1pc 12Vdc Digital LED Display Infinite Cycle Delay Timing Loop Relay Module
8 Programmable Operating Cycles 

including
Start on Power-up, Trigger Start, Selectable Number of Cycles from Once to Continuous Loop

Settable Times Cycles for both Off & On from 0.1 sec to 99 hours
Red LED Display for Programming and Count-down
On-board SPDT Relay with LED Activation Indicator

for Model RR Applications

This module features programmable and more concise control times than the other one I sell.  Takes some patience to setup but a great design with great versatility.  One is required for my single smoke generator and two are required for dual smoke generator.  This type of timed On/Off control can be used for many different applications and control any intermittent animation.  It is very hard to find.  Input voltage is 12Vdc.

Fully programmable and very hard to find item!

BUY NOW!
Item ships via USPS Ground Advantage
I will combine shipping whenever possible, but request and wait for invoice with adjusted shipping cost.


Features:

Time delay range: T1 and T2 between 0.1 second ~99 hours adjustable.

P1 (relay on):  when power on, the relay on, delay T1, and the relay off. Give IN a low level, repeat the above function.

P2 (relay off):  when power on, the relay disconnected, delay T1, and the relay on. Give IN a low level, repeat the above function.

P3 (Timing cycle on-off):  when power on, the relay on, delay T1, and the relay off, delay T2, the relay on, and then repeat the above condition, cycle times can be adjusted 1-99 times or infinite loop.

P4 (Timing cycle off-on):  when power on, the relay disconnected, delay T1, and the relay on, delay T2, the relay off, and then repeat the above condition, cycle times can be adjusted 1-99 times or infinite loop.

P5 (trigger relay on):  when power on, the relay disconnected, triggered the relay on, delay T1, and the relay off. Give IN a low level, repeat the above function.

P6 (trigger relay on):  when power on, the relay disconnected, triggered the relay disconnected, delay T1, and the relay on. Give IN a low level, repeat the above function.

P7 (trigger cycle on-off):  when power on, the relay disconnected, triggered the relay on, delay T1, and the relay off, delay T2, and the relay on, and then repeat the above condition, cycle times can be adjusted 1-99 times or infinite loop.

P8 (trigger circle off-on):  when power on, the relay disconnected, triggered the relay disconnected, delay T1, and the relay on, delay T2, and the relay off, and then repeat the above condition, cycle times can be adjusted 1-99 times or infinite loop.

Parameters:

1.  Input Voltage:  DC 12V
2.  Load Power:  DC 0-30V 10A / AC 0-220V 10A
3.  Static current:  15mA
4.  Working current:  30mA
5.  Service life:  100 thousand times
6.  Working temperature:  -40-85;
7.  Size:  65*28*18mm

Setup Instructions:

Step 1:  Power on, connect input voltage

Step 2:  Long press the SET key to enter the function mode, display P1 - P8,
              Short press switch to choose between function P1 to function P8

Step 3:  Press the ADD key to select the T1 time unit, the display value (-0/-1/-2/-3)
               To set the T1 time unit, press the ADD key time unit to switch between -0/-1/-2/-3

     Time unit:  -0:  time range 0 to 9.9s  (time accuracy: 0.1s)
     Time unit:  -1: 1s to 99s  (time accuracy: 1s)
 
    Time unit:  -2:  l min to 99 min  (time accuracy: l min)
     Time unit:  -3:  l hour to 99 hours  (time accuracy:1h)

Step 4:  Press the SET key to set T1 time, display T1, then press ADD/Enter key to add and
              display value (00)  (The add key increases the number and the enter key decreases the number)
                     If it is a function of P1, P2, P5 or P6, press SET key to confirm the save, set
                     If it is a function of P3, P4, P7 or P8, goto step 5

Step 5:  Press the SET key to select the T2 time unit, the display value (-0/-1/-2/-3)
              To set the T2 time unit, press the ADD key time unit to switch between -0/-1/-2/-3  

     Time unit:  -0: time range 0.1s to 9.9s  (time accuracy: 0.1 sec)
     Time unit:  -1: 1s to 99s  (time accuracy: l sec)
     Time unit:  -2: l min to 99 min  (time accuracy: l min)
      Time unit:  -3: l hour to 99 hours  (time accuracy: l hour)

Step 6:  Press the SET key to set T2 time, display T2, then press ADD/Enter key to add and display value (00)

Step 7:  Press the SET key to set the number of cycles, display "C-" then press the ADD/Enter button to add and subtract the number of cycles,                                                                       display value 00  (if set to 0 is infinite loop)

Step 8:  Press the SET key to confirm the preservation


Check out my other items!