Model |
MIN 10000TL-XH-US |
Input Data (PV) |
|
Max. Recommended PV Power(STC) |
20000W |
DC/AC Ratio |
2 |
Max. DC System Voltage |
600V |
Startup Voltage |
50V |
Full load voltage range |
210-500V |
Nominal voltage |
360V |
Operating voltage range |
50-550V |
No. of MPPT |
4 |
No. of PV strings per MPPT |
2 |
Max. input current per MPPT |
13.5A |
Max. short circuit current per
MPPT |
20A |
Input/Output Data (DC) |
|
Battery voltage range |
350V-450V |
Nominal DC voltage |
400V |
I/O DC current |
30A/30A |
I/O DC power |
10300W |
Compatible battery |
Growatt ARO battery / LG RESU10H/16H Prime battery |
Scalability |
Up to 2 for each inverter |
Output Data (AC) |
|
AC nominal Power@240V AC |
10000W |
AC nominal Power@208V AC |
8735W |
Max. AC Apparent Power |
10000VA |
Nominal AC voltage |
208V / 240V |
AC voltage range @208VAC
@240VAC |
183V-229V / 211V-264V |
AC grid frequency |
50 / 60Hz |
AC grid frequency range |
45 – 65Hz |
Max. output current |
42A |
Power factor(@nominal power) |
>0.99 |
Adjustable power factor |
0.8 leading-0.8 lagging |
THDi |
<3% |
AC grid connection type |
L1/L2/N/PE |
Output Data (Backup) |
|
AC nominal power |
10000W |
Max. AC power output |
12000VA |
Nominal AC voltage |
240V |
Max. output current |
50A |
THD |
5% |
AC Port-V2 inverter |
2 AC ports, 1 for ON grid, 1 for Backup(EPS) compatible with
ATS-US for Partial Home Backup |
AC Port-V3 inverter |
1 AC Port for ON Grid compatible with SYN200-US for Whole Home Backup |
Efficiency |
|
Max. efficiency |
98.3% |
CEC efficiency@240VAC |
97.5% |
CEC efficiency@208VAC |
97.5% |
Protection Devices |
|
DC Reverse-polarity protection |
Yes |
DC switch |
Yes |
DC surge protection |
Type II |
Insulation resistance
monitoring |
Yes |
AC surge protection |
Type II |
AC short circuits protection |
Yes |
Ground fault monitoring |
Yes |
Grid monitoring |
Yes |
Anti-islanding protection |
Yes |
Residual-current monitoring
unit |
Yes |
AFCI protection |
Yes |
General Data |
|
Dimensions (W / H / D) |
15.8/25.2/7.4 inch (400/638/187 mm) |
Weight |
45.2 lbs (20.5 kg) |
Operating temperature range |
-13oF-+140oF (-25oC-+60oC)
de-rating above 113oF |
Altitude |
9843ft (3000m) |
Internal consumption at night |
<1W (for PV inverter)/<5W (for storage inverter) |
Cooling |
Natural convection |
Electronics protection degree |
NEMA4X (IP65) |
Relative humidity |
0-95% |
Interfaces |
|
RS485 |
Yes |
WiFi/4G communication |
Optional |
Warranty: 10 years |
Yes (optional for extended 15 and 20 years warranty) |
Revenue grade meter |
ANSI C12.20 (meet 0.5% accuracy) |
IEEE1547, CA Rule21, Rule14(HECO Compliant),FCC Part15
Class B, UL1741,UL1741SA,CSA C22.2, UL1699B, UL1741 CRD |