MPPT 100A Solar Panel Charge Controller 12V/24V/36V/48V Auto 160V Parallel 12Pcs

PowMr Solar Charger Controller MPPT 100A 12V 24V 36V 48V Blacklight LCD Regulator Max PV Input 160VDC Support Lithium batteries

 

 

Introduction:

POW-M100-PRO solar charge controller is based on an advanced maximum power point tracking(MPPT) technology developed, and dedicated to the solar system, the charge controller conversion efficiency is up to 97%.

 

Feature:

* MPPT 100A solar charge controller.

* Innovative MPPT technology with a tracking efficiency of up to 99.9% and a peak conversion efficiency of up to 97%.

* Supports Up to 12 Units in Parallel.

* Built-in DSP controller with high performance.

* Automatic switch for 12V/24V/36V/48V battery bank.

* 3-stage charging optimizes battery performance.

* Overcharge protection, Input PV polarity reverse protection, Output limited current protection.

* Over-temperature protection.

* Troubleshooting promotion function.

* Built-in cooling fan for forced heat dissipation, improving overall device operational efficiency.

* Easy to be mounted.

 

Specification:

 

Models

POW-M100-PRO

Solar Input Specification

Max. Solar Array Open-Circuit Voltage

160V

Maximum Input Power:

 

For 12V System

1200W

For 24V System

2400W

For 36V System

3600W

For 48V System

4800W

Battery Charging Specification

Charging Technology

MPPT

Charging Algorithm

3 Stages

Charging Algorithm

12V/24V/36V/48V

Battery Voltage Range

9~60V

Rated Charging Current

100A

Maximum Efficiency

≤98%

MPPT Efficiency

>99%

Temperature Compensation

-3mV/°C/2V(default)

Self-Consumption

44mA/12V; 26mA/24V; 18mA/36V; 12mA/48V

Environment Specification

Operating Temperature Range

-35°C~+45°C

Humidity Range

≤95%,Non-condensing

Altitude

<3000m

General Specification

Protection Level

IP32

Dimensions

260x180x75mm

Net Weight

2.9kg

 

Mounting information

  1. Battery must be connected first. NEVER connect the solar panel array to the controller without a battery.
  2. Ensure input voltage does not exceed 190 VDC to prevent permanent damage.
  3. Do NOT let the positive (+) and negative (-) terminals of the battery touch each other.
  4. Do NOT connect any inverters or battery charger into the load terminal of the charge controller.
  5. Place the controller on a vertical surface protected from direct sunlight, high temperatures, and water. Make sure there is good ventilation.
  6. Please check for Clearance, verify that there is sufficient room to run wires, as well as clearance above and below the controller for ventilation. The clearance should be at least 3 inches (75mm).
 

 

PushAuction