OVERVIEW Brand: DELL-APC Model: DLRT8000RMXLI6U Condition: Used APC Smart UPS RT 8000VA 230V DURT8000RMXL16U DELL 208V 220V 240V Very Good Full Working Condition
DLRT8000RMXLI6U
APC / IBM SMART-UPS RT 8000VA 4200W RM 3U 230V APC Smart-UPS RT 8000VA 4200W RM 3U 200-240V Model: DLRT8000RMXLI6U | Input: NEMA L6-30P | Output: (2) IEC 320 C19, (8) IEC 320 C13 | Double Conversion Online UPS - Sinewave Output Comes with APC AP9631 UPS 10/100Mbps SNMP Network Management Card |
These are Dell badges UPS made by APC ..
comes with front Cover, Rails are not included
|
|
---|
Main Input Voltage | 230 V 400 V 3 phases |
---|
Other Input Voltage | 220 V 240 V |
---|
Main Output Voltage | 230 V |
---|
Other Output Voltage | 220 V 240 V |
---|
rated power in W | 6400 W |
---|
Rated power in VA | 8000 VA |
---|
output connection type | 4 IEC 60320 C13 6 IEC Jumpers 4 IEC 60320 C19 |
---|
Output connector type | Hard wire 3-wire (H N + E) 1 |
---|
Number of rack unit | 6U |
---|
Battery type | Lead-acid battery |
---|
GeneralNumber of power module free slots | 0 |
---|
Number of power module filled slots | 0 |
---|
Redundant | No |
---|
PhysicalColour | Black |
---|
Height | 26.3 cm |
---|
Width | 43.2 cm |
---|
Depth | 73.6 cm |
---|
Net weight | 110.92 kg |
---|
Mounting location | Front |
---|
Mounting preference | Lower |
---|
Mounting mode | Rack-mounted |
---|
Two post mountable | 0 |
---|
USB compatible | No |
---|
InputNetwork frequency | 50/60 Hz +/- 5 Hz auto-sensing |
---|
Number of input connectors | 1 hard wire 3-wire (1P + N + E) 1 hard wire 5-wire (3P + N + E) |
---|
Input voltage limits | 160...280 V |
---|
Input harmonic distortion | Less than 7 % for full load |
---|
OutputMaximum configurable power in W | 6400 W |
---|
Harmonic distortion | Less than 3 % |
---|
Output frequency | 50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz sync to mains |
---|
Crest factor | 3 : 1 |
---|
UPS type | Double conversion online |
---|
Wave type | Sine wave |
---|
bypass type | Internal bypass (automatic and manual) |
---|
Efficiency | 93 % (full load) |
---|
Maximum configurable power in VA | 8000 VA |
---|
ConformanceProduct certifications | C-Tick CE GOST VDE |
---|
EnvironmentalAmbient air temperature for operation | 0…40 °C |
---|
Relative humidity | 0…95 % non-condensing |
---|
Operating altitude | 0...10000 ft |
---|
Ambient air temperature for storage | -15…45 °C |
---|
Storage Relative Humidity | 0…95 % non-condensing |
---|
Storage altitude | 0.00…15240.00 m |
---|
Acoustic level | 55 dBA |
---|
heat dissipation | 1603 Btu/h |
---|
IP degree of protection | IP20 |
---|
Communications & ManagementFree slots | 0 |
---|
Preinstalled device | Network management card 2 with environmental monitoring |
---|
Alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
---|
Emergency power off | Yes |
---|
Surge Protection and FilteringSurge energy rate | 1265 J |
---|
Noise suppression | Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 |
---|
*Above mentioned specifications are from manufacturers website
CONTENTS:
- 1 x DLRT800RMXLI6U APC Smart-UPS RT 8000VA, 230/400V, rackmount, 6U,
- 1x APC AP9631 UPS 10/100Mbps SNMP Network Management Card
- 4 x Batteries (installed) Tested working
*WHAT YOU SEE IS WHAT YOU GET |