Boiler water  controller, designed to measure the hot boiler water conductivity (sensor SR2) and open or close a motorized ball valve, that will drain water from the boiler. The automatic control of water allows the boiler to operate at safe levels of water concentration with the minimum amount of energy loses. Read article for more details.

The sensor works up to 600 psi and 486 Deg F. Orifice plate needed to assure the integrity of the sensor. Below the available kits 

Part Number 1229244  is Automated Kit for 1/2" pipes - Includes 1575e Controller, SR2 Sensor, 1/2" Union, Orifice plate


MORE INFO

Use code CCFTWZV2NJG3  for an instant 15% discount on checkout!

Lakewood Instruments boiler blowdown, conductivity controller 1575E , including controller, SR2 & PLKT plumbing. just add a motorized ball valve and you are good to go.

PLKT Plumbing kit. 1⁄2” sample/cycle and continuous sample kit
Includes unions, orifice plates, cross, tee, and manual block valve only

The Model 1575e uses the latest in microprocessor capability, giving the user a high level of application flexibility. A large illuminated graphics screen, multiple
inputs, and very easy setup characterize this new technology. The Model 1575e is ETL approved.

Watch this video to see the 1575e in operation! Click 

FEATURES

• Removable power cord and receptacles for simple conduit installations.
• Scheduled feed, which can use three relays for biocides or other chemicals.
• Two (2) water meter inputs, two (2) drum switch inputs, conductivity input, flow switch input, 4-20 mA output,
and remote conductivity input via 4-20 mA are all standard features.
• Designed with a single circuit board for better reliability and lower cost.
• Large open shallow enclosure for easy wiring.
• Ball valve delay feature allows accurate control of motorized ball valves.
• Heavy-duty stainless steel domed numeric keypad and illuminated graphical display allow for quick and easy
programming. Steel domed switches improve the tactile sensing and life expectancy of the keypad.
• LED indicators for power, alarm and relay status.

BENEFITS

Easy to program with the Lakewood plain English, intuitive, and user friendly menu interface.
• Controller can be used in boiler, cooling tower, or condensate applications when used with the appropriate
conductivity sensor.
• Single circuit board design improves reliability.
• No add-on options. 4-20 mA output and feed schedule clock features are standard.

SPECIFICATIONS

Conductivity range

500-8000 µS for Boilers

 

Conductivity sensor

2 electrode

 

Conductivity Resolution

± 10 µS (conductivity <5000 µS)

 

Temperature comp.

± 100µS (conductivity <5000 µS)

 

500NTC, NONE

 

Accuracy & repeatability

± 1.0%

 

Deadband/Setpoint

Programmable

 

Auto/Manual outputs

Menu selectable

 

Keypad

16 tactile push-buttons

 

Display

illuminated 128x64 pixel LCD

 

Drum Switch Inputs

2 digital contact inputs

 

Water meter inputs (2)

Contact head, paddle

 

Timers

wheel or turbine

 

Max. blowdown time exceeded

 

Output Signal

and relay run time exceeded

 

One 4 – 20 mA, isolated or

 

 

non-isolated optionally powered

 

 

output for conductivity

 


 

 

Input Signal

One 4-20 mA, non- isolated

 

 

internally powered input for

 

Output relays

conductivity

 

4, 3 selectable use,

 

Relay ratings

1 blowdown

 

3A each, 10A total

 

Power

120/240 VAC 50/60 Hz

 

Ambient

32° - 120°F (0 - 49°C)

 

Enclosure

NEMA 4X, ETL

 

  

Sensors/Plumbing

Boiler

Max Pressure

600 psi (41.3 bar)

Max Temp

486°F (252°C)