Condition:

 Original Packaging
Open Box - Only To Check Quality Of Inventory & Take Photos
Manufacturer Refirbished - See Packing Slip

 

Included:

1x  FG2105-05-B NetLinx NI-3100 And Axcent3 Integrated Controller w/Mount

 

Specs:


NI-3100 Specifications
Models Available: • NI-3100 64MB Controller (FG2105-05)
• NI-3100/256 256MB Controller (FG2105-25)
Note: The NI-3100 & NI-3100/256 can be upgraded to provide one
ICSHub and two ICSNet ports by installing the optional ICSNet daughter
card (FG2105-10 - see Other AMX Equipment).
• NI-3100/ICS 64MB Controller with ICSNet (FG2105-15)
• NI-3100/256/ICS 256MB Controller with ICSNet (FG2105-35)
Dimensions
(HWD):
• 3 1/2" x 17" x 3 1/2" (8.8 cm x 43.2 cm x 8.8 cm)
• RU: 2
Power
Requirement:
900 mA @ 12 VDC
Memory: NI-3100 & NI-3100/ICS:
• 64 MB SDRAM
• 1 MB Non-volatile (NV) SRAM
NI-3100/256 & NI-3100/256/ICS:
• 256 MB SDRAM
• 1 MB Non-volatile (NV) SRAM
Compact Flash: 2GB or greater (upgradeable to 4GB - see Other AMX Equipment).
Note: AMX may increase Flash size at any time in response to market
availability.
Weight: 4.55 lbs (2.06 kg)
Enclosure: Metal with black matte finish
Certifications: FCC Part 15 Class B, CE, and IEC 60950
Front Panel LEDs:
LINK/ACT
(green):
Blinks when the Ethernet cables are connected and terminated correctly.
Also blinks when receiving Ethernet data packets.
Status (green): Blinks to indicate that the system is programmed and communicating prop-
erly.
Output (red): Blinks when the Controller transmits data, sets channels On and Off, sends
data strings, etc.
Input (yellow): Blinks when the Controller receives data from button pushes, strings, com-
mands, channel levels, etc.
RS-232/422/485
(red / yellow):
Light to indicate that DB9 Ports 1 - 7 are transmitting or receiving RS-232,
422, or 485 data (red = TX, yellow = RX).
Relay (red): Light to indicate the relay channels 1 - 8 are active (closed). These LEDs
reflect the state of the relay on Port 8
NI-3100 Specifications (Cont.)
Front Panel LEDs (Cont.):
IR/Serial (red): Light to indicate the IR/Serial channels 1 - 8 are transmitting control data on
Ports 9 - 16. LED indictor for each IR port remains lit for the length of time
that IR/Serial data is being generated.
I/O (yellow): Lights when the rear I/O channels 1 - 8 are active. The LED for each I/O port
reflects the state of that particular port.
Rear Panel Components:
RS-232/422/485
(Ports 1 - 7):
7 RS-232/422/485 control ports using DB9 (male) connectors with XON/
XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to send), and
300-115,200 baud.
ICSNet: 2 RJ-45 connectors for ICSNet interface (provided by optional
ICSNet daughter card).
ICSHub Out: RJ-45 connector provides data to a Hub connected to the Controller (pro-
vided by optional ICSNet daughter card).
Relay (Port 8): • 8-channel single-pole single-throw relay ports
• Each relay is independently controlled.
• Supports up to 8 independent external relay devices
• Channel range = 1-8
• Each relay can switch up to 24 VDC or 28 VAC @ 1 A
• Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide relay
termination
Digital I/O
(Port 17):
8-channel binary I/O port for contact closure with each input being capable of
voltage sensing. Input format is software selectable with interactive power
sensing for IR ports.
Note: The I/Os are not dry closure; they are electronic switches that float at
5V when Off. Therefore, they should not be expected to work in situations
that require true dry contact (or dry closure). The I/Os do work with AMX
PC1, PC2, UPC20 and UPC20+.
IR/Serial
(Ports 9 - 16):
8 IR/Serial control ports support high-frequency carriers of up to 1.142 MHz
with each output being capable of two electrical formats: IR or Serial.
• 8 IR/Serial data signals can be generated simultaneously.
• IR ports support data mode (at limited baud rates and wiring distances).
Program Port: RS-232 DB9 connector (male) can be connected to a DB9 port on a PC.
This connector can be used with serial and NetLinx programming com-
mands, as well as other DB9 capable devices, to both upload/download
information from the NetLinx Studio program.
Configuration
DIP Switch:
Sets the communication parameters for the Program port (see Baud Rate
Settings).
ID Pushbutton: Sets the NetLinx ID (Device only) assignment for the device.
Ethernet Port: RJ-45 connector provides TCP/IP communication. This is an Auto MDI/MDI-
X enabled port, which allows you to use either straight-through or crossover
Ethernet cables.
The Ethernet Port LEDs show communication activity, connection status,
speeds, and mode information:
• SPD (speed) - Yellow LED lights On when the connection speed is 100
Mbps and turns Off when the speed is 10 Mbps.
• L/A (link/activity) - Green LED lights On when the Ethernet cables are
connected and terminated correctly, and blinks when receiving Ethernet
data packets.
AxLink Port: 4-pin 3.5 mm mini-Phoenix (male) connector that provides data and power to
external control devices. Green AXlink LED indicates the state of the AXlink
port.
Power Port: 2-pin 3.5 mm mini-Phoenix (male) connector.
Operating
Environment:
• Operating Temperature: 0° C (32° F) to 50° C (122° F)
• Operating Humidity: 20% to 85% RH
• Heat Dissipation (Typical): 36.9 BTU/hr
Included
Accessories:
• 2-pin 3.5 mm mini-Phoenix (female) PWR connector (41-5025)
• 4-pin 3.5 mm mini-Phoenix (female) AXlink connector (41-5047)
• 10-pin 3.5 mm mini-Phoenix (female) I/O connector (41-5107)
• Installation Kit (KA2105-01):
8-pin Relay Common Strip
4 rack mount screws
4 washers
• 2 8-pin 3.5 mm mini-Phoenix female Relay connectors (41-5083)
• 2 CC-NIRC NetLinx IR Emitter Cables (FG10-000-11)
• 2 removable rack ears (62-2105-07)
Other AMX
Equipment:
• 2-pin 3.5 mm mini-Phoenix male connector (41-5026)
• CC-NSER IR/Serial cables (FG10-007-10)
• ICSNet daughter card (FG2105-10)
• NCK, NetLinx Connector Kit (FG2902)
• STS, Serial To Screw Terminal (FG959)
• Upgrade Compact Flash (factory programmed with firmware):