Overview

DP6000series high voltage differential probes are designed for the measurement of high voltage differential signal,

to meet the demand for floating measurement. The bandwidth can be as high as 100MHz, meeting the demand for 

majority of measurement systems. There are a variety of ranges to choose from, and their differential voltage

measurement range can meet with the demand for majority of tested circuits; users may go into test mode to adjust

the offset voltage, and meanwhile to adjust automatically to prevent probes being disordered after years’ of use;

the electronic touch buttons give them longer working life; with function of 5MHz bandwidth limit selection, whose

frequency bandwidth fits for the FETs switching frequency measurement in most switching power supplies, and 

they can filter out higher frequency noise and interference; with sound & light alarming function, which can also be     closed manually, is more humanized designed; with USB power supply connector,  easier and more flexible for       use; the probes are equipped with standard BNC input connectors, can be used with any manufacturer              oscilloscope ( oscilloscope input impedance should set to 1MΩ; when 50Ω is selected, the attenuation multiply       attenuates double.)  to test waveform of the tested circuits; automatic save function, to prevent users 

re-operating in case of power supply drops. The probes have good capability of common mode noise suppression,

can be widely used in the research and development, debugging or overhauling work for switching power 

supply, frequency converter, electronic ballast, frequency conversion electronic appliances and other electric

power equipments.

Application

■ Floating voltage measurement

■ Frequency converter

■ Switching power supplies designs

■ Welding, plating power supplies

■ Induction heating, electromagnetic oven

■ Motor driven design

■ Electronic ballast design

■ CRT displayer design

■ Inverter, UPS power supplies

■ Frequency conversion electrical appliances

■ Power conversion and related design

■ Electrical engineering experiment

■ Low voltage appliances experiment

■ Power electronics and electric drive experiments

Modal

DP6700

Bandwidth(-3dB)

DC to 70MHz

Rise Time

≤5ns

Accuracy

±2%

Range Selection(Attenuation Rate)

100X/1000X

Maximum Differential Test Voltage(DC + Peak AC)

100X

700V

1000X

7000V

Maximum input commonm ode voltage ( voltage-to-earth Vrms)

1000V CATIII
2300V CATI

Input Impedance

Single-end ed to ground

20MΩ

Two inputs

40Ω

Input Capacitance

Single-end ed to ground

<5pF

Two inputs

<2.5pF

CMRR

DC

>80dB

100KHz

>60dB

1MHz

>50dB

Noise(Vrms)

100X

<200mV

1000X

<1.2V

propagation delay (standard 1 m output lead)

18ns±1ns

Bandwidth limit(5MHz)

≥-3dB@5MHz

Differential overvoltage detection level

100X

700V

1000X

7000V

Overload indicator (red light)

YES

Overload Alarm 

Yes(Can shut up manually)

Offset Setting function

Yes( Set in test mode)

Terminate Load

1MΩ

Power Supply

USB 5V/1A adapter