HLK-LD101
1. Summary
HLK-LD101 is an X-band radar module working at 10.525GHz. Based on the Doppler effect, this design uses fixed-frequency, directional transmitting and receiving antennas, which are first combined with chip integration technology and microwave antennas on the market.
It has the characteristics of anti-interference, small size, no wall penetration, high stability, good consistency, and good clutter and high-order harmonic suppression effect.
The on-board integrated IF demodulation, signal amplification, digital processing, light intensity detection, timing and other functions are integrated on the module, and the serial port function is opened at the same time, which is convenient for users to adjust relevant parameters.
This product adopts pulse power supply mode, and the average power consumption can be reduced to 7mA.
2. Product Features
Working frequency 10.525GHz
Wide voltage operation:+3.3V~15V
Module size:20mm*25mm*4mm
The sensing distance is about 7m (straight line distance)
Detect angle 100°
Maximum transmit power:2dBm
Maximum receiving sensitivity:-95dBm
Motion detection
Onboard integrated transmit and receive antennas
3. Product Application
Smart home
Smart lighting
Smarthome appliances
Smart security
Typical Application(LED sensing light)
4. Product Parameters
TA=25℃
Symbol |
Parameters |
Test Conditions |
Min |
Typ |
Max |
Unit |
Input power |
||||||
VCC |
Working voltage |
|
3.3 |
|
15 |
V |
I |
Working current |
VCC=5V |
8 |
12 |
35 |
mA |
Output |
||||||
fOSC |
Microwave frequency |
VCC=3.3~12V |
|
10.525 |
|
GHz |
P |
Transmit power |
VCC=3.3~12V |
|
|
2 |
dBm |
Vout |
Output voltage |
|
2.9 |
3 |
3.1 |
V |
Iout |
Output current |
|
|
|
10 |
mA |
Tw |
Power-on stabilization time |
|
10 |
15 |
25 |
S |
Temperature and humidity range |
||||||
TA |
Working temperature |
|
-20 |
|
+60 |
℃ |
TB |
Storage temperature |
|
-40 |
|
+85 |
℃ |
HA |
Working humidity |
|
10 |
|
95 |
% |
HB |
Storage humidity |
|
0 |
|
95 |
% |
Detection range |
||||||
|
Radial detection distance① |
|
1 |
1.2 |
1.5 |
m |
Ts |
Turn-off delay ② |
|
|
5 |
|
S |
ESD features |
||||||
|
Contact discharge |
|
|
2 |
|
kV |
|
Air discharge |
|
|
2 |
|
kV |
Table1:electrical parameters
Notes:
① The sensing distance can be set according to customer needs;
② The turn-off delay can be set according to customer needs;
5. Pin configuration and function description