Model
|
MS-F07
|
Input conditions
|
Input voltage
|
85 to 264 VAC (50/60 Hz), 120 to 340 VDC*1
|
Frequency
|
47 to 63Hz*2
|
Inputconditions
|
Input current (100/200 VAC)
|
0.28/0.16A or less
|
Efficiency (100/200 VAC)
|
―
|
Leakage current (100/200 VAC)
|
0.5/1mA or less
|
Rush current (100/200 VAC)
|
18, 36 A or less (with a +25°C 77°F cold start)
|
Output characteristics
|
Rated voltage
|
12V
|
Variable voltage range
|
±5% (with V.ADJ)
|
Rated current
|
0.65A
|
Ripple/noise voltage
|
2% (p-p) or less
|
Input fluctuation
|
0.5% or less
|
Load fluctuation
|
1.0% or less
|
Temperature fluctuation
|
―
|
Startup time
|
400ms or less
|
Output holding time
|
20 ms or more (100 to 240 VAC)
|
Protection
|
Overcurrent protection
|
Constant current drop method, automatic recovery, 0.79 A or more
|
Overvoltage protection
|
Present*3
|
Display
|
Display power
|
―
|
Power off memory time
|
Display resolution
|
Applicable standards
|
Safety standards
|
UL60950, CSA C22.2 number 60950, EN60950
|
EMC standard
|
FCC Part 15 B Class A, EN55011 Class A
|
Limits for harmonic current emissions
|
EN61000-3-2*4
|
Other
|
Parallel operation
|
Not possible
|
Series operation
|
Possible*5
|
Cooling method
|
Natural air cooling
|
Environmental resistance
|
Insulation resistance
|
100 MΩ or more at 500 VDC
(between input and output, between input and FG, and between output and FG)
|
Ambient temperature
|
-10 to +60 °C 14 to 140 °F (No freezing) (see the derating characteristics)
|
Relative humidity
|
25 to 85 % RH (No condensation)
|
Withstand voltage
|
3.0 kVAC 50/60 Hz 1 min (across input and output terminals), 2.0 kVAC 50/60 Hz 1min (across input terminals and PE terminal), 500 VDC 1min (across output terminals and PE terminal)
|
Vibration resistance
|
10 to 57 Hz, Double amplitude 0.3 mm 0.01", 57 to 500 Hz, 19.6 m/s2 (2 G), cycle: 5.5 minutes, 2 hours in each of the X, Y, and Z directions
|
Shock resistance
|
Peak acceleration: 300 m/s2, 2 times in each of the X, Y, and Z directions
|
Weight
|
Approx. 140 g
|
*1 When applying for safety standards are 100 to 240 VAC, 50/60 Hz.
*2 The rated input voltage and rated frequency when applying for safety standards are 100 to 240 VAC, 50/60 Hz.
*3 To return, turn OFF the input power supply and after leaving it off for 1 minute or more, plug in the input power supply again. The E/F Series is a Zener diode clamp type. It will not restart after the protection circuit operation.
*4 For the MS2-H100, this is applicable only when the load ratio is 70% or less.
*5 The applicable standards do not apply for parallel and serial operations.
|