Feature:

1. The flowmeter control panel adopts modular design, multiple measurement units conversion, complete functions, convenient operation and simple structure.
2. It can be used to measure , kerosene, diesel, fuel, urea water. It is widely used in petroleum, chemical, pharmaceutical, transportation, food and other industries and commercial fields.
3. Digital LCD display, high‑definition display shows instantaneous and cumulative flow and NPT counter.
4. Clear and accurate measurement, intuitive and clear reading, high reliability, measurement accuracy ±1%.
5. 4 unit options, liter (L) / gallon (GAL) / pint (PTS) / quart (QTS), used in different countries. Easy to clean, install and maintain.


Specification:

Item Type: Flow Meter
Material: ABS
Standard: Vertical
Media: , diesel fuel, kerosene, chemical liquid, urea water
Importers: 1in internal thread
Measurement Accuracy: ± 1%
Repeatability: ± 0.5%
Maximum Working Pressure: 20BAR
Operating Voltage: 2.3 - 3.3V
Standby Time: 2 Years
Flow Range: 10 - 120L / MIN
Single Count: 0.00 - 999.9
Total Cumulative Number: 0.00 - 999999.9
Unit: L / L, gal / GAL, pint / PTS, quart / QTS
Single Measurement Cleared: RESET
Battery: Built-in battery, 2 x AAA batteries, 500mAh(include batteries)
Setting Units of Measurement:
1. In the standby mode, or raise the amount of current display state
2. Press CAL + RESET button for 5 seconds
3. Enter unit conversion settings, press the RESET button
4. Followed by LTR - GAL - PT -QT - LTR choose the unit of measurement
5 .While the cumulative filling volume displayed in the current unit of measure conversion after
6. Press the MENU key for 3 seconds to exit the unit conversion settings.
Operating Instructions
1. Measuring Unit Setting
Under standby state or current amount display state, press and hold MENU+RESET buttons for 5 seconds to enter unit conversion setting, then press RESET button to select unit in turn of LTR - GAL - PT - QT - LTR. Press and hold MENU button for 3 seconds to exit unit conversion setting.
2. Accumulative and Current Amount Reset
Press and hold RESET button and LCD screen displays on full screen, wait till the full screen display end then loose the RESET button. At this time the accumulative amount and current amount is reset.
3. Error Coefficient and Accumulative Amount Inquire
Under standby state, press MENU + RESET button together, then LCD display shows the error coefficient on the upper row, and accumulative amount on the lower row.
4. Error Coefficient Calibration
Under standby state or current amount display state, press and hold MENU button for 3 seconds to enter error coefficient calibration mode. The first digit flashes, press MENU button to change position of the digit, and press RESET button to change digit. As this coefficient increases, output oil quantity reduces. Then press and hold MENU button for 3 seconds to end error coefficient calibration and return to current amount display state, and the current amount is reset as zero. The calibration error coefficient range is 0.1000 to 9.9999. For example, original coefficient is 1.000, when it displays 100 liters output of oil, the actual oil output is 100L. If you need 2 liter reduced, set the coefficient as 1.020, then the output would be 98L.
5. Maintenance
When battery voltage is too low, a battery symbol appears on the LCD display, which reminds user to replace battery. Too short battery life can cause damage to the meter because of battery leakage. This meter has designed standby life of about two years, but we suggest customer to replace a battery each year, and check battery electrodes if there is any rust. Battery should be removed if not using flow meter during long time.


Package List:

1 x Flow Meter

1 x Adapter

2 x Rubber Seal Ring


Note:

1. This product requires 2 x AAA batteries, more convenient for you to use, and comes with 2 x AAA batteries replaceable batteries
2. Hint of insufficient battery power: LBAT is displayed when the battery voltage is 2.2V ‑ 2.4V to remind the user to replace the battery.
3. Please note that the new type and old type of this product will be sent randomly, and make sure you will not mind before ordering.
  




 

1. Our listing price includes the value of goods,packaging cost,and export taxes,not including international duties.
2. duties,taxes,and charges are not included in the item price or shipping fee.
3. The duties are buyers' responsibility.Please check with your country's customs office determine what these additional costs will be prior to your purchase.
4. All disputes arising from the duties will be submitted to ebay for solution.

 

1. Any questions, pls. contact us via ebay message or email us.We will reply your message within 48 hours. If you do not receive our reply within 48 hours, pls. post a message again because sometimes our message system may block some emails.

2. If you are satisfied with our service, pls. kindly leave us a positive feedback and give us the Detailed Seller Rating with all "5 " in very area
3. Our aim is to provide Level Customer Service, your recognition will encourage us greatly and serve you better. We strive to keep all our customers satisfy. 

https://image-us.chengykj.com/upload/third_resource/image/feedback.jpg


We will do our up most to exceed your expectations in customer service, communication and dispatching of your orders. 

https://image-us.chengykj.com/upload/third_resource/image/shipc73.jpg

DataCaciques