- E1 type approval (German Federal Motor Transport Authority)
- Wide operating temperature range
- High ingress protection for harsh environmental conditions
- High EMC resistance according to automotive standards
- Large operating voltage range
Product characteristics
>th >Dimensions [mm]
Electrical design | PNP/NPN |
---|
Output function | normally open |
---|
Sensing range [mm] | 8 |
---|
Housing | |
---|
M18 x 1 / L = 70 |
Application
System | gold-plated contacts; Increased sensing range |
---|
Application | Use in mobile and harsh applications |
---|
Electrical data
Operating voltage [V] | 10...36 DC |
---|
Current consumption [mA] | < 10; (only in 3-wire operation) |
---|
Protection class | II |
---|
Reverse polarity protection | yes |
---|
Outputs
Electrical design | PNP/NPN |
---|
Output function | normally open |
---|
Max. voltage drop switching output DC [V] | 2.5 |
---|
Minimum load current [mA] | 2; (only in 2-wire operation) |
---|
Max. leakage current [mA] | 0.5; (only in 2-wire operation) |
---|
Permanent current rating of switching output DC [mA] | 100 |
---|
Switching frequency DC [Hz] | 200 |
---|
Short-circuit protection | yes |
---|
Type of short-circuit protection | yes (non-latching) |
---|
Overload protection | yes |
---|
Monitoring range
Sensing range [mm] | 8 |
---|
Operating distance [mm] | 0...6.48 |
---|
Increased sensing range | yes |
---|
Accuracy / deviations
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.45 / copper: 0.35 |
---|
Hysteresis [% of Sr] | 1...20 |
---|
Operating conditions
Ambient temperature [°C] | -40...85 |
---|
Protection | IP 67; IP 69K |
---|
Tests / approvals
EMC | Automotive area | | Noise emission and noise interference: ECE R10 | E1 type approval | noise immunity according to DIN ISO 11452-2 | 100 V/m | conducted interference in 24 V networks to ISO 7637-2: 2004 (pulse 1 to 4) and ISO16750-2: 2012 (load dump) | | pulse | 1 2a 2b 3a 3b 4 Load dump | Severity level | III III III III III III Test A | Failure criterion | C A C A A C C | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | EN 61000-4-3 HF radiated | 10 V/m | EN 61000-4-4 Burst | 2 kV | EN 61000-4-5 Surge | 0,5 kV mains line to line | EN 61000-4-6 HF conducted | 10 V | EN 55011 | class B |
|
---|
Vibration resistance | EN 60068-2-6 Fc | 20 g (10...3000 Hz) / -20...50 °C | | 50 sweep cycles per frequency; 1 octave per minute in 3 axes |
|
---|
Shock resistance | EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
|
---|
Continuous shock resistance | EN 60068-2-27 | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
|
---|
Fast temperature changes | EN 60068-2-14 Na | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
|
---|
Salt spray test | EN 60068-2-52 Kb | severity level 5 (4 test cycles) |
|
---|
MTTF [years] | 1192 |
---|
UL approval | Ta | 0...40 °C | Enclosure type | Type 1 | voltage supply | Hazardous voltage | File number UL | E174191 |
|
---|
Mechanical data
>th >Mounting
Weight [g] | 62 |
---|
Housing | |
---|
flush mountable |
Dimensions [mm] | M18 x 1 / L = 70 |
---|
Thread designation | M18 x 1 |
---|
Material | housing: stainless steel; sensing face: LCP natural; LED window: PEI; lock nuts: brass |
---|
Displays / operating elements
Display | Switching status | 4 x 90° LED, yellow |
|
---|
Accessories
Remarks
Electrical connection - plug
| Connector: 1 x M12; coding: A; Contacts: gold-plated |
---|
ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — IGM200-01 — 13.04.2023 —