EPM5800-E AC/DC Electrical Parameters Tester
Instructions
1.
The main
technical parameters:
The parameters of the meter:
Work Voltage |
AC85V~265V |
Power Consumption |
<2W |
Operating Frequency |
45~65Hz |
|
Sampling Rate |
2 times /s |
Display mode |
8 0.56 inch digital LED display |
|||
Over Range Display |
"HHHH" |
Dimension |
Installation |
Screw installation |
||
Operating Temperature |
0~50℃ |
Work Environment Humidity |
≤85% RH |
|||
AC Measurement Parameters:
AC Power Measurement Range |
0~2500W |
Power Resolution |
0.01W[2] |
Power Measurement Accuracy |
0.5%FS |
AC Voltage Measurement Range |
AC85V~265V |
Voltage Resolution |
0.1V |
Voltage Measurement Accuracy |
0.5%FS |
AC Current Measurement Range |
AC0~10A |
Current Resolution |
0.001A |
Current Measurement Accuracy |
0.5%FS |
Power Factor Measurement Range |
0~1.000 |
Power Factor Resolution |
0.001 |
Power Factor Measurement Accuracy |
0.5%FS |
Frequency Measurement Range |
45.0Hz~65.0Hz |
Frequency Resolution |
0.1Hz |
Frequency Measurement Accuracy |
0.5%FS |
DC Measurement Parameters:
DC Power Measurement Range |
0~3000W |
Power Resolution |
0.01W[2] |
Power Measurement Accuracy |
0.5%FS |
DC Voltage Measurement Range |
DC0~300V |
Voltage Resolution |
0.01V |
Voltage Measurement Accuracy |
0.5%FS |
DC Current Measurement Range |
DC0~10A |
Current Resolution |
0.001A |
Current Measurement Accuracy |
0.5%FS |
AC/DC Measurement Parameters (Efficiency):
Efficiency Measurement Range |
0~100% |
Efficiency Resolution |
0.1 |
Efficiency Measurement
Accuracy |
0.5%FS |
Note:
[1] Its dimension is including the panel,without panel the depth is 29..0mm.
[2]When the
Load(AC or DC)Power <100W,The Measurement Resolution
is 0.01W,when the power>100W, the Measurement
Resolution is 0.1W,when
the power>1000W ,the Measurement Resolution is 1W.
Panel
illustrate and Wiring instructions
Wiring
instruction:
1. From
the Back of the meter, the left Terminal 1, 2 connect AC85V~265V; Left Terminal
3,4 connect the input of Drive power;
2. From
the Back of the meter, the right Terminal 1,2 connect the output of Driver,1 is positive,
2 is negative, Terminal 3,4 connect the Load, 3 is positive, 4 is negative。
Wiring must be connected as shown above
method, or it may cause damage to the tester.
Note: EPM5800-E is No shell. There is high voltage when
powered on, Banned any part of the body contact the circuit board.
Button
●Power Factor / Frequency switch
Press the left button “PF/FREQ(INC)“when steady working to switch to show Power Factor or Frequency.
Matters
needing attention
1. The tester can’t work in hot and humid
conditions,please use it in normal conditions;
2. From the Back of the meter, the left Terminal
3,4 connect the input of the Power Supply, the right Terminals 1,2 connect the
output of the Power Supply ,don’t connect the reverse side;
3. The tester’s working voltage can’t exceed
AC265V, DC voltage can’t exceed DC300V;
4. If work current greater than 10A or the load
shorted could lead to the fuse damaged, then need to replace a new 10A fuse;
5. Do not expose the tester to dusty, corrosive
gases and other harmful substances in the environment when store and using;
6. Don’t touch any part except for the panel
when the tester is working, the tester with high voltage may cause electric
shock.
Frequently
problems
1. The tester doesn’t work with power
supply, please check the Power cord connection;
2. The tester display “O”, which may be the Fuse
damaged, please replace a new Fuse;
Hole size
(unit mm):