4OXV CiTiceL Oxygen Gas Sensor (O2 Sensor) Key
Features and Benefits:
• False alarm immunity
• Enhanced response time in extreme applications
• Reliably meets stated life
• Superior environmental performance
4OXV CiTiceL Oxygen Gas Sensor (O2 Sensor) Technical Specifications
MEASUREMENT
Technology:Electrochemical
Measurement Range:1-25% vol. O2
Maximum Overload:30% vol. O2
Output Signal: 0.10 ± 0.02 mA in Air
Response Time (T90):<15 Seconds
Zero Current (Offset):<0.6% vol. O2
Linearity:Can be considered linear in many cases.
See Operating Principles (OP-02) for further details.
ELECTRICAL
Recommended Load Resistor:100 Ω
MECHANICAL
Casing Material:ABS
Weight:<16 g
Orientation Sensitivity:<0.2% vol. O2 equivalent
ENVIRONMENTAL
Operating Temperature Range:-20°C to +50°C (up to 3 months continuous across RH range)
Recommended Storage Temp:0°C to 20°C
Thermal Transient(Temp. plunge +22°C to -20°C):<23.5% vol. O2
Operating Pressure Range:Atmospheric ± 20%
Pressure Coefficient:<0.02% signal/mbar
Pressure Transient (60 cm H2O step change) : <200% signal change
Relative Humidity Range:(at 0°C to 20°C)
Continuous:5 to 95%RH non-condensing
Short Term:0 to 99%RH non-condensing