Normally Closed – Opens when power is applied
Gravity Feed Capable – No Minimum Pressure
Function | Normally Closed |
Connection | 1-1/2” Inch FNPT |
Temperature Range | 15 – 250°F |
Pressure Range | 0 – 90 PSI |
Power Requirements | 40 Watts |
*Suitable Media |
Water – Air - Fuel |
Body Material | 304 Stainless |
Components | Stainless Steel |
Seal Material | Viton® Diaphragm |
Operation Type | Semi-Direct Lift Valve |
Coil Connection | 5.5" Lead Wire |
Orifice Size | 40 mm |
Cv Value | 29 |
*Duty Cycle | 100% but not indefinitely |
Weight | 4 lbs 14 oz |
Height | 6.00" |
Length | 4.33" port to port |
Width | 3.35" |
Connection – No
Polarity, + and – can be interchanged.
The valve timing is
uncertain, however it is fast acting. Less than one second.
Mounting position is preferably coil up but can be mounted in any position.
*Consult a chemical
compatibility expert for correct seal and valve body material choice.
*Duty Cycle – Like
most solenoid valves the coil will become hot to the touch when left on
continuously. The temperature will stabilize without failure. Leaving the valve
powered on for long periods of time will reduce the life of the coil. Whenever
possible the valve should be installed in a well ventilated are to increase the
life of the coil. The valve is not intended to be left energized as a fail-safe
for power outages. In this case please contact us for other options.
A pre-filter is
always recommended to keep the diaphragm free from debris and the valve
functioning properly.