Untitled Document

Normally Closed – opens when power is applied 

12 Volt DC Solenoid Valve
Function Normally Closed
Connection 1/4” Inch FNPT
Temperature Range 15 – 250F
Pressure Range 0 – 115 PSI
Power Requirements 8 Watts
*Suitable Media
Water – Air - Fuel














Specifications
Body Material 316 Stainless Steel
Components 304 Stainless Steel
Seal Material Viton® Diaphragm
Operation Type Direct Acting Valve
Coil Connection Lead Wires
Orifice Size 3 mm 
Cv Value .4
*Duty Cycle 100% but not indefinitely
Weight 10 oz
Height 2.62"
Length 1.60" port to port
Width 1.20" 

Connection – No Polarity, + and – can be interchanged.

The valve timing is uncertain, however it is very fast acting. Less than one second.

*The Orifice size is 3mm and Cv value is 0.4. This valve is not recommended for gravity fed systems because of the small orifice size

Mounting position is preferably coil up but can be mounted in any position.

*Consult a chemical compatibility expert for correct seal and valve body material choice.

*Duty Cycle – Like most solenoid valves the coil will become hot to the touch when left on continuously. The temperature will stabilize without failure. Leaving the valve powered on for long periods of time will reduce the life of the coil. Whenever possible the valve should be installed in a well ventilated are to increase the life of the coil. The valve is not intended to be left energized as a fail-safe for power outages. In this case please contact us for other options.

A pre-filter is always recommended to keep the diaphragm free from debris and the valve functioning properly.

inkFrog