Description
RCWL-0516 is a microwave sensor module that uses Doppler radar technology to detect movement of objects.
The module has the characteristics of high sensitivity, long sensing distance, strong reliability, large sensing angle and wide power supply voltage range. Widely used in a variety of human body induction lighting and anti-theft alarm and other occasions.
 
Features:
●Adopt special signal processing control chip RCWL--9196
●Wide operating voltage range: 4.0~28.0V
●Compared with traditional infrared induction PIR, it has penetration detection ability
●Blocking time, distance adjustable
●It can output 3.3V power supply
Pin Definition:
1) 3V3
3.3V output voltage, drive current 100mA.
2) GND
module ground.
3) OUT
Control signal output, when an object moves in the detection area, OUT outputs a high level; C-TM
The repeat trigger time can be set, if there is a trigger signal within the repeat trigger time (an object moves
If there is no moving object in the detection area, it will output a low level.
4) VIN
Module power input, 4-28V.
5) CDS
Trigger control signal; less than 0.7V, OUT- - direct output low level: greater than 0.7V, positive detection
work often.
The CDS pin is connected to a photoresistor, and the module detection function can be turned off at night.
Application design should pay attention to:
1. There must be no metal shielding in front of the sensing surface.
2. A space of more than 1CM should be reserved at the front and rear of the sensing surface.
3. The module and the mounting carrier plane should be as parallel as possible.
4. The application is effective in a certain detection area.
5. The component side of the module is the positive sensing surface, and the reverse side is the negative sensing surface. The negative sensing surface is slightly less effective.
6. The microwave modules cannot be applied on a large scale in the same area, otherwise there will be mutual interference, and the distance between individual modules will be greater than 1M.
Adjustment Part Introduction:
1: C-TM
Adjust the repeated trigger time, the default trigger time is 2S. Increasing capacitance will increase repetition
Trigger time, the actual calculation of repeated trigger time can be done as follows:
Paste the capacitor at C-T1, test the frequency f of pin 3 of 9196, and repeat the trigger time T= (1/F) *32768
2: R-GN
The detection distance is adjusted, and the resistance is connected, and the detection distance becomes smaller. If it is not connected, the detection distance is about 7M. When connected with a 1M resistor, the detection distance is about 5M, and the customer can adjust it according to the actual situation.
3. R-CDS
The internal VCC is connected in parallel with the internal 1M resistor through R-CDS to the CDS pin (ie, the 9 pin of 9196), and the CDs is connected to a photoresistor, which can turn off the module detection function at night. The R-CDS value can be set according to the actual required ambient brightness.
 
Product Introduction:
1.Operating Voltage: 4-28V
2. Operating Current: 2.8mA (typical); 3mA (max)
3. Detection Distance: 5-9m
4.Transmitting Power: 20mW (typical); 30mW (max)
5.Output Voltage:3.2-3.4V
6. Output Voltage Driving Capacity: 100mA
7. Trigger Way: repeat trigger
8. Output Control Low Level: 0V
9. Output Control High Level: 3.3V
10.Operating Temperature:-20~80 celsius
11.Storage Temperature:-40~100 celsius
 
Package Included:
2/4/6/8/10/20 pcs RCWL-0516 Microwave Radar Sensor Switch
 
Note:
Please allow 1-2mm errors due to manual measurement.