CM10P7-1 Magnetically driven circulation pump 12 V
Magnetically driven, sealless, high-performance circulation pumps with brushed motors for continuous operation. Compact and powerful, ideal for circulating tasks such as: circulating water/antifreeze in heating systems for cars, boats, recreational vehicles, etc.; Circulation of fresh water for cooling vehicles; All-round pumps where self-denial is not essential.
The Johnson pump of the CM series is best suited in combination with the Webasto or Eberspächer water heaters as a quality circulation pump
Limited 2 Year Warranty
The pumps should not be used for polluted water with hard particles. CAUTION! Do not pump gasoline, solvents, thinners, highly concentrated or organic acids. When corrosive liquids need to be pumped, rinsing the pump with water after each use or after each day's work will prolong the life of the pump.
Specifications:
Pump housing and impeller: PPA, thermoplastic material;
shaft: stainless steel;
Motor: 12V DC encapsulated (according to IP67) permanent magnet, ball bearing motor, designed for continuous operation;
Liquid: water/glycol mixture; Max. 60% glycol, fresh water; liquid temp. minutes -40°C max. +100°C (Min. -40°F Max 212°F);
System pressure: 2.5 bar max (36 psi);
Voltage: 12VC;
Capacity 0.1 bar (3rd 4 ftH2O) 15 L/min (4 GPM) ;
Input power: 14W;
outlet connection Ø 16 mm (⅝") hose;
Length: 177mm - 6.97";
Width: 68mm - 2.68";
Height 85mm - 3.35";
Weight 0.53 kg - 1.2 lbsCaution: Do not pump gasoline, solvents, thinners, organic or highly concentrated acids. When pumping corrosive liquids, pump life can be extended by rinsing with water after each use or at least once a day.
Magnetically driven, sealless, high-performance circulation pumps with brushed motors for continuous operation. Compact and powerful, ideal for circulating tasks such as: circulating water/antifreeze in heating systems for cars, boats, recreational vehicles, etc.; Circulation of fresh water for cooling vehicles; All-round pumps where self-denial is not essential.
The Johnson pump of the CM series is best suited in combination with the Webasto or Eberspächer water heaters as a quality circulation pump
Limited 2 Year Warranty
The pumps should not be used for polluted water with hard particles. CAUTION! Do not pump gasoline, solvents, thinners, highly concentrated or organic acids. When corrosive liquids need to be pumped, rinsing the pump with water after each use or after each day's work will prolong the life of the pump.
Specifications:
Pump housing and impeller: PPA, thermoplastic material;
shaft: stainless steel;
Motor: 12V DC encapsulated (according to IP67) permanent magnet, ball bearing motor, designed for continuous operation;
Liquid: water/glycol mixture; Max. 60% glycol, fresh water; liquid temp. minutes -40°C max. +100°C (Min. -40°F Max 212°F);
System pressure: 2.5 bar max (36 psi);
Voltage: 12VC;
Capacity 0.1 bar (3rd 4 ftH2O) 15 L/min (4 GPM) ;
Input power: 14W;
outlet connection Ø 16 mm (⅝") hose;
Length: 177mm - 6.97";
Width: 68mm - 2.68";
Height 85mm - 3.35";
Weight 0.53 kg - 1.2 lbsCaution: Do not pump gasoline, solvents, thinners, organic or highly concentrated acids. When pumping corrosive liquids, pump life can be extended by rinsing with water after each use or at least once a day.
Technical details
manufacturer | SPX Flow Technology Sweden AB |
---|---|
ProductDimensions | 17.7x6.8x8.5 cm |
Item model number | 10-24501-03, EAN: 7330717000585 |
Included Components | 2-hole surface mounting bracket, fuse box, assembly instructions |
- This pump is an original Johnson Pump SPX FLOW Sweden product. Unlike cheap Asian counterparts, Johnson Pump's original SPX-FLOW motor offers: Proper fluid flow | Significantly longer service life | Excellent self-priming | Proper engine cooling immediately after starting
- High-performance magnet-driven, sealless circulating pumps with brush motors for continuous use. Compact and powerful, ideal for circulation tasks such as: circulating water/antifreeze in heating systems for cars, boats, recreational vehicles, etc.; circulation for cooling fresh water in vehicles; All-round pumps wherever self-priming is not absolutely necessary
- The unique design of the SPX FLOW circulating pump ensures maximum durability, especially when the end user does not regularly start the pump: - Constant pressure supply over time - Minimal fatigue damage - Good engine cooling at start-up The CM series pumps are non-self-priming centrifugal pumps and should be mounted that way that they are always flooded or primed before turning on
- The pumps should not be used for polluted water with hard particles.
- CAUTION! Do not pump gasoline, solvents, thinners, highly concentrated or organic acids. When corrosive liquids need to be pumped, rinsing the pump with water after each use or after each day's work will prolong the life of the pump
- The pump must be installed in accordance with ISO 10133 (Small craft - Electrical system - Extra low voltage direct current installation for continuous current). Other electrical devices, such as switches, circuit breakers, are installed between the pump and the positive (+) lead on the battery (on the red wire). Note that the fuse must be protected against ignition.
- All electrical connections must be placed above the highest bilge water level. All wire connections should be sealed with a marine sealant, e.g. B. Vaseline, silicone rubber or grease.
- If the pump is connected with a separate ground wire, this should be yellow/green and connected to the motor base. See the wiring diagram for correct installation. The negative cable must be black. The pumps must not run dry. A brief dry run will not damage the pump. Note that running dry for more than 30 minutes renders the pump unusable. A notice! Running noises are audible when running dry. Caution: The pump must always run in the direction of rotation
- Installation instructions The CM pumps are non-self-priming centrifugal pumps and must be filled with the liquid to be pumped before they are put into operation. The pumps must not run dry. A brief dry run will not damage the pump. Note that running dry for more than 30 minutes renders the pump unusable. A notice! Running noises are audible when running dry. Caution: The pump must always run in the direction of rotation
- The pumps are designed for continuous operation and a voltage drop of ±20°. Temperature ranges: Liquid: -40 °C to +100 °C Ambient: -40 °C to +70 °C Max. System pressure: 2.5 bar The pumps must not be used for dirty water containing coarse foreign particles.