100Mhz Bandwidth DSO4102C Hantek New 1Gsa/S Digital Oscilloscope 2Ch

 

Feature:
  • 100MHz Bandwidth; 1GSa/s Sample Rate.
  • 2 Channel Oscilloscope; 40K Record Length.
  • 7 inch 64K color LCD display, Resolution 800x480.
  • 32 kinds of Automotive measurement, with FFT function.
  • 25MHz Arbitrary waveform output (Sine wave up to 75MHz).
  • Powerful trigger function: Video, Edge, Pluse Width, Slope, Overtime, Alternate Trigger.
  • Model

    DSO4202C

    DSO4102C

    DSO4072C

     

    Oscilloscope

           

    Sample Rate

    Sampling Rate Range: 1GSa/s

     

    Equivalent Sample Rate: 25GSa/s

     

    Acquisition Modes

     

    Normal

    Normal data only

     

    Peak Detect

    High-frequency and randon glith capture

     

    Average

    Wavefom Average, selectable 4,8,16,32,64,128

     

    Inputs

           

    Inputs Coupling

    AC, DC, GND

     

    Inpits Impendance

    1MΩ±2% ‖20pF±3pF

     

    Probe Attenuation

    1X, 10X

     

    Supported Probe Attenuation Factor

    1X, 10X, 100X, 1000X

     

    Maximum Input Voltage

    CAT I and CAT II: 300VRMS (10×)

     

    CAT III: 150VRMS(1×);

     

    Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.

     

    Horizontal

           

    Sample Rate Range

    1GS/s

     

    Waveform Interpolation

    (sin x)/x

     

    Record Length

    40K

     

    SEC/DIV Range

    2ns/div to 40s/div

    4ns/div to 40s/div

     

    Sample Rate and

    ±50ppm(at over any ≥1ms time interval)

     

    Delay Time Accuracy

     

    Position Range

    2ns/div to 10ns/div;

    20ns/div to 80us/div; (-8div x s/div) to 40ms;

     

    (-4div x s/div) to 20ms;

    200us/div to 40s/div; (-8div x s/div) to 400s

     

    Delta Time Measurement Accuracy
    (Full Bandwidth)

    Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
    >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
    Sample interval = s/div ÷ 200

     
     

    Vertical

     

    Vertical Resolution

    8-bit resolution, all channel sampled simultaneously

     

    Position Range

    2mV/div to 10V/div

     

    Bandwidth

    200MHz

    100MHz

    70MHz

     

    Rise Time at BNC( typical)

    1.8ns

    3.5ns

    5ns

     

    Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled

    2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±1V

     

    500mV/div to 2V/div, ±40V; 5V/div, ±50V

     

    Math

    +, -, *, /, FFT

     

    FFT

    Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;

     

    1024 sample point

     

    Bandwidth Limit

    20MHz

     

    Low Frequency Response (-3db)

    ≤10Hz at BNC

     

    DC Gain Accuracy

    ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;

     

    ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div

     

    DC Measurement Accuracy,
    Average Acquisition Mode

    When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;
    When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div

     

    Volts Measurement Repeatability, Average Acquisition Mode

    Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions

     

    Trigger System

     

    Trigger Types

    Edge, Video, Pulse, Slope, Over time, Alternative

     

    Trigger Source

    CH1, CH2, EXT, EXT/5, AC Line

     

    Trigger Modes

    Auto, Normal, Single

         

    Coupling Type

    DC, AC, Noise Reject, HF Reject, LF Reject

     

    Trigger Sensitivity
    (Edge Trigger Type)

    DC(CH1,CH2):

     

    1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;

     

    DC(EXT):

     

    200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;

     

    DC(EXT/5):

     

    1V from DC to 100MHz;1.75V from 100MHz to 200MHz;

     

    AC: Attenuates signals below 10Hz;

     

    HF Reject: Attenuates signals above 80kHz;

     

    LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz

     

    Trigger Level Range

    CH1/CH2: ±8 divisions from center of screen;

     

    EXT: ±1.2V;

     

    EXT/5:±6V

     

    Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns

    CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;

     

    EXT: ± (6% of setting + 40mV);

     

    EXT/5: ± (6% of setting + 200mV);

     

    Set Level to 50%(typical)

    Operates with input signals ≥50Hz

     

    Video Trigger

       

    Video Trigger Type

    CH1, CH2: Peak-to-peak amplitude of 2 divisions;

     

    EXT: 400mV;

     

    EXT/5: 2V

     

    Signal Formats and Field Rates, Video Trigger Type

    Supports NTSC, PAL and SECAM broadcast systems for any field or any line

     

    Holdoff Range

    100ns ~ 10s

     

    Pulse Width Trigger

       

    Pulse Width Trigger Mode

    Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse

     

    Pulse Width Trigger Point

    Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
    Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
    Less than: The trigger point is the trailing edge.
    Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width

     
     
     
     
     
     

    Pulse Width Range

    20ns ~ 10s

     

    Slope Trigger

       

    Slope Trigger Mode

    Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope

     

    Slope Trigger Point

    Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.

     

    Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.

     

    Less than: The oscilloscope triggers when the waveform slope is less than the set slope.

     

    Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.

     

    Time Range

    20ns ~ 10s

     

    Overtime Trigger

       

    Over Time Mode

    Rising edge or Falling edge

     

    Time Range

    20ns ~ 10s

     

    Alternative Trigger

       

    Trigger on CH1

    Internal Trigger: Edge, Pulse Width, Video, Slope

     

    Trigger on CH2

    Internal Trigger: Edge, Pulse Width, Video, Slope

     

    Trigger Frequency Counter

       

    Readout Resolution

    6 digits

     

    Accuracy (typical)

    ±30ppm (including all frequency reference errors and ±1 count errors)

     

    Frequency Range

    AC coupled, from 4Hz minimum to rated bandwidth

     

    Signal Source

    Pulse Width or Edge Trigger modes: all available trigger sources

     

    The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.

     

    Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.

     

    Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.

     

    Video Trigger mode: The Frequency Counter does not work.

     

    Measure

     

    Cursor Measurement

    Voltage difference between cursors: △V

     

    Time difference between cursors: △T

     

    Reciprocal of △T in Hertz (1/ΔT)

     

    Auto Measuerment

    Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time,

     

    +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid,

     

    Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH,

     

    FRF, FFR, LRR, LRF, LFR, LFF

     

    Signal Source Mode

     

    Waveform Impedance

    DC-25MHz

     

    Sample Rate

    200MHzDDS

     

    Output Waveform

    Arbitrary wave/square wave/sine wave/triangle wave/trapezoidal wave/pulse wave/DC

     

    Frequency Resolution

    0.1%

     

    Waveform Depth

    4KSa

     

    Vertical Resolution

    12bit

     

    Frequency Stability

    <30ppm

     

    Waveform Range

    ±3.5V Max

     

    Output Impedance

    50欧姆

     

    Output Current

    50mA Ipeak=100mA

     

    System BW

    25M

     

    Harmonic Distortion

    -50dBc(1KHz),-40dBc(10KHz)

     

    General Features

     

    Display

       

    Display Type

    7 inch 64K color TFT (diagonal liquid crystal)

     

    Display Resolution

    800 horizontal by 480 vertical pixels

     

    Display Contrast

    Adjustable (16 gears) with the progress bar

     

    Probe Compensator Output

     

    Output Voltage( typical)

    About 5Vpp into ≥1MΩ load

     

    Frequency(typical)

    1kHz

     

    Power Supply

     

    Supply Voltage

    100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ

     

    120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ

     

    Power Consumption

    <30W

     

    Fuse

    2A, T rating, 250V

     

    Environmental

     

    Temperature

    Operating: 32℉ to 122℉ (0℃ to 50℃);

     

    Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)

     

    Cooling Method

    Convection

     

    Humidity

    +104℉ or below (+40℃ or below): ≤90% relative humidity;

     

    106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity

     

    Altitude

    Operating: Below 3,000m (10,000 feet);

     

    Nonoperaring: Below 15,000m(50,000 feet)

     

    Mechanical

     

    Size

    Length 385mm, Width 200mm, Height 245mm

     

    Weight

    3.5KG(with Packing); 2.08KG(without Packing)

     