2D72 | Hantek2D42 | Hantek2C72 | Hantek2C42 |
Oscilloscope Mode | ||||
Bandwidth | 70MHz | 40MHz | 70MHz | 40MHz |
Channel | 2CH+DMM+AWG | 2CH+DMM+AWG | 2CH+DMM | 2CH+DMM |
Horizontal | ||||
Sample Rate Range | 250MSa/s(Single-channel), 125MSa/s(Dual-channel) | |||
Waveform Interpolation | (sin x)/x | |||
Record Length | Max. 6K for single-channel; 3K samples per dual-channel | |||
SEC/DIV Range | 5ns/div~500s/div 1, 2, 5 sequence | |||
Vertical | ||||
A/D Converter | 8-bit resolution,each channel sampled simultaneously | |||
VOLTS/DIV Range | 10mV/div~10V/divat input BNC | |||
Bandwidth Limit, typical | 20MHz | |||
Low Frequency Response (-3db) | ≤10Hz at BNC | |||
Rise Time at BNC, typical | ≤5ns | |||
DC Gain Accuracy | ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div | |||
Note: Bandwidth reduced to 6MHz when using a 1X probe. | ||||
Acquisition | ||||
Acquisition Modes | Normal | |||
Trigger | ||||
Type | Edge | |||
Mode | Auto, Normal, single | |||
Level | ±4 divisions from center of screen | |||
Trigger Level Accuracy | 0.2div × volts/div within ±4 divisions from center of screen | |||
Slope | Rising, Falling, Rising & Falling | |||
Source | CH1/CH2 | |||
Input | ||||
Coupling | DC, AC or GND | |||
Input Impedance, | 25pF±3 pF, 1MΩ±2% | |||
DC coupled | ||||
Probe Attenuation | 1X, 10X | |||
Supported Probe Attenuation Factors | 1X, 10X, 100X, 1000X | |||
Maximum Input Voltage | 150VRMS | |||
Measurement | ||||
Cursor | Voltage difference between cursors: △V | |||
Time difference between cursors: △T | ||||
Automatic Measurements | Frequency, Amplitude | |||
Arbitrary Waveform Generator Mode | ||||
Waveform Frequency | Sine: 1Hz~25MHz | - | - | |
Square: 1Hz~10MHz | - | - | ||
Ramp: 1Hz~1MHz | - | - | ||
EXP: 1Hz~5MHz | - | - | ||
Sampling | 250MSa/s | - | - | |
Amplitude | 2.5Vpp(50Ω) | - | - | |
5Vpp(High impedance) | - | - | ||
Frequency Resolution | 0.10% | - | - | |
Channel | 1CH waveform output | - | - | |
Waveform Depth | 512Sa | - | - | |
Vertical Resolution | 12 bit | - | - | |
Output Impedance | 50 Ω | - | - | |
DMM-Digital Multimeter | ||||
Maximum Resolution | 4000 Counts | |||
DMM Testing Modes | Voltage,Current,Resistance,Capacitance,Diode &On-Off | |||
Maximum Input Voltage | AC:600V, DC: 800V | |||
Maximum Input Current | AC: 10A, DC:10A | |||
Input Impedance | 10MΩ | |||
Measurement Term | Range | Accuracy | Resolution | |
DC Voltage | 400.00mV | ± (0.8% + 5) | 100uV | |
4.000V | 1mV | |||
40.00V | 10mV | |||
400.0V | 100mV | |||
600.0V | ± (1% + 2) | 1V | ||
Overload protection: 400mV: 250V, other: 600Vrms. | ||||
AC Voltage | 4.000V | ± (1.2% + 5) | 1mV | |
40.00V | 10mV | |||
400.0V | 100mV | |||
600.0V | ±(1.5% + 5) | 1V | ||
Frequency: 40Hz~400Hz; | ||||
Frequency of 400V and 600V: 40Hz~100Hz | ||||
DC Current | 40.00mA | ± (1% + 2) | 10uA | |
200.0mA | ± (1.5% + 2) | 100uA | ||
4.000A | ± (1.8% + 2) | 1mA | ||
10.00A | ± (3% + 2) | 10mA | ||
Overload protection: | ||||
self restoring fuse: 200mA/250V, 4A and 10A range no fuse. | ||||
AC Current | 40.00mA | ± (1.3% + 2) | 10uA | |
400.0mA | ± (1.8% + 2) | 100uA | ||
4.000A | ± (2% + 3) | 1mA | ||
10.00A | ± (3% + 5) | 10mA | ||
Frequency: 40Hz~400Hz; | ||||
self restoring fuse: 200mA/250V, 4A and 10A range no fuse. | ||||
Resistance | 400.0Ω | ±(1% + 3) | 0.1Ω | |
4.000KΩ | ±(1.2% + 5) | 1Ω | ||
60.00KΩ | 10Ω | |||
400.0KΩ | 100Ω | |||
4.000MΩ | 1KΩ | |||
40.00MΩ | ± (1.5%±3) | 10KΩ | ||
Overload protection: 220Vrms | ||||
Capacitance | 40.00nF | ±(3% + 5) | 10pF | |
400.0nF | 100pF | |||
4.000uF | 1nF | |||
40.00uF | 10nF | |||
100.0uF | 100nF | |||
Overload protection: 220Vrms | ||||
Diode | 0V~2.0V | |||
On-Off | <50Ω | |||
General Specifications | ||||
Display | ||||
Display Type | 2.8 inch64K color TFT | |||
Display Resolution | 320 horizontal by 240 vertical pixels | |||
Display Contrast | Adjustable | |||
Power Supply | ||||
Supply Voltage | 100V-240VAC, 50Hz-60Hz; DC INPUT: 5VDC, 2A | |||
Power Consumption | <2.5W | |||
Fuse | T, 3A | |||
Battery | 2600mA*2 | |||
Environmental | ||||
Operating Temperature | 0~50 °C (32~122 °F) | |||
Storage Temperature | -40~+71 °C (-40~159.8 °F) | |||
Humidity | ≤+104℉(≤+40°C): ≤90% relative humidity | |||
106℉~122℉ (+41°C ~50°C): ≤60% relative humidity | ||||
Cooling Method | Convection | |||
Altitude | Operating and | 3,000m (10,000 feet) | ||
Nonoperating | ||||
Mechanical Shock | Random Vibration | 0.31gRMS from 50Hz to 500Hz, 10 minutes on each axis | ||
Nonoperating | 2.46gRMS from 5Hz to 500Hz, 10 minutes on each axis | |||
Operating | 50g, 11ms, half sine | |||
Mechanical | ||||
Dimension | 199 x 98x 40mm (L x W x H) | |||
Weight | 624g | |||
Standard Accessories |
Probe*1, Clip Probe*2, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 100MHz Oscilloscope Probe*1(plus)
|
Probe*1, Clip Probe*2, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 100MHz Oscilloscope Probe*1(plus) |
Probe*1, Clip Probe*1, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 100MHz Oscilloscope Probe*1(plus) |
Probe*1, Clip Probe*1, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 100MHz Oscilloscope Probe*1(plus) |
Payment
1.We only accept PayPal payment.
2.For combined shipping, do welcome to contact with us.
Shipping
1.We ship to worldwide.
2.We only ship to PayPal confirmed address. Please ensure that your PayPal address is correct.
3.Orders will be shipped within 1-3 business days after payment has been cleared
4.We are not responsible for duties and customs fee. You can tell us the shipping value you want. We will meet your demand.
Return
1.Any problem with your purchase, shipment return/exchange, please contact us before opening a case.
2.Please contact us within 14 days after receiving the items.
3.Return shipping should paid by buyers.
4.Refund will be given money back or replacement (buyer's choice).
Feedback
1.If you're satisfied with our products, please leave a positive feedback and perfect five stars. thank you in advance.
2.If you fee that we do not meet your demand ,or any problems with your purchase, shipping return/ exchange,
please contact with us before opening a case or leaving us bad feedback ,thanks a lot.