Product characteristics
>th >Dimensions [mm]

Electrical designPNP/NPN
Output functionnormally open
Sensing range [mm]8
Housing
M18 x 1 / L = 70

Application

Systemgold-plated contacts; Increased sensing range
ApplicationUse in mobile and harsh applications

Electrical data

Operating voltage [V]10...36 DC
Current consumption [mA]< 10; (only in 3-wire operation)
Protection classII
Reverse polarity protectionyes

Outputs

Electrical designPNP/NPN
Output functionnormally open
Max. voltage drop switching output DC [V]2.5
Minimum load current [mA]2; (only in 2-wire operation)
Max. leakage current [mA]0.5; (only in 2-wire operation)
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]200
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes

Monitoring range

Sensing range [mm]8
Operating distance [mm]0...6.48
Increased sensing rangeyes

Accuracy / deviations

Correction factorsteel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.45 / copper: 0.35
Hysteresis [% of Sr]1...20

Operating conditions

Ambient temperature [°C]-40...85
ProtectionIP 67; IP 69K

Tests / approvals

EMC
Automotive area
Noise emission and noise interference: ECE R10E1 type approval
noise immunity according to DIN ISO 11452-2100 V/m
conducted interference in 24 V networks to ISO 7637-2: 2004 (pulse 1 to 4) and ISO16750-2: 2012 (load dump)
pulse1 2a 2b 3a 3b 4 Load dump
Severity levelIII III III III III III Test A
Failure criterionC A C A A C C
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated10 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-5 Surge0,5 kV mains line to line
EN 61000-4-6 HF conducted10 V
EN 55011class B
Vibration resistance
EN 60068-2-6 Fc20 g (10...3000 Hz) / -20...50 °C
50 sweep cycles per frequency; 1 octave per minute in 3 axes
Shock resistance
EN 60068-2-27 Ea100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C
Continuous shock resistance
EN 60068-2-2740 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C
Fast temperature changes
EN 60068-2-14 NaTA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles
Salt spray test
EN 60068-2-52 Kbseverity level 5 (4 test cycles)
MTTF [years]1192
UL approval
Ta0...40 °C
Enclosure typeType 1
voltage supplyHazardous voltage
File number ULE174191

Mechanical data
>th >Mounting

Weight [g]62
Housing
flush mountable
Dimensions [mm]M18 x 1 / L = 70
Thread designationM18 x 1
Materialhousing: stainless steel; sensing face: LCP natural; LED window: PEI; lock nuts: brass

Displays / operating elements

Display
Switching status4 x 90° LED, yellow

Accessories

Items supplied
lock nuts: 2

Remarks

Pack quantity1 pcs.

Electrical connection - plug

Connector: 1 x M12; coding: A; Contacts: gold-plated