Model
|
EX-110V*1
|
Type
|
Sensor head
|
Amplifier unit
|
NPN: EX-V02
PNP: EX-V02P
|
Shape
|
M10 x 18 mm
0.71" Threaded
|
Measuring range
|
0 to 2 mm 0 to 0.08"
|
Display range
|
-19,999 to +19,999
|
Linearity
|
±0.3% of F.S.
|
Resolution (No. of averaging
measurements: 64)
|
0.4 μm
|
Sampling rate
|
40,000 samplings max./sec. *2
|
Display speed
|
20 times/sec.
|
Display power
|
7-segment 2-color LED
|
Over-range alarm
|
±FFFF is displayed.
|
Control input
|
NPN open-collector or non-voltage contact (Timing input, Reset input, Auto-zero input, Comparator output disable input, Synchronous input, External setting input)/PNP: Applied voltage; 10 to 30 V
|
Control output
|
Setting method
|
Upper/lower 2-level setting x 4 patterns (selectable)
|
Signal
|
NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.)
PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.)
|
Response time
|
0.075 ms (at maximum speed)
|
OFF-delay time
|
60 ms
|
Strobe output
|
NPN: 100 mA max. (40 V max.)/PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.)
|
Alarm output
|
NPN: 100 mA max. (40 V max.)/PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.)
|
Analog output voltage
|
Output voltage
|
±5V
|
Impedance
|
100 Ω
|
Response time
|
0.075 ms (at maximum speed)
|
Temperature characteristics
|
0.07% of F.S./°C *3
|
Major functions
|
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc.
|
Rating
|
Power voltage
|
24 VDC ±10%, Ripple (P-P): 10% max.
|
Current consumption
|
240 mA max.
|
Environmental resistance
|
Ambient temperature
|
-10 to +60 °C 14 to 140 °F, No freezing
|
Relative humidity
|
35 to 85%, No condensation
|
Vibration resistance
|
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions
|
Weight
|
Approx. 55 g (including 3 m 9.8' cable)
|
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials.
*2 When the digital filter function is used, the sampling rate is 20,000 sampling/sec.
*3 When the distance between the sensor head and the target is within 50% of the measuring range.
|