DMM is a 6 1/2 digital multimeter with high accuracy, stability and speed. The digital multimeter provides a
maximum measurement speed of 1000 readings/sec. DMM has a 0.0035% DC voltage basic accuracy,
0.01% basic resistance accuracy and other high performance. DMM has broad measurement ranges:

DC voltage from 0.1μV to 1000V 
AC (RMS) voltage from 0.1μV to 750V, or about 1000V Peak
DC current from 10nA to 12A
AC (RMS) current from 10nA to 12A 
Two and four-wire resistance from 0.1mΩ to 120M. 
Frequency from 5Hz to 1MHz
 
Some additional capabilities of Model DMM:

Full range of functions: In addition to those listed above, The DMM functions include period, dB,
dBm, continuity, diode testing, mX+b and percent.
Programming languages and remote control interfaces: The DMM provides the SCPI
programming language and three remote control interface ports: USB Device, IEEE-488/GPIB
(optional) and RS-232C (optional).
Reading and setup storage: Up to 512 readings and 10 sets of settings can be stored and
retrieved.
Closed-cover calibration: The digital multimeter can be calibrated either from the front panel or
through the remote control interface.

Operating Environment:
 
Power supply: 110V/220V ±10%
Line frequency: 50Hz / 60Hz ±5%
Power consumption: <20VA
Operating temperature: 0℃ to 40℃
Humidity: ≤ 90%RH

Dimensions and Weight:
 
Dimensions(W×H×D):225mm×100mm×355mm
Net weight: Around 5Kg

Accessories:

Test leads x2 (Model TH26036)
Power cord 
Two 500mA fuses
Two 1A fuses
PDF Operation Manual
Quality and warranty certificate
Test report
Note: IEEE-488 and RS232C interface is optional

 

Technical Specifications:

Specifications Assumptions

One year calibration cycle.

Operating temperature at 18 ℃ to 28 ℃

Accuracy is expressed as: ±(% of reading + % of range) after 30 minutes’ warm-up.

Temperature Coefficient: add ± [0.1% × (the applicable accuracy)/ ℃] for 0℃ to 18 ℃ and 28 ℃ to 40℃;

Relative Humidity: Up to 80% for 0 ℃ to 28 ℃ (75% RH for 10MΩ and  above ranges of resistance measurement). Up to 70 for 28℃ to 40 ℃.

 

Displayed Readings and Reading rates

Full Scale displayed reading

                                Slow                  Med                    Fast

 

                             119,999,9               119,999                11,999

     Reading rates on front panel (Reading/sec, Approximate)

 

         Measurement Function                     Slow           Med            Fast

              DCV                                                 2            16             57

             DCA                                                 2            16             57

             ACV                                                1.5             4             25

             ACA                                                1.5             4             25

             2-Wire Ω (Ranges below 100kΩ )     2            16             57

             2-Wire Ω (100kΩ range and above)  2            16             25

             4-Wire Ω (Ranges below 100kΩ)     1.5           10             33

             4-Wire Ω (100kΩ range and above)   1.5            10             20

              Freq                                                   1            10             100

              Period                                                1            10             100

              Diode                                          ————              16        ————

             Continuity                                      ————           ————        57

                                                 

DC CHARACTERISTICS

CONDITIONS: SLOW or MED with filter of 10

ACCURACY: ±(% of reading + % of range)

 

● DC Voltage                                                                                                                    

 Rate     Range      Resolution   Input Impedance      Accuracy      Temp.Coefficient 0℃-18℃;28℃-50℃                                                                               

         100.0000mV      0.1 μV        >10G          0.0065+0.0045 (1)     0.0005+0.0005

         1.000000 V       1 μV         >10G          0.0040+0.0009 (1)     0.0005+0.0001

 Slow    10.00000 V       10μV         >10G          0.0035+0.0005         0.0005+0.0001

         100.0000 V       100μV        10M±1%        0.0045+0.0006         0.0005+0.0001

         1000.000 V (2)   1 mV         10M±1%        0.0055+0.0015         0.0005+0.0001

         100.000mV        1 μV         >10G          0.0065+0.0090 (1)     0.0005+0.0005

         1.00000 V        10 μV        >10G          0.0040+0.0018 (1)     0.0005+0.0001

         10.0000 V        100μV        >10G          0.0035+0.0010         0.0005+0.0001

  Med

         100.000 V        1 mV         10M±1%        0.0045+0.0012         0.0005+0.0001

         1000.00 V (2)    10 mV        10M±1%        0.0055+0.0030         0.0005+0.0001

         100.00mV         10 μV        >10G          0.0200+0.040 (1)      0.0005+0.0005

         1.0000 V         100μV        >10G          0.0200+0.020 (1)      0.0005+0.0001

  Fast   10.000 V         1 mV         >10G          0.0200+0.020          0.0005+0.0001

         100.00 V         10 mV        10M±1%        0.0200+0.020          0.0005+0.0001

         1000.0 V (2)     100mV        10M±1%        0.0200+0.020          0.0005+0.0001

(1) under REL status

(2) 1% over-range (1010V) is readable at 1000V range.

Maximum input voltage: 1000VDC or peak ac for all ranges. 

                                               

●  Resistance (2-Wire and 4-wire)                                                                                   

 Rate   Range(1)  Resolution    Test Current               Accuracy        Temp.Coe.0℃-18℃;28℃-50℃                                                                                    

         100.0000Ω  100µΩ                   1 mA             0.010+0.004 (2)       0.0006+0.0005

         1.000000kΩ 1mΩ                     1 mA             0.010+0.001 (2)       0.0006+0.0001

         10.00000kΩ 10mΩ                    100μA              0.010+0.001         0.0006+0.0001

 Slow    100.0000 kΩ 100mΩ                  10μA               0.010+0.001         0.0006+0.0001

         1.000000MΩ 1 Ω                     10μA               0.010+0.001         0.0010+0.0002

         10.00000MΩ 10Ω                  7.0*Rx/(10M+Rx)       0.040+0.001         0.0030+0.0004

         100.0000MΩ 100Ω                 7.0*Rx/(10M+Rx)       0.800+0.010         0.1500+0.0002

         100.000Ω        1mΩ                1 mA             0.020+0.008 (2)       0.0006+0.0005

         1.00000 kΩ  10mΩ                   1 mA             0.020+0.002 (2)       0.0006+0.0001

         10.0000 kΩ  100mΩ                  100μA              0.020+0.002         0.0006+0.0001

  Med    100.000 kΩ  1 Ω                    10μA               0.020+0.002         0.0006+0.0001

         1.00000MΩ  10 Ω                    10μA               0.020+0.002         0.0010+0.0002

         10.0000MΩ  100Ω                 7.0*Rx/(10M+Rx)       0.080+0.002         0.0030+0.0004

         100.000MΩ  1 kΩ                 7.0*Rx/(10M+Rx)       1.200+0.020         0.1500+0.0002

         100.00Ω         10mΩ               1 mA             0.020+0.010 (2)       0.0006+0.0005

         1.0000 kΩ       100mΩ              1 mA             0.020+0.010 (2)       0.0006+0.0001

         10.000 kΩ       1 Ω                100μA              0.020+0.010         0.0006+0.0001

  Fast   100.00 kΩ       10 Ω               10μA               0.020+0.010         0.0006+0.0001

         1.0000 MΩ  100Ω                    10μA               0.020+0.010         0.0010+0.0002

         10.000 MΩ  1 kΩ                 7.0*Rx/(10M+Rx)       0.080+0.010         0.0030+0.0004

         100.00 MΩ  10 kΩ                7.0*Rx/(10M+Rx)       1.200+0.050         0.1500+0.0002

(1) In order to eliminate the noise interference, which might be induced to the test leads, it is recommended to use a shielded test cable for measuring resistance above 100kΩ.

(2) Using REL function

Maximum Input Protection: 1000VDC or 750VAC for all ranges.

Open circuit voltage: Maximum voltage is 13.3V dc for 100Ω,1kΩ,10Ω,10MΩ and 100MΩ ranges;

                      Maximum voltage is 7V dc for 100kΩ and 1M ranges.

                                                 
●  DC Current 
                                                                                                                                        

 Rate       Range     Resolution    Burden Volt.(1) & Shunt Resistor  Accuracy  Temp.Coe.0℃-18℃;28℃-50℃                                                 

 Slow      10.00000mA      10 nA           <0.15V/ 10.1 Ω         0.05+0.004 (2)      0.002+0.0020

          100.0000mA       100nA           <1.5V / 10.1 Ω         0.05+0.004 (2)      0.002+0.0005

          1.000000 A       1 μA            <0.3V / 0.1 Ω           0.08+0.004         0.005+0.0010

          10.00000 A       10 μA           <0.15V / 0.01 Ω         0.25+0.015         0.005+0.0020

 Med       10.0000mA       0.1 μA          <0.15V/ 10.1 Ω         0.05+0.008 (2)      0.002+0.0020

          100.000mA        1 μA            <1.5V / 10.1 Ω         0.05+0.008 (2)      0.002+0.0005

          1.00000 A        10 μA           <0.3V / 0.1 Ω           0.08+0.008         0.005+0.0010

          10.0000 A        100 μA          <0.15V / 0.01 Ω         0.25+0.008         0.005+0.0020

 Fast      10.000mA        1 μA            <0.15V/ 10.1 Ω         0.10+0.015 (2)      0.002+0.0020

          100.00mA         10 μA           <1.5V / 10.1 Ω         0.10+0.015 (2)      0.002+0.0005

          1.0000 A         100 μA          <0.3V / 0.1 Ω           0.15+0.015         0.005+0.0010

          10.000 A         1mA             <0.15V / 0.01 Ω         0.25+0.015         0.005+0.0020

 (1) Typical voltage across the input terminals at full scale reading.

 (2) Use REL function

Maximum Input and Overload Current Protection: 2A/ 250V fuse.

                                             
Continuity 
                                                                            

        Rate       Range       Resolution   Test Current      Accuracy     Temp.Coe.0℃-18℃;28℃-50℃    

        Fast        1 kΩ        100mΩ            1mA          0.010+0.020      0.001+0.002

Maximum Input Protection: 1000VDC or 750VAC for all ranges.

Open circuit voltage: <13.3V DC

Test Current: around 1mA DC

Threshold resistance: From 1Ω to 1000Ω, default of power on is 10Ω

 

Diode                                 
           Rate       Range      Resolution    Test Current   Accuracy    Temp.Coe.0℃-18℃;28℃-50℃        

                    3.0000 V       100μV          1 mA       0.010+0.020   0.001+0.002 

           Med     10.0000 V       100μV         100μA       0.010+0.020   0.001+0.002 

                   10.0000 V       100μV          10μA       0.010+0.020   0.001+0.002 

Maximum Input Protection: 1000VDC or 750VAC for all ranges.

                                      

TRUE RMS AC VOLTAGE AND CURRENT CHARACTERISTICS

ACCURACY: ±(% of reading + % of range),23℃±5℃.

●  AC Voltage  

  Rate     Range    Resolution         Accuracy(1 year)(1) 23℃±5℃

                                                      10~20 Hz      20~50 Hz      50~100Hz     100~20kHz

 

          100.0000mV    0.1 μV          1.50+0.20     0.50+0.10    0.10+0.03     0.05+0.03

          1.000000 V    1 μV            1.50+0.20     0.50+0.10    0.10+0.03     0.05+0.03

Slow   10.00000 V    10 μV           1.50+0.20     0.50+0.10    0.10+0.03     0.05+0.03

          100.0000 V    100μV           1.50+0.20     0.50+0.10    0.10+0.03     0.08+0.03

          750.000 V (2) 1 mV            1.50+0.20     0.50+0.10    0.10+0.03     0.08+0.03

          100.000 mV    1 μV            1.50+0.20     0.50+0.10    0.10+0.03     0.05+0.03

          1.00000  V    10 μV           1.50+0.20     0.50+0.10    0.10+0.03     0.05+0.03

 Med     10.0000  V    100 μV          1.50+0.20     0.50+0.10    0.10+0.03     0.05+0.03

          100.000  V    1 mV            1.50+0.20     0.50+0.10    0.10+0.03     0.08+0.03

          750.00 V (2)  10 mV           1.50+0.20     0.50+0.10    0.10+0.03     0.08+0.03

          100.00 mV     10 μV                                      0.20+0.05     0.10+0.05

          1.0000  V     100 μV                                     0.20+0.05     0.10+0.05 

 Fast    10.000  V     1 mV                                       0.20+0.05     0.10+0.05

          100.00  V     10 mV                                      0.20+0.05     0.12+0.05

          750.0  V (2)  100 mV                                     0.20+0.05     0.12+0.05

 TemperatureCoefficient

                                       0.100+0.004   0.035+0.004   0.005+0.004  0.005+0.004

 0℃-18℃ & 28℃-50℃

 

  Rate      Range         Resolution               Accuracy(1 year) (1) 23℃±5℃

                                                                   20~50 kHz           50~100kHz           100~300kHz

 

            100.0000mV       0.1 μV                 0.15+0.05           0.60+0.08           4.00+0.50

            1.000000 V       1 μV                   0.11+0.05           0.60+0.08           4.00+0.50

  Slow     10.00000 V       10 μV                  0.11+0.05           0.60+0.08           4.00+0.50

            100.0000 V       100μV                  0.18+0.05          0.6+0.08             ---------                      

           750.000 V(2)         1 mV                   ---------          ---------            ---------

            100.000 mV       1 μV                   0.15+0.05           0.60+0.08           4.00+0.50

            1.00000    V     10 μV                  0.11+0.05           0.60+0.08           4.00+0.50

   Med      10.0000    V     100 μV                 0.11+0.05           0.60+0.08           4.00+0.50

            100.000    V     1 mV                   0.18+0.05          0.6+0.08             ---------

           750.00 V (2)       10 mV                  ---------          ---------            ---------

            100.00 mV        10 μV                  0.25+0.05           0.60+0.08           4.00+0.50

            1.0000   V       100 μV                 0.25+0.05           0.60+0.08           4.00+0.50

   Fast     10.000   V       1 mV                   0.25+0.05           0.60+0.08           4.00+0.50

            100.00   V       10 mV                  0.25+0.05           0.60+0.08           ---------

           750.0    V (2)       100 mV                 ---------          ---------            ---------

  TemperatureCoefficient

                                                 0.011+0.005          0.060+0.008           0.20+0.02

  0℃-18℃ & 28℃-50℃

(1)  Specified accuracy at input >5% of the range.

(2)  1% over-range (757.50 V) is readable at 750V range.

Measurement method: True RMS measurement

Maximum Crest factor: 3.0 at full scale

Maximum input voltage: 750Vrms

                       ≤3×10-7 Volt-Hz for all ranges

Input impedance: 1MΩ±2% in parallel with capacitance <100pF

Maximum DCV: 500V for all AC ranges

                

●  AC Current (True RMS, AC Coupling)

 Rate     Range     Resolution           Accuracy(1 year)(1) 23℃±5℃

                                                        10~20 Hz        20~50 Hz      50~100Hz

 

         10.00000mA     10 nA           1.50+0.10      0.50+0.03      0.10+0.03

Slow    1.000000 A     1 μA            1.50+0.10      0.05+0.03      0.12+0.03

         10.00000 A     10 μA           1.60+0.10      0.60+0.30      0.15+0.03

         10.0000mA      100nA           1.00+0.20      0.50+0.05      0.10+0.05

 Med    1.00000 A      10 μA           1.00+0.20      0.50+0.05      0.12+0.05

         10.0000 A      100 μA          1.00+0.20      0.50+0.05      0.15+0.05

         10.000mA       1 μA                                          0.20+0.05

 Fast   1.0000 A       10 μA                                         0.20+0.05

         10.000 A       100 μA                                        0.20+0.05

 TemperatureCoefficient

                                         0.100+0.006  0.05+0.006    0.035+0.006

 0℃-18℃ & 28 ℃-50℃

 

 Rate     Range   Resolution               Accuracy(1 year)(1) 23℃±5℃

                                                          100~2kHz          2k~5k Hz       5k~10kHz

         10.00000mA      10 nA             0.05+0.03      0.10+0.03         0.20+0.03 

 Slow    1.000000 A      1 μA              0.10+0.04      0.50+0.03         2.00+0.10

         10.00000 A      10 μA             0.12+0.04      0.60+0.05         2.50+0.10

         10.0000mA       100nA             0.05+0.05      0.50+0.05         0.20+0.05

  Med    1.00000 A       10 μA             0.10+0.06      0.50+0.05         2.00+0.20

         10.0000 A       100μA             0.12+0.06      0.60+0.10         2.50+0.20

         10.000mA        1 μA              0.20+0.10      1.00+0.10         0.50+0.08

  Fast   1.0000 A        10μA              0.20+0.10      1.00+0.10         4.00+0.30

         10.000 A        100μA             0.20+0.10      1.00+0.10         5.00+0.30

 TemperatureCoefficient

                                        0.015+0.006       0.015+0.006    0.100+0.006

 0℃-18℃ & 28 ℃-50℃

(1) Specified accuracy at input >5% of the range

 

True Rms AC Current

Shunt:     10.1Ω at 10mA range,0.1Ω at 1A and 0.01Ω at 3A ranges.

Burden voltage:     10mA    Range: <0.15 Vrms

                                1A   Range:      <0.3 Vrms

                             10A   Range:       < 0.15 Vrms

Measurement method: True RMS measurement

Maximum Crest factor: 3.0 at full scale

Maximum Input and Overload Current Protection: 2A/ 250V fuse.

 

FREQUENCY AND PERIOD CHARACTERISTICS

CONDITIONS: SLOW RATE (GATE TIME 1 Sec)

ACCURACY: ±( % of reading)

 

● Frequency 


   ACV       Frequency                       Full Scale                 Input Sensitivity

                  Resolution                                      Accuracy(2)

  Range       Range                           Reading                         (Sine Wave)

 

            5-10 Hz             1μHz           9.999,999      0.05        200mVrms

  100mV

            10-100Hz           10μHz          99.999,99       0.01        40mVrms

    to

            100-100 kHz        10mHz          999.999,9        0.005       40mVrms

  750V

            100k-1MHz(1)       100mHz         999.999,9        0.005       100mVrms

 

● Period

   ACV       Frequency                         Full Scale                  Input Sensitivity

                  Resolution                                        Accuracy(2)

  Range         Range                          Reading                          (Sine Wave)

            1~10μs (1)        0.001ns        9.999,999           0.005        100mVrms

  100mV

            10μs~10ms         0.1ns          9.999,999           0.005       40mVrms

    to

            10ms~100ms        0.1μs          99.999,99            0.01       40mVrms

  750V

            100ms~200ms       1μs             199.999,9           0.05       200mVrms

 

     Maximum Crest factor: 3.0 at full scale

     Maximum input voltage: 750Vrms

                               ≤3×107 Volt-Hz for all ranges

     Input impedance: 1MΩ±2% in parallel with capacitance <100pF

     Maximum DCV: 500V for all AC ranges

 

Measure Characteristics

Gate Time: 10ms,100ms,or 1 sec。

(1) If tested frequency is greater than 1MHz, it will be displayed but no specified accuracy is guaranteed

(2) Specified accuracy at input >5% of range. 

                      

Measuring rate

Maximum rate under internal trigger mode: 1000 meas/sec

Maximum rate under external trigger mode: 1000 meas/sec(measurement results are stored in the

internal memory)

 

Triggering and Memory

Reading hold sensitivity: 0.01%, 0.1%, 1% or 10% of reading

Trigger Delay: 0 to 6000ms (1 ms step size)

Memory: 512 readings can be stored

 

Math Functions

Rel, Max/Min/Average/StdDev (of stored reading), dBm, dB, Limit Test, % and mX+b

dBm Reference Resistance: 1Ω to 9999Ω (1Ω step size), default is 75Ω

 

Standard Programming Languages

SCPI (Standard Commands for Programmable Instruments )

 

Remote Interface:

Optional GPIB(IEEE-488.2) and RS-232C

 

General Specifications:

Power Supply: 110/220V±10%

Power Line Frequency: 50/60Hz ±5%

Power Consumption: ≤ 20VA

Operating Environment: 0℃ to 40 ℃, ≤90%RH,

Storage Environment: -40℃ to 70 ℃

Warm-up: more than 30mins

Dimensions (W×H×D): 225mm×100mm×355mm