Rated voltage frequency: AC 220V/50Hz

Voltage adaptation range: 100V~260V

Rated power: 5KW (power adjustable range is 20~100%)

Temperature: -20℃~50℃

Humidity: ≤95%

 

 

 

Basic performance:


1. Voltage and power characteristics: 210 ~ 260V constant power output;

2. Thermal efficiency ≥95%;

3. IGBT overheating protection temperature: 85±5℃;

4. Working frequency: 5~40KHz;

5. Using industrial-grade high-reliability AVR high-speed computing processor, half-bridge series resonance;

6. Using highly reliable digital phase-locked loop control technology, digital stepless adjustment to achieve 20% ~ 100% adjustable power, and also compatible with 0 ~ 5VDC and 4 ~ 20mA analog PID control power output;

7. It has a completely electrically isolated soft start heating/stop mode control interface, which is convenient for connecting with the thermostat; has a 12V/24V input start/stop mode control interface, which is convenient for connecting with various solid state relays (with voltage input work, otherwise the heating is stopped) ), the speed of control response is fast, the start time is less than 1S;

8. With short-circuit and open-circuit protection of the heating coil, 130% overload and no-load instantaneous protection, protection response time ≤ 2uS;

9. Add a load temperature detection interface, connect the thermistor, the detection temperature range is 0 ~ 150 ℃, the accuracy reaches ± 1 ℃;

10. Wide coil compatibility, can be compatible to replace the same model products of other companies;

11. Strong anti-interference ability, high-reliability electrical isolation for soft start, 30 controllers can be simultaneously controlled on the same heating body to start/stop without interference with each other;

12. Open application platform, users can use our dedicated digital programming display to automatically read important parameters such as current, frequency, phase difference, temperature, etc., and can also set various application parameters according to needs, making installation and debugging more simple and convenient;

13. The working time can be set from 1 to 255 days, it will be automatically closed after the time is over, and you need to enter the password to restart;

14. Using industrial-grade components, 100% high temperature aging test to ensure long-term continuous and reliable work in a 50 ℃ industrial environment for 24 hours, service life ≥ 50000Hrs;

15. Product standard delivery: integration of control board and radiator, 1 industrial indicator light;

16. Size: 225X220X110, must be equipped with a cooling fan (220V/150mm or 24V/500mA DC fan);

 


 

1. Three indicator lights, power indicator light Power and work light (two work lights Work, one board, one external connection), Power and Work light at the same time during normal work, Work work indicator light when in stop working or protection state Shining

2. Soft Boot This terminal is used to start/stop. It is working when it is closed; it is stopped when it is open.

Note: There is a shorting plate next to the green socket (Soft Boot terminal). The socket has the same function as the green socket. If the green socket is used for control, the shorting plate must be removed. If the shorting plate is not removed, there is no need to connect the green socket. It will start automatically when the board is powered on;

3. AC-L and AC-N are 220V power input, OUT1 and OUT2 are output terminals connected to the heating coil;

4. Please pay attention to the installation, the radiator is live! Don't touch the shell! The shell must be reliably grounded;

5. Coil reference parameters:

Mica wrapped glass fiber braided high temperature resistant cable, cross-section national standard 8 ~ 10mm2 inductance is 60 ~ 80uH, about 12 ~ 15m (excluding lead length) is required, the thickness after insulation cotton is required to be compressed is: tubular coil: 15 ~25mm, flat coil: 10~15mm, rated working current: 20~22A, general working frequency: 10K~20KHZ.