Selling the pictured Keyence AP-30K Two-Color Digital Display Pressure Sensors. This listing includes the 2 Pressure Sensors -- the Main Unit NPN and Main Unit PNP -- and User Manual. 

This is what the manufacturer says about this model: 


AP-30 series digital air pressure sensor with unique 2-color digital display replaces conventional mechanical gauges.


Features

Basic Specs for Main Unit NPN and Main Unit PNP:

Type

Negative pressure, NPN

Negative pressure, PNP

Rated pressure

0 to -29.9 inchHg

Fluid type

Air or non-corrosive gases

Type of pressure

Gauge pressure

Display

3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43")

Display resolution

0.1 inchHg, 0.1 kPa, 1 mmHg, 0.001 bar

Detectable pressure range

-15 to +110 % of F.S.

Display temperature characteristic

±1 % max. (of F.S.) of detecting pressure at 25 °C 77 °F (0 to 50 °C 32 to 122 °F)

Response time (Chattering prevention function)

2.5/5/100/500 ms (selectable)

I/O

1 to 5 V (Load impedance: 47 kΩ min.)

NPN open collector 100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable)


PNP open collector 100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable)

Rating

12 to 24 VDC ±10 %

50 mA (at 24 V) or less, 90 mA (at 12 V) or less

Environmental resistance

72.5 PSI

0 to +50 °C 32 to 122 °F (No freezing)

35 to 85 % RH (No condensation)

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions