Typial application :
1. Reading status(reading the satus of the relay (on/off))
Channel 1 :55 56 00 00 00 01 00 AC
Channel 2 :55 56 00 00 00 02 00 AD
Channel 3 :55 56 00 00 00 03 00 AE
Channel 4 :55 56 00 00 00 04 00 AF
2. Relay open (issue this command ,Relay open , COM connect to NO )
Channel 1 :55 56 00 00 00 01 01 AD
Channel 2 :55 56 00 00 00 02 01 AE
Channel 3 :55 56 00 00 00 03 01 AF
Channel 4 :55 56 00 00 00 04 01 B0
3. Relay close (issue this command ,Relay close , COM disconnect NO , and COM connect to NC )
Channel 1 :55 56 00 00 00 01 02 AE
Channel 2 :55 56 00 00 00 02 02 AF
Channel 3 :55 56 00 00 00 03 02 B0
Channel 4 :55 56 00 00 00 04 02 B1
4. Relay toggle(Relay status reversal,if COM connect to NO,this commands will Disconnect COM to NO and Reverse COM connect to NC,and vice versa)
Channel 1 :55 56 00 00 00 01 03 AF
Channel 2 :55 56 00 00 00 02 03 B0
Channel 3 :55 56 00 00 00 03 03 B1
Channel 4 :55 56 00 00 00 04 03 B2
5. Relay momentary(Relay COM connect to NO,disconnect after 200MS )
Channel 1 :55 56 00 00 00 01 04 B0
Channel 2 :55 56 00 00 00 02 04 B1
Channel 3 :55 56 00 00 00 03 04 B2
Channel 4 :55 56 00 00 00 04 04 B3
6.Relay Interlock
Channel 1 :55 56 00 00 00 01 05 B1
Channel 2 :55 56 00 00 00 02 05 B2
Channel 3 :55 56 00 00 00 03 05 B3
Channel 4 :55 56 00 00 00 04 05 B4
Once issue a command, will have a return fame , 7th byte of return fame mean the satus of realy .
1.Return relay open(return this command,mean COM connect to NO )
Channel 1 :33 3C 00 00 00 01 01 71
Channel 2 :33 3C 00 00 00 02 01 72
Channel 3 :33 3C 00 00 00 03 01 73
Channel 4 :33 3C 00 00 00 04 01 74
2.Return relay close(return this command,mean COM disconnect NO , and COM connect to NC )
Channel 1 :33 3C 00 00 00 01 02 72
Channel 2 :33 3C 00 00 00 02 02 73
Channel 3 :33 3C 00 00 00 03 02 74
Channel 4 :33 3C 00 00 00 04 02 75