range of productTwido
product or component typeCompact base controller
discrete I/O number10
discrete input number6
discrete input voltage24 V
discrete input voltage typeDC
discrete output number4 for relay
[Us] rated supply voltage100...240 V AC
use of slotMemory cartridge or realtime clock cartridge
data backed upInternal RAM lithium, 30 days autonomy, charging time: 10 h, battery life: 10 year(s)
integrated connection typePower supply
Non isolated serial link mini DIN, Modbus/character mode master/slave RTU/ASCII (RS485) half duplex, 38.4 kbit/s
Complementary
discrete input logicSink or source
input voltage limits20.4...28.8 V
discrete input current11 mA for I0.0 to I0.1
7 mA for I0.2 to I0.5
input impedance2100 Ohm for I0.0 to I0.1
3400 Ohm for I0.2 to I0.5
filter time35 µs + programmed filter time for I0.0 to I0.5 at state 1
45 µs + programmed filter time for I0.0 to I0.5 at state 0
insulation between channel and internal logic1500 Vrms for 1 minute
insulation resistance between channelNone
minimum load0.1 mA
contact resistance30000 µOhm
load current2 A at 240 V AC inductive load, operating rate <30 cyc/mn for relay output
2 A at 240 V AC resistive load, operating rate <30 cyc/mn for relay output
2 A at 30 V DC inductive load, operating rate <30 cyc/mn for relay output
2 A at 30 V DC resistive load, operating rate <30 cyc/mn for relay output
mechanical durability20000000 cycles for relay output
electrical durability100000 cycles for relay output
current consumption24 mA at 5 V DC at state 1
26 mA at 24 V DC at state 1
5 mA at 5 V DC at state 0
I/O connectionNon-removable screw terminal block
network frequency50/60 Hz
supply voltage limits85…264 V
network frequency limits47…63 Hz
power supply output current0.25 A for 24 V DC sensors
input current250 mA
inrush current35 A
protection typePower protection by internal fuse
power consumption in VA20 VA at 100 V
30 VA at 264 V
insulation resistance> 10 MOhm at 500 V, between I/O and earth terminals
> 10 MOhm at 500 V, between supply and earth terminals
program memory700 instructions
exact time for 1 Kinstruction1 ms
system overhead0.5 ms
memory descriptionInternal RAM, 128 counters, no floating, no trigonometrical
Internal RAM, 128 internal bits, no floating, no trigonometrical
Internal RAM, 3000 internal words, no floating, no trigonometrical
Internal RAM, 64 timers, no floating, no trigonometrical
free slots1
realtime clockWithout clock
counting input number1 counting input(s) at 20000 Hz 32 bits
3 counting input(s) at 5000 Hz 16 bits
analogue adjustment points1 point adjustable from 0...1023
status LED1 LED (green)PWR
1 LED (green)RUN
1 LED per channel (green)I/O status
1 LED (red)module error (ERR)
1 LEDuser pilot light (STAT)
depth70 mm
height80 mm
width90 mm
terminals description PLC n°1ALT
COM_NEG#0-5
(2)IN_DIS#2
(+)PW_OUT_POS
(-)PW_OUT_NEG
(5)IN_DIS#5
(3)IN_DIS#3
(0)IN_DIS#0
(4)IN_DIS#4
TB_TOP
(1)IN_DIS#1
terminals description PLC n°2COM_POS#0-5
(0)IN_DIS#0
(-)PW_OUT_NEG
(3)IN_DIS#3
(1)IN_DIS#1
(4)IN_DIS#4
ALT_1
TB_TOP
(5)IN_DIS#5
(+)PW_OUT_POS
(2)IN_DIS#2
terminals description PLC n°3(GND)GROUND
(0)OUT_DIS#0
(2)OUT_DIS#2
(3)OUT_DIS#3
(L)PW
TB_BOTTOM
(N)PW
(1)OUT_DIS#1
(COM1)COM#3
(COM0)COM#0-2
net weight0.23 kg