Datasheet: https://media.digikey.com/PDF/Data%20Sheets/Power%20One%20PDFs/412-59586%20map130.pdf

Ask questions before purchase. 
All sales final, no returns.

Switching mode power supply. All outputs tested and working correctly.
+5V 20A 
+24V 3.5A 
-12V 1A
+12V 1A

Features
• Automatic 115/230 input voltage selection
• All outputs fully regulated
• Remote sense, overvoltage protection, and
overtemperature protection
• Power Fail signal included
• Greater than 100,000 Hour MTBF
• U-Channel chassis: 8.50" x 4.50" x 2.00"
(215.9mm x 114.3mm x 50.8mm)
• Includes cover
• Metric and SAE mounting inserts


Description
Power-One’s MAP130 Series of single and multiple output power supplies provide fully-regulated outputs with high
peak current capabilities in a compact 4.50" x 8.50" x 2.00" U-channel chassis. Other standard features include
autoselect AC input, EMI level B filtering, power fail, thermal shutdown (with warning), remote sense, and metric and
SAE mounting inserts.
This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50
degrees C. All products are approved to the latest international regulatory standards, and display the CE Mark.


Multiple Output Model 130W Continuous Output Power
MAP130-4001 
+5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.2V
+24V 23.0V to 25.0V 3.5A 5A 0.5% 2% 1% 23.9V to 24.1V
-12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V
+12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V


Input Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage- AC Auto-ranging. Low Range 90 115 132 VAC
High Range 175 230 264
Input Frequency AC Input. 47 63 Hz
Brown out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 90 VAC
Hold-up Time Nominal AC input voltage (115 VAC). 130W load: 40 mS
Input Current 90 VAC, 130W load. 3.3 A
RMS
Input Protection Non-user serviceable internally located AC input line fuse.
Inrush Surge Current Internally limited by thermistor. Vin = 264 VAC (one cycle). 25° C. 38 A
PK
Operating Frequency Switching frequency of main transformer (variable). Range: 16 120 kHz

Output Specifications
PARAMETER CONDITIONS/DESCRIPTION                               MIN NOM MAX UNITS
Efficiency Full Load, 115VAC. Varies with distribution of loads among outputs. 71 80 %
Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Chart
Output Power Continuous output power, all multiple output models. 130 Watts
Peak output power (60s maximum, 10% duty cycle), all multiple output models. 165
Overshoot /Undershoot Output voltage overshoot/undershoot at turn-on / turn-off 1 %
Regulation Varies by output, Total regulation includes: line changes from 90-132 VAC See Model Selection Chart
or 175-264, changes in load starting at 20% load and changing to 100% load.
Transient Response Recovery time to within 1% of initial set point due to a 50-100% load change,500 µS
4% max. deviation. (Main output only on multi-output units)
Turn-on Delay Time required for initial output voltage stabilization. 2 Sec
Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS


OVERALL SIZE: 8.50" x 4.50" x 2.00" (215.9mm x 114.3mm x 50.8mm)
WEIGHT: 2.5 lb (1.13 kg)
INPUT & OUTPUT CONNECTIONS: 6-32 SCREW WIRE CLAMPS ON 0.312" (7.9mm) CENTERS, 0.045" (1.1mm)
SQUARE PINS ON 0.156" (3.96mm) CENTERS, MATES WITH MOLEX SERIES 2139, 6442, & 41695
POWER FAIL CONNECTIONS, J2: 0.035" (0.89mm) SQUARE PINS ON 0.100" (2.54mm) CENTERS, MATES WITH MOLEX SERIES 2695 & 6471
CHASSIS: 0.090" (2.286mm) ALUMINUM ALLOY, WITH CLEAR FINISH