Yilink Batteria LifePo4 4.8Kw 100A 48v versione Rack 4U
Dotata di proprio BMS, può essere utilizzata con qualsiasi inverter a 48v. Possibilità di collegamento cavo di comunicazione BMS con gli inverter Voltronic (tutti i modelli dotati di porta BMS) quali Axpert King, Vm III, Vm IV, Mks III, Mks IV, Axpert Max (tutti i modelli 48v) e Max II
Battery Pack Parameters
No.
|
Items
|
General Parameter
|
Remark
|
1
|
Combination method
|
15S
|
|
2
|
Nominal Voltage
|
48V
|
|
3
|
Rated Capacity
|
Typical
|
100Ah
|
|
Minimum
|
100Ah
|
4
|
Energy
|
4800Wh
|
|
5
|
Factory Voltage
|
48~51V
|
Mean Operation Voltage
|
6
|
Voltage at end of Discharge
|
37.5~42V
|
Discharge Cut-off Voltage
|
7
|
Voltage at end of Charge
|
52.5~55.5V
|
Charge Cut-off Voltage
|
8
|
Standard charge
|
Constant Current 20A Constant Voltage see No.7
0.02CA cut-off
|
Charge time : Approx 5~6 h
|
9
|
Limiting current
|
20A
|
BMS Limited (Charge current is
≥100A to open the current Limit)
|
10
|
Standard discharge
|
Constant current:20A end voltage see NO.6
|
|
11
|
Maximum Continuous Charge Current
|
100A
|
50ºC≥T≥5ºC
|
12
|
Maximum Continuous Discharge Current
|
100A
|
55ºC≥T≥0ºC
|
13
|
Operation Temperature Range
|
Charge:0~55℃
|
60±25%R.H.
No matter what mode the battery is in, once the temperature is found to exceed the absolute temperature range, stop charging or discharging immediately
|
Discharge:-20~60℃
|
14
|
Storage Temperature Range
|
Less than 6 months: -10~35℃
|
60±25%R.H.
at the shipment state
|
Less than 3 months: -10~45℃
|
Less than 1 months: -20~55℃
|
15
|
Dimensions(W*D*H)
|
442*480*178mm
|
Include case
|
16
|
Net Weight
|
46Kg
|
Include case
|
17
|
Internal Impedance
|
≤45mΩ
|
Internal resistance measured at AC 1KHZ after 50% charge.
The measure must uses the new batteries that within one week after shipment and cycles less than 5
times.
|
Battery Management System
Function
|
Alarm
|
Cell over-charge voltage
|
Cell charge low temperature
|
Cell over-discharge voltage
|
Cell charge over temperature
|
Pack over-charge voltage
|
Cell discharge low temperature
|
Pack over-discharge voltage
|
Cell discharge over temperature
|
Over-current charge
|
Environment low temperature
|
Over-current discharge
|
Environment over temperature
|
Mos over temperature
|
|
Protection
|
Cell over-charge voltage
|
Cell charge over temperature
|
Cell over-discharge voltage
|
Cell discharge low temperature
|
Pack over-charge voltage
|
Cell discharge over temperature
|
Pack over-discharge voltage
|
Environment low temperature
|
Over-current charge
|
Environment over temperature
|
Over-current discharge
|
Short circuit
|
Mos over temperature
|
Fault
|
Cell charge low temperature
|
|
Others
|
Cell balance function
|
Communicate function
|
Total capacity function
|
Storage history function
|
Current limiting function
|
Dry contact function
|
No.
|
Items
|
Description
|
1
|
+ Power terminal
|
Power cable terminals: one connect to equipment, the other
one paralleling to other battery module for capacity expanding
|
2
|
- Power terminal
|
3
|
LCD Screen
|
Display the battery’s data
|
4
|
Power Switch
|
To turn ON/OFF while battery
|
5
|
Working indicator light
|
Display state information
|
6
|
ALM alarm indicator light
|
Red-trouble-light on
|
7
|
Capacity volume indicator
|
Display the battery's capacity
|
8
|
Reset Key
|
Sleep /Activation /Reset
|
9
|
ADS Dialer
|
4 ADD switches, to definite different address code for each battery module when multiple modules are cascaded, up to 15
addresses.
|
10
|
Dry Contact Terminal
|
1/2 Normally open, closed during fault protection;
3/4 Normally open, closed when a low battery alarm
|
11
|
RS485
|
RJ45 Port,used to connect to the inverter's RS485 port
|
12
|
CAN
|
RJ45 Port,used to connect to the inverter's CAN port
|
13
|
RS232
|
RJ11 Port,used battery condition monitoring or manufacturer to
debug or service
|
14/15
|
RS485
|
RJ45 Port,used communication in parallel
|
16
|
Grounding Point
|
Safety
|
Attenzione il prezzo di vendita di questi prodotti è con IVA al 10% in caso di acquisto dovrete compilare una dichiarazione che i prodotti verranno utilizzati per un impianto ad energie rinnovabili Il prodotto è vendibile con iva ridotta al 10% esclusivamente a residenti italiani con spedizione in italia. In caso di clienti esteri prego visitare la sezione del sito Inverter for EU countries e una volta registrati e loggati il sito visualizzerà il prezzo con l'aliquota iva del paese di destinazione IL MODULO LO TROVATE QUI https://www.cercastock.it/repository/_barba_srl_dich_10.pdf IL PRODOTTO NON POTRA' ESSERE SPEDITO FINO ALLA RICEZIONE DEL MODULO COMPILATO ALL'INDIRIZZO EMAIL ebay.barbasrl@gmail.com o per fax allo 0545030125 Per i clienti italiani che vogliono procedere all'acquisto senza la compilazione del modulo con aliquota standard del 22% si prega di inviare una mail all'indirizzo cercastock@cercastock.it |