1、 Overview:
HM340 is a small signal generator that can generate up to 100KHz frequency, duty cycle, and phase adjustable pulse signals; Generate servo control signals; Measurement frequency;
This module is easy to use, inputting frequency data through button operations and immediately updating the output frequency.
2、 Product application:
● Signal generator;
● Instrument calibration;
● DC motor control;
● Measurement frequency;
3、 Technical parameter table:
Number Project Parameters Unit Remarks
1 pulse signal range: 1-100000 Hz                        Pulse signal
2 pulse duty cycle range: 0-100.0% duty cycle
3 pulse phase difference range 0-360 degrees Phase difference between the first and second signals
4 pulse signal amplitude 5 VDC                       Maximum amplitude 5.0Vp (output amplitude unchanged)
5. Measurement frequency range: 1-1000K HZ
6 Measurement frequency resolution 1 HZ
7. Measurement frequency voltage range ± 0.7~10 VDC                        It is directly coupled
8 servo signal frequency 100 Hz
9. Servo signal pulse width 500-2500 us
10 working voltage 7-12 VDC
11. Working current<50 mA
13 Size 57 * 45 * 20 mm                        Length X Width X Height
4、 Interface Description and Related Operations
P4 interface (power supply)
VDD: Positive pole of power supply (7-12V)
GND: Negative pole of power supply
P3 interface
FIN: Measure the frequency input terminal.
P2:   The second pulse signal output.
P1:   The first pulse signal output.
GND: Negative pole of power supply.
5、 Key Description
FUN:    (Select the operation bit for setting data) or (Long press to save the set parameter function).
UP:     Previous page.
DOWN:   Next page.
ADD:    Self adding key.
SUB:    Self subtraction key.
6、 Interface display and operation instructions:
6.1 Setting the pulse signal frequency
Interface display font:
First line "1." Frequency    “
The second line reads "* 1 1000Hz"
Key operation:
FUN: function key; (Select the operation bit for setting data) or (Long press to save the set parameter function)
ADD: Self bonding;
SUB: Self reduction key;
6.2. Setting the pulse signal duty cycle
Interface display font:
The first line "2." Duty Cycle   “
The second line reads "* 0.1 50.0%"
Key operation:
FUN: function key; (Select the operation bit for setting data) or (Long press to save the set parameter function)
ADD: Self bonding;
SUB: Self reduction key;
6.3. Set the phase difference between the first and second pulse signals (the first signal serves as a reference)
Interface display font:
First line "3." Phase      “
The second line "10C"
Key operation:
FUN: function key; (Select the operation bit for setting data) or (Long press to save the set parameter function)
ADD: Self bonding;
SUB: Self reduction key;
6.4. Output servo pulse signal
Interface display font:
The first line reads "4. Servo Control"
The second line reads "* 1 500us"
Key operation:
FUN: function key; (Select the operation bit for setting data) or (Long press to save the set parameter function)
ADD: Self bonding;
SUB: Self reduction key;
6.5 Measurement frequency
Interface display font:
The first line reads "5. Frequency 1MHZ"
The second line "OFF 0Hz"
Key operation:
(Start/Stop) Frequency measurement button: (FUN: function key)