WADEO Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit ( Low Pressure Propane Valve with 3/8" Flare Inlet & Outlet ), Suitable for Gas Grill, Heater, Fire Pit
Product

Product

  • Material: The fire pit gas control valve kit are made of high quality brass material with heavy-duty construction for durable use.
  • Package Included: Valve, Thermocouple, Plastic Black Bakelite Knob
  • Size: Thermocouple Length: 600mm/23.62inch; Head Tip: M8; Knob Diameter 44mm; "D" Insert for Valve: 6.0-6.1mm
  • Application: Suitable for Low Pressure Repair Control System for Grill, Fire Pit, Fireplace & Heater
  • CE&CSA tested Main Control Valve In & Out with 3/8" Male Flare thread (Max BTU rating: 50000, Working Pressure 65 mbar)
Product Details are Below, Don't Miss them!
Shipping

Free & Fast Shipping,

Free Returns

All products in our store are shipped from the US warehouse and you don't need to pay any shipping fees!

If you need to return the item you purchased, we will provide you with a shipping label.

Contact

Contact

We can be contacted at any time through eBay messages if you have any questions, comments or product requests. We will respond to you within 24 hours and do our best to help you out! We encourage our customers to contact us with any questions or concerns! We'd like to be sure you are completely satisfied with your purchase.

Features and further details

Operation Instructions


1). Fix the valve on a plate or board of your grill or fire pit by the head screw and flange.


2). Connect your inlet and outlet hose on inlet and outlet side. (faston it tightly enough in case of gas leakage)


3). Faston the thermocouple nut M*8 on the valve end tightly


4). Connect thermocouple and end thread well


5). Open gas by correct size knob and push your valve around 5-10s till the thermocouple head is heated enough.


6). Release your hand and it work properly If when you release hand, gas valve shut off again, Please check
a. If your thermocouple is always be heated on flame
b. If the thermocouple end is well connect with valve
c. If the inlet and outlet side well connect with hose you have

Possible problems occurs during your use:
1) Valve after turn can not stick during using


Reason:
a. The thermocouple head is not heated in right place, please adjust thermocouple tip position.


b. The connection between thermocouple end and valve is not connected tight enough or too tight, please adjust the screw again.


c. Need to push valve first then turn the spindle and hold for few seconds, it cannot stick immediately may need 5-15 Seconds.