YMGI 36000 BTU 4 Zone Ductless Mini Split AC Heat Pump 9k+9k+9k+9k

YMGI 36000 BTU 4 Zone Ductless Mini Split AC Heat Pump 9k+9k+9k+9k

YMGI 36000 BTU QUAD ZONE DUCTLESS SPLIT AIR CONDITIONER WITH HEAT PUMP 4 x 9000

Item Description

YMGI 36000 BTU 

Four ZONE

9000 BTU + 9000 BTU + 9000 BTU+ 9000 BTU

DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP 

208-230V 21 SEER DC INVERTER

 

THE CONFIGURATION OF THIS SYSTEM IS DESIGNED 

TO SUIT IN BOTH RESIDENTIAL AND COMMERCIAL eNVIRONMENT. 

SUCH AS RESTURANT, café, SHOPS AND WORKSHOPS WITH HIGH TRAFFIC

 
IF YOU REQUIRE DIFFERENT INDOOR MATCH PLEASE CONTACT US
 
 
 
 
 
 

 ModelWMMS-42CH-V2B(59)4/09EW-09EW-09EW-09EW

 Condition: Brand New item unused unopened in original sealed package

 

Function

 

  •            Cooling
  •            Heating
  •            Dehumidification
  •            Air Purification

 

 

Description

 

  •          Four Zone Air Conditioner system with Heat Pump
  •          One Outdoor unit with 4 Indoor units (4 X 9000 BTU)
  •          36000 BTU Heating Cooling And Dehumidification
  •          21 SEER DC Inverter Compressor
  •          Super Quiet Auto Restart, digital Timer and Turbo Mode

 

 

 Feature 

  •           Variable Speed Compressor
  •           21 SEER efficiency, DC inverter technology
  •           AHRI certified
  •           Whisper-quiet operation, Low voltage start 
  •           Stable Operation at Low Frequency
  •           Random pitch cross flow fan wheel
  •           Dry anti-mould coil
  •           LCD display, Turbo mode, 3 fan speeds 
  •          Quick access, washable air filter
  •          Auto level swing, Wide angle air distribution, Auto Restart,
  •          24-hour programmable timer, Sleep mode, Independent  Dehumidification 
  •          Enhanced copper/coil, Corrosion resistant cabinet, Thoroughly tested ensure longer performance

 

 

 

 

YMGI Smart Technologies

 

 

  •  Auto-Restart: After a power cut the unit will restart automatically with the previous function setting when the power returns.
  •  Intelligent Auto-Defrosting: The unit can enter or quit the defrosting mode automatically by timely detecting the frosting situation of the outdoor unit.
  •  Sleep Mode: Because our body temperature cools down as we sleep, the unit automatically adjusts the setting for all-night comfort.
  •  Air Purifying and Deodorizing Filters: Industrial development has offered from one side a better life style, but on the other side, it has increased polluting substances presence in the air that helps in spreading of various kinds of diseases. Among the polluting agents, the ones we can more frequently find at home are anti-bacterial dust particles, moulds and etc, which are causing allergic phenomenon, breathing and typical upper respiratory problems. This dual washable filter screen is effective in preventing anti-bacteria mould and duct particles and ensuring a healthy indoor environment.
  • Turbo Mode: This function enables the unit to reach the preset temperature in the shortest time.
  • Self-diagnosis and Auto-Protection Function: This function can electronically detect the errors and display the diagnosis by a series of flashing LEDs on the indoor unit. Then the unit will automatically switch to protection mode.

 

 

IMPORTANT NOTES ABOUT THE DC INVERTER SYSTEM VARIOUS PERFORMANCES:

 

  •  The rated performance data printed on the nameplate were tested per AHRI 210/240 standards at standard indoor & outdoor conditions and standard installation set-up.
  •  Actually the DC inverter outdoor unit could modulate to match whatever capacity needs are called/requested from indoor side, to produce a wide range of capacities, minimum could be about 15% of the rated number and maximum could be around 160% of the rated number.
  • Once the DC inverter system is installed, each indoor unit's output and so the outdoor unit performance will all vary over the operation period: soft starting, turbo quick cooling/heating, maintaining, defrosting, switching, and other condition changes.
  •  Actual performance varies upon many factors such as indoor and outdoor temperatures, inter-connecting pipe length/ bending, elevation difference between indoor and outdoor units, refrigerant charging level, vacuum level, leakage, air or moisture or contamination level, foreign substance left in the piping, indoor filter clean level, indoor and outdoor coil conditions, and other factors.
  • When the rated total capacity of all the indoor units exceeds the rated capacity of outdoor unit, each indoor unit may not output the rated capacity and one may differ from other, upon other installation/operation factors, it all units are turned on to run compressor simultaneously.
 

PIPE ADAPTER 

  •  Whenever the outdoor unit gas valve of size 3/8" is to connect with indoor unit gas pipe of 1/2" or 5/8", one 3/8" - 1/2" or 3/8" - 5/8" adapter is to be used in between. This reducer is packed separately and shall be installed at job site.
  •  Any indoor unit is 30' or more apart from the outdoor unit, better to adjust refrigerant. If it is 50' or more apart, better to upper size the copper lines and adjust refrigerant.
  •  Any run cannot be more than 100' apart from the outdoor unit; otherwise, that indoor unit capacity may be reduced

 

 

 

BTU / Area Coverage Guide

9000 BTU covers Approx 300-350 ft²

12000 BTU covers Approx 400-450 ft²

18000 BTU covers Approx 700-750ft²

24000 BTU covers Approx 1000-1100 ft²

* Cover area is a guide only, other factors should also take into consideration such as ceiling height, number of windows and wall material those affect insulation. 

 

 

Application

 

  •          Bar and Pub
  •          Hotel
  •          Home
  •          Office
  •          Green House
  •         Condos
  •          Resort
  •          Factory
  •          Nursing Home
  •         Residential Apartment
  •         Office
  •         Restaurant

 

 

 

 Package Include

 

  •  Condenser R410A pre-charged (outdoor unit) 
  •  4 X Air Handler w/wall bracket (for indoor unit)
  •   4 X Wireless Remote controls 
  •   4 X Installation kit ( insulated copper line set with nuts, control cable and misc.)
  •  Installation and Operation Manuals
  •  Manufacturer warranty Certificate

 

 

 

 

Warranty

All YMGI products come with standard 5 years limited warranty for compressor and 2 years limited warranty of parts for indoor units and installation kit. If you have any questions related to the operation of your equipment you are always welcome to contact us by email or phone and we will there to assist. Our contact information will be available in the warranty certificate.

 

 

Notice and Installation

YMGI does not provide installation for equipment. Customer will need to hire a licensed HVAC technician and install the equipment in a professional manner.

Installation by unlicensed personnel will automatically void YMGI standard warranty and it is strongly not recommended as it may cause danger to your property. YMGI and bizlander cannot be held liable for any damage that caused by improper installation. Please be advised that federal law prohibits opening any refrigeration line by anyone not properly licensed.

Please be noted returned warranty certificate will be deemed as valid only if it is signed, dated and noted with details of technician which responsible for the installation.

    

Disclaimer

YMGI endeavour to ensure all information given here (include technical data, and other information) is correct. However due to omissions, errors and out-of-date data from constant improvement, YMGI and bizlander reserve all rights to modify any part of the content without notice. Every reasonable effort has been made to ensure all information contained here is correct. 

Listed by Frooition

We will be gladly assis you with any support on Technical specifications, Pleaese Click here for our contact dertails

We accept Paymenet via Ebay, Paypal, Credit  Card or Bank Transfer

All YMGI system will come with Manufacture Warranty at 7 Years on Compressor and 2 Years on Parts

inkFrog