Hioki 3285 Clamp Meters -AC/DC 2000A ,AC/DC 600 Volt ,Excellent Condition Japan


It is like new


Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The 3285 clamp multimeter measure DC, AC or AC+DC current in live power lines without tapping into or connecting the lines, and includes a variety of features and functions including automatic zero adjustment that turns a normally troublesome task into a one-touch operation. Model 3285 comes with AC adapter and output terminals to enable connection to other instruments such as recorders.


Using the external output functions of the 3285 in combination with a HIOKI Memory HiCorder enables recording of current and frequency fluctuations and recording and harmonic analysis of instantaneous waveforms. The monitor output (MON) spans a wide frequency range from DC to 20 kHz (15 kHz in the case of 3285), which allows the units to be used for electric current analysis in various fields ranging from batteries to inverters.


The AC+DC mode enables measurement of the RMS value of full- or half-wave rectified waveforms used in electrical machinery.




Manufacturer Specs

AC Current range

AC (RMS or Peak value)200.0 or 2000 A AC, 2 ranges (±1.3 % rdg. ±3 dgt. at 50 or 60Hz), AC+DC (RMS or Peak value)200.0 or 2000 A AC, 2 ranges (±1.3 % rdg. ±13 dgt. at 50 or 60Hz), Effective value rectifier


DC Current range

DC (Average or Peak value)200.0 or 2000 A DC, 2 ranges (±1.3 % rdg. ±3 dgt.)


AC Voltage range

AC (RMS or Peak value)30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±3 dgt. at 50 or 60Hz), AC+DC (RMS or Peak value)30.00 to 600 V AC, 3 ranges (±1.0 % rdg. ±7 dgt. at 50 or 60Hz), Effective value rectifier


DC Voltage range

DC (Average or Peak value)30.00 to 600 VDC, 3 ranges (±1.0 % rdg. ±3 dgt.)

Frequency Measurement: 10 to 1000 Hz, 2 ranges (±0.3 % rdg. ±1 dgt.)


Analog Output DC, or AC 1 V /f.s. ,Level output: with REC mode, Waveform output: with MON mode

Frequency characteristics (at AC current / voltage) DC, 10 to 1 kHz

Display Section Current / 2500 dgt. Voltage / 3750 dgt. Bar graph / 35 seg

Sampling Rate 2 or 4 times/sec (Slow: 1 times/3 sec)

Crest Factor (RMS) 2.5 (1.7 at 600 A range), 1.42 (2000 A range)

Max. Circuit Voltage 600 V AC rms (insulated wire)


Power Supply

6F22(006P) × 1 (Continuous use 25 hours), or AC adapter

Core jaw dia. Ø55 mm(2.17 in)

Dimensions 62 mm(2.44 in)W × 260 mm(10.24 in)H × 39 mm(1.54 in)D

Weight 540 g (19.0 oz)

Accessories 9207-10 TEST LEAD (1), 9345 CARRYING CASE (1), Hand strap (1)