Gas: smoke
Detection range: 300 to 10000ppmm
Characteristic gas: 1000ppmm isobutane
Sensitivity: R in air/Rin typical gas≥5
Sensitive body resistance: 1KΩ to 20KΩ in 50ppm toluene
Response time: ≤10s
Recovery time: ≤30s
Heating resistance: 31Ω±3Ω
Heating current: ≤180mA
Heating voltage: 5.0V ± 0.2V
Heating power: ≤900mW
Measuring voltage: ≤24V
Gas may be used in homes and factories leakage monitoring device suitable for the detection of gas, butane , propane , methane , smoke , etc.
Using high-quality dual-panel design, with power indicator and TTL signal output instructions;
The switching signal having a DO (TTL) output and analog output AO ;
TTL output valid signal is low . ( Low-level signal when the output light can be directly connected to the microcontroller or relay module )
Analog output voltage with the higher concentration of higher voltage.
A gas, natural gas, city gas , smoke better sensitivity.
There are four screw holes for easy positioning ;
Has a long life and reliable stability
Rapid response and recovery characteristic
Input voltage : DC5V Power consumption ( current ): 150mA
DO output : TTL digital 0 and 1 ( 0.1 and 5V)
AO output :0.1-0 .3 V ( relative to pollution ) , the maximum concentration of a voltage of about 4V
Special note: After the sensor is powered , needs to warm up around 20S, measured data was stable , heat sensor is a normal phenomenon , because the internal heating wire , if hot is not normal .
VCC: positive power supply (5V)
GND: power supply is negative
DO: TTL switching signal output
AO: analog signal output
MQ-2B
Product description:
Detection gas: combustible gas, smoke
Detection concentration: 300 ~ 10000ppm (combustible gas)
Loop voltage Vc: ≤24V DC
Heating voltage VH : 5.0V ± 0.1V AC or DC
Load resistance RL: adjustable
Heating resistance RH : 29 Ω ± 3 Ω (room temperature)
Heating power consumption PH : ≤900mW
Sensitivity S: Rs (in air) / Rs (2000ppm C3H8) ≥ 5
Output voltage Vs : 2.5V ~ 4.0V (in 2000ppmC3H8)
Concentration slope α: ≤0.6 (R3000ppm/R1000ppm C3H8)
Temperature, humidity: 20 °C ± 2 ° C; 55% ± 5% RH
Standard test circuit: Vc: 5.0V ± 0.1V; VH: 5.0V ± 0.1V
Warm-up time: no less than 48 hours
Oxygen content: 21% (not less than 18%, (oxygen concentration will affect the initial value, sensitivity and repeatability of the sensor, please consult when using at low oxygen concentration)
Life expectancy: 10 years
Note:The figure above shows the basic test circuit for the MQ-2B sensor. The sensor requires two voltages to be applied: heater voltage (VH) and test voltage (VC). The VH is used to provide a specific operating temperature for the sensor, either DC or AC. The VRL is the voltage across the load resistor (RL) of the sensor in series. VC is the voltage for testing the load resistor RL and requires a DC power supply.