PR10 Power Recorder is displayed by 2.4 inch TFT color
LCD, and it can measuring a variety of electrical equipment’s power, power
factor, voltage, current, frequency, accumulated electricity consumption, accumulated
electricity bill, accumulated electricity time, one shot electricity consumption,
one shot electricity bill and one shot electricity time. Daily use of
electricity and electricity bill will be recorded, you can see the form of a
chart or list of historical records. PR10 is suitable for the measuring and
monitor power consumption of the household, factory, office and other cases,
and can be used to power on or power off a various electric equipment according
your setting.
Main Features:
l The full digital operation and control.
l 2.4 - inch true color TFT LCD display.
l 0.5FS - level measuring accuracy.
l Chinese and English UI can freely to be
chosen.
l 16 currency units can be set freely.
l Four operation keys.
l Date and time can be set, 5 date formats are
supported.
l After power on, the outlet can be set to automatic
power on, no electricity, or maintain the working state of the last working.
l Power statistics have two types: cumulative
electricity and one shot electricity, one shot electricity can be cleared, it
is convenient for the measurement of electric charges in specific situations.
l There are three main display pages: the
overview page, the one shot electrical page and real-time electrical parameters
page, the default page is overview page, users can press “
l Automatic record historical data, which can
be review in the form of a list or chart, and can be stored for up to 30 years.
l Charge rates can be set up to 4 decimal places,
the number of decimal places can be adjusted freely, support 8 time sections of
sub billing function, can be easily used for peak load billing occasions.
l There are 9 timers, two are advanced timers,
which can be set to power on or power off the power supply in the specific time
on “no repeated”, “everyday”, “working day” or “weekend”, and other 7 timers
are general timers can be set to open or close the power supply on the certain
period of time in one day.
l It has alarm function and can be set to
alarm when the voltage, current, power or temperature exceeds alarm settings.
l It has output protection function and can be
set to cut off the power supply when the voltage, current, power or temperature
exceeds output protection value. The “Launch overload” mode can be set when the
current is 2A or above. No current and power are detected whether exceeds the
setting or not within 15 seconds when the “Launch overload” is checked. It also
has automatic recovery function. When “Auto Recovery” is checked, if the
machine is in output protection mode, 1 minutes later the power supply will be turned
on automatically, if the power, voltage, current or temperature exceed the
output protection value, it will restart the output protection again, and the
power supply will not powered on.
l Energy-saving setting: it can be set to turn
off the screen automatically without operation in 1 minute, 5 minutes or
10 minutes, it also can be set not to turn off the screen. The measurement
function continues after the screen is closed, press any key to turn on the
screen.
l The total power consumption and historical
records can be cleared or do the factory restore in the system setting page.
l Power resolution switch automatically
according to the measurement results, when less than 100W it display two
decimal places, when greater than 100W it display one decimal, when greater
than 1000W there’s no decimal display.
l Over range hint.
l 6 different forms of plug and socket
optional, respectively, for the new GB 10A, GB 16A, EU 16A, FR 16A, American 15A,
BS 13A.
l Small size, beautiful appearance, easy to
carry, suitable for all kinds of electrical equipment for measurement.
Function Lists
Function |
Function |
Function |
|||
Power Measuring |
● |
Time and Date
Display |
● |
2 Advanced Timers |
● |
Voltage Measuring |
● |
Five Date Format |
● |
7 General Timers |
● |
Current Measuring |
● |
History Record |
● |
Time and Date
Setting |
● |
Power Factor
Measuring |
● |
Record View by
Annual Charts |
● |
Alarm |
● |
Frequency
Measuring |
● |
Record View by
Annual Lists |
● |
Output Protect |
● |
Accumulated Electricity
Consumption |
● |
Record View by Monthly
Charts |
● |
Switch State Can Be
Setting |
● |
Accumulated Electricity
Bill |
● |
Record View by
Monthly Lists |
● |
Screen Power
Saving |
● |
Accumulated Electricity
Time |
● |
Charge Rate
Setting |
● |
History Record
Clearing |
● |
One Shot Electricity
Consumption |
● |
Segment Charging
Function |
● |
Accumulated
Electricity Clearing |
● |
One Shot Electricity
Bill |
● |
Chinese/English
Languages |
● |
Factory Reset |
● |
One Shot Electricity
Time |
● |
16 Currency Units |
● |
Help |
● |
●supported Functions
Technical index
Electrical
parameter measurement
Parameter |
Measure range |
Resolution |
Measuring accuracy |
|
Voltage |
AC85~265v[1] |
0.1v |
±(0.5FS+0.1v) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PR10-F BS 13A |
Power |
0.1~3250w[2] |
0.01w[3] |
±(0.5FS+0.01w) [3] |
Current |
0.005~13A[1] |
0.001A |
±(0.5FS+0.001A) |
|
Power factor |
0~1.000 |
0.001 |
±(0.5FS+0.001) |
|
Frequency |
45~65Hz |
0.1Hz |
±(0.5FS+0.1Hz) |
|
Electricity bill |
0~999999 |
0.01 [4] |
±(0.5FS+0.01) [4] |
|
Electricity consumption |
0~999999kwh |
0.00001kwh[5] |
±(0.5FS+0.00001kwh) [5] |
[2].Power measurement is active power;Note: [1].Voltage
and current measurements are true rms value;
[3].If
power <100w, the resolution is 0.01w, the measuring accuracy is±(0.5FS+0.01w),power>100w,
the resolution is 0.1w, the measuring accuracy is±(0.5FS+0.1w),the power> 1000w,
the resolution is 1w, the measuring accuracy ±(0.5FS+1w);
[4].If Electricity bill<10000,the resolution is 0.01, the measuring accuracy is±(0.5FS+0.01), Electricity bill >=10000, the resolution is 0.1, the measuring accuracy is±(0.5FS+0.1), Electricity bill >100000, the resolution is 1, the measuring accuracy is±(0.5FS+1);
[5]. The resolution of Electricity consumption is adjusted with the measurement results, the highest one is 0.00001kwh.
Timing index
Timing range |
999 days 23 hours
59 minutes |
Timing resolution |
1 minutes |
Currency |
RMB(Simple) |
RMB(Tradition) |
USD |
EUR |
GBP |
JPY |
Rouble |
Rupee |
Symbols |
元 |
圆 |
$ |
€ |
£ |
¥ |
руб |
Rs. |
Currency |
Won |
Lire |
Thai Baht |
Peso |
IDR |
RM |
Rand |
Common Currency |
Symbols |
원 |
₤ |
฿ |
₱ |
Rp |
RM |
R |
¤ |
Other indicators
Operating voltage |
AC85~265V |
Operating frequency |
45~65Hz |
Temperature |
0~40℃ |
Humidity |
≤90%RH |
Size (length x
width x height) |
125mmx79mmx38.5mm(the height does not contain the plug’s) |
Weight |
180g |