Product Name: DC 5V 12V 24V Multifunction Latching Relay PLC Cycle Timer Delay Switch Module
 
 
 
Package inlcuded:
1 PCS 1channel DC 5V/12V/24V Multifunction Relay Module
 

Description:

Latching Relay:
Working voltage: DC 12V(10-15V)
Working current : 7-8MA(Digital Tube is OFF)
Working current : 28-30MA(Digital Tube is ON)
Relay switching current: 45MA (only lasts 0.3 seconds)
D1 LED : Relay status indication: ON relay is on, OFF relay is off
PWR LED: Input indicator,It will flash when power on or trigger.

Ordinary relay:
Working current(Digital Tube is OFF) : 8MA(Relay OFF),40MA(Relay ON)
Working current(Digital Tube is ON)   : 34MA(Relay OFF),60MA(Relay ON)


Load current : AC 250V/10A, DC 30V/10A
0.1 seconds -270 hours between adjustable
18 functions can be selected(Function compatible with CE030 FRM01 Relay Module)
Size : 76 x 40 x 20mm
Weight : 28g


Use must read:

1 For more instructions, please contact me, or search for ''CE030/FRM01/LR43A01'' on GOOGLE. Their functional parameters are the same.

2 Energy saving is relative to ordinary relay modules.


3 In the working state, click the SET button to close the digital display, and click again to open the digital tube display.

4 Press and hold the NUM+ button for 4-5 seconds. After 10 seconds, enter the energy-saving mode. Press and hold the NUM+ button again for 4-5 seconds to exit the energy-saving mode (this function can only be set when the digital tube is lit).

Typical applications:

Automotive electronics
Industrial automation and control
Industrial equipment
Motor LED PLC
IP Camera PTZ CCTV
UPS Uninterruptible power supply
Smart Home
Emergency lighting
MCU development board
Toy car
Home lighting system
Remote control switch
Remote locking
Smart Home / Home Automation
LED lighting
Fluorescent lamp
DC Motor
Fluorescent lamp
Automotive electronics


Connections:
Module control side: there are 3-wire interface, all interfaces are terminal
1, DC +:power positive
2, DC-: power in negative
3, CH1: Input Detection Interface
Relay outputs: a 3-wire interface, all interfaces are terminal
1, NO: normal open (before relay closes, this pin is not connected. after relay closes, the pin short-connects with COM)
2, COM: Relay Common Interface
Module Functions:
Tips: Function 1-8 on power-up self-start function 9-18 require low pulse signa l (low duration is shorter than 20ms, hereinafter the same) trigger the start.
 
Function 1:
Timing Pick: After power, time delay relay pull T1, T1 between 0.1 seconds -270 hours adjustable, CH1 interface to a low level pulse signal, repeat the above functions;
 
Function 2:
Timing off: when the power relay, time delay relay disconnected T1, T1 between 0.1 seconds -270 hours adjustable, CH1 interface to a low level pulse signal, repeat the above functions;
 
Function 3:
 
Timing pull off again: After power relay to not pull, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 in 0.1 seconds -270 hours between adjustable, CH1 interface to a
low pulse signal, repeat the above functions;
 
Function 4:
Timing and then pull off: After power, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, -270 hour in 0.1 seconds delay time between T1 and T2 adjustable to CH1 interface a low pulse signal, repeat the above functions;
 
Function 5:
Infinite loop timing mode 1: After power relay to not pull, after the delay time T1 reaches the relay is energized; pull the relay off after time T2 arrives, and then repeat the above condition, the delay time T1 and T2 at 0.1 adjustable between second -270 hours, giving a low level pulse signal CH1 interface, you can restart the above functions;
 
Function 6:
Infinite loop timing mode 2: After power, immediately pull the relay delay time T1 reaches the relay off; arrive after disconnecting time T2 relay, and then repeat the above condition, the delay time T1 and T2 in 0.1 seconds adjustable between -270 hours, giving a low level pulse signal CH1 interface, you can restart the above functions;
 
Function 7:
Finite loop timing mode 1: 5 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a low pulse signal, the above functions can be re-started;
 
Function 8:
Finite loop timing mode 2: 6, on the basis of the function, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a low pulse signal, the above functions can be re-started;
 
Function 9:
Latching relay modes: CH1 interface to relay a low level pulse signal, relay, give a low pulse signal relay disconnected.
 
Function 10:
Trigger relay modes: CH1 interface to a low signal relay, relay, low disappear, relay disconnected.
 
Function 11:
Pull the trigger timing: After power relay does not act, a low-level interface to CH1 pulse signal, the delay time relay pull T1, T1 between 0.1 seconds -270 hours adjustable, repeating a low level interface to CH1 pulse signal, repeat the above function;
 
Function 12:
Trigger timing off: After power relay does not act, a low-level interface to CH1 pulse signal relay, the relay off delay time T1, T1 between 0.1 seconds -270 hours adjustable, repeat to CH1 interface a low pulse signal, repeat the above functions;
 
Function 13:
Pull the trigger timing then disconnect: After power relay does not act, CH1 interface to a low level pulse signal, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 between 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, repeat the above functions;
 
Function 14:
Disconnect and then pull the trigger timing: After power relay does not act, a low-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, repeat the above functions;
 
Function 15:
Infinite loop timing mode 1: After power relay does not operate to a low level pulse signal CH1 interface, the delay time T1 reaches the relay is energized; pull off the relay arrival time T2, and then repeat the above condition, the extension when the time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, the above functions can be re-started;
 
Function 16:
Infinite loop timing mode 2: After power relay does not act, a low-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; break time T2 after reaching relay, then repeat the above condition, the delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, the above functions can be re-started;
 
Function 17:
Finite loop timing mode 1: 15 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a low pulse signal, the above functions can be re-started;
 
Function 18:
Finite loop timing mode 2: 16 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a low pulse signal, the above functions can be re-started;
 
 
 
Module Size
1. Dimensions : 76mm *40mm * 20mm (L* W * H);
2. Screw Size: 3.0mm.
3. Screw holes center distance: 69mm * 33mm