Normally Closed – opens when power is applied
Function | Normally Closed |
Connection | 1/4” Inch FNPT |
Temperature Range | 15 – 250F |
Pressure Range | 0 – 115 PSI |
Power Requirements | 8 Watts |
*Suitable Media |
Water – Air - Fuel |
Body Material | 316 Stainless Steel |
Components | 304 Stainless Steel |
Seal Material | Viton® Diaphragm |
Operation Type | Direct Acting Valve |
Coil Connection | Lead Wires |
Orifice Size | 3 mm |
Cv Value | .4 |
*Duty Cycle | 100% but not indefinitely |
Weight | 10 oz |
Height | 2.62" |
Length | 1.60" port to port |
Width | 1.20" |
Connection – No
Polarity, + and – can be interchanged.
The valve timing is
uncertain, however it is very fast acting. Less than one second.
*The Orifice size is 3mm and Cv value is 0.4. This valve is not recommended for gravity fed systems because of the small orifice size
Mounting position is
preferably coil up but can be mounted in any position.
*Consult a chemical
compatibility expert for correct seal and valve body material choice.
*Duty Cycle – Like
most solenoid valves the coil will become hot to the touch when left on
continuously. The temperature will stabilize without failure. Leaving the valve
powered on for long periods of time will reduce the life of the coil. Whenever
possible the valve should be installed in a well ventilated are to increase the
life of the coil. The valve is not intended to be left energized as a fail-safe
for power outages. In this case please contact us for other options.
A pre-filter is
always recommended to keep the diaphragm free from debris and the valve
functioning properly.