The module has a liquid crystal display of the current mode and parameters, supports high and low level triggering, switch control, suitable for most occasions, wide voltage power supply (6~30V), and supports UART data upload and parameter setting, there is a key to pause function (STOP key ), with reverse connection protection, reverse connection does not burn, the module adds a sleep mode, after enabling, no operation for about 5 minutes, automatically turn off the group LCD backlight, any key to wake up; the module can set different OP, CL, LOP parameters, These parameters are saved independently of each other, and all set parameters are automatically saved after power-off.

Product Parameters:
Working voltage: 6-30VDC
Trigger signal source: high level trigger (3.0V~24V), low level trigger (
0.0V~0.2V), switch control (passive switch).
Output capability: can control devices within 30V 10A DC or 220v5A AC
Quiescent current: 15mA
Working temperature: -40—85°C
With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit boards, set parameters will always remember after power off.
Size: 7.1*3.9*2.5cm
Working Mode Introduction(P1~P7):
P0: After the signal is triggered, the relay conduction in OP time then disconnects; In the OP time, the signal is invalid.
P1: After the signal is triggered, the relay conduction in OP time then disconnects; In the OP time, the signal triggers a new timer.
P2: After the signal is triggered, the relay conduction in OP time then disconnects; In the OP time, signal trigger reset timer, relay disconnected and stop timing.
P3: After the signal is triggered, the relay disconnects the CL time, and then the relay conduction.
P4: After the signal is triggered, the relay conduction the OP time, and then the relay disconnects the CL time, and then loops the above action, gives the signal again in the loop, relays disconnect, stops the timer; and the number of cycles (LOP) can be set; End of cycle, keep relay disconnected;
P5: After the signal is triggered, the relay disconnects the CL time , and then the relay conduction the OP time, and then loops the above action, gives the signal again in the loop, relays conduction, stops the timer; and the number of cycles (LOP) can be set; End of cycle, keep relay conduction;
P6: No trigger signal after power-on, After the relay conduction OP time, the relay disconnects the CL time, and then loops the above action, signal is invalid in the loop, the number of cycles (LOP) can be set; End of cycle, keep relay disconnected;
P7: No trigger signal after power-on, After the relay disconnects the CL time, the relay conduction OP time, and then loops the above action, signal is invalid in the loop, the number of cycles (LOP) can be set; End of cycle, keep relay conduction;
P8: Signal hold function: The signal is maintained, the timing is cleared, and the relay conduction; when the signal disappears, the relay disconnects after the timing OP; during the timing, there is another signal and the timing is cleared;
P9: Signal hold function: The signal is maintained, the timing is cleared, and the relay disconnected; when the signal disappears, the relay conduction after the timing CL; during the timing, there is another signal and the timing is cleared;
(P0~P7) mode, short press the pause button, Start timing if the system is not timed; If the system is already timed, the system pauses the timer, the relay disconnected, flashing "out" to indicate a reminder;
P8/P9 mode, The pause button as a trigger signal in the Run interface, Short / Long press fail;


DataCaciques