Introduction:
This is a multi-function inverter/charger, combining functions of inverter, solar charger, and battery charger to offer uninterruptible power support with portable size.
Feature:
INVERTER MODEL | POW-HVM2H-12V-N | POW-HVM3.2H-24V-N |
Rated Output Power | 2000VA1600W | 3200VA/3000W |
Output Voltage Waveform | Pure Sine Wave | |
Output Voltage Regulation | 230Vac±5% | |
Utility Charging Mode | ||
INVERTER MODEL | 2.0KW 12V | 3.2KW 24V |
Charging Algorithm | 3-Step | |
AC Charging Current (Max) | 60 Amp | |
Bulk Charging Voltage | ||
INVERTER MODEL | 2.0KW 12V | 3.2KW 24V |
Flooded Battery | 14.6 | 29.2 |
AGM / Gel Battery | 14.1 | 28.2 |
Floating Charging Voltage | 13.5Vdc | 27.0Vdc |
MPPT Solar Charging Mode | ||
Max. PV Array Power | 2000W | 3000W |
Nominal PV Voltage | 240Vdc | |
PV Array MPPT Voltage Range | 30~400Vdc | 30~400Vdc |
Max. PV Array Open Circuit Voltage | 400Vdc | 400Vdc |
Max Charging Current (AC charger+solar charger) | 80Amp | |
INVERTER MODEL | 2.0KW 12V | 3.2KW 24V |
Safety Certification | CE | |
Operating Temperature Range | -10±C to 50±C | |
Storage temperature | -15±C~ 60± C | |
Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
Input Voltage Waveform | Sinusoidal (utility or generator) | |
Nominal Input Voltage | 230Vac | |
Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | |
Low Loss Return Voltage | 180Vac±7V (UPS); | |
100Vac±7V (Appliances) | ||
High Loss Voltage | 280Vac±7V | |
High Loss Return Voltage | 270Vac±7V | |
Max AC Input Voltage | 300Vac | |
Nominal Input Frequency | 50Hz/ 60Hz (Auto-detection) | |
Low Loss Frequency | 40±Hz | |
Low Loss Return Frequency | 42±Hz | |
High Loss Frequency | 65±Hz | |
High Loss Return Frequency | 63±Hz | |
Output Short Circuit Protection | Circuit Breaker | |
Efficiency (Line Mode) | >95% ( Rated R load, battery full charged ) | |
Transfer Time | 10ms typical (UPS); | |
20ms typical (Appliances) | ||
INVERTER MODEL | 2.0KW 12V | 3.2KW 24V |
Output Frequency | 50Hz/ 60Hz (Auto-detection) | |
Peak Efficiency | 94% | |
Overload Protection | 5s@ >150% Io ad; 10s@ 110% ~ 150% Io ad | |
Surge Capacity | 2* rated power for 5 seconds | |
Nominal DC Input Voltage | 12Vdc | 24Vdc |
Cold Start Voltage | 11.5Vdc | 23.0Vdc |
Low DC Warning Voltage | ||
@ Io ad < 50>% | 11.0Vdc | 22.0Vdc |
@ load >50% | 10.5Vdc | 21.0Vdc |
Low DC Warning Return Voltage | ||
@ load < 50% | 11.5Vdc | 22.5Vdc |
@ load >50% | 11.0Vdc | 22.0Vdc |
Low DC Cut off Voltage | ||
@ load < 50% | 10.2Vdc | 20.5Vdc |
@ load >50% | 9.6Vdc | 20.0Vdc |
High DC Recovery Voltage | 14.0Vdc | 32Vdc |
High DC Cut-off Voltage | 16.0Vdc | 33Vdc |
No Load Power Consumption | <25W | <35W |
3 Load Working Mode:
Solar and battery energy will provide power to the loads only when utility power is not available.
If solar energy is not sufficient to power all connected loads, battery energy will supply power the loads at the same time.
If solar energy is not sufficient to power all connected loads, battery energy will supply power to the loads at the same time.
1. In utility bypass mode, the device cannot be connected to two-phase 220V AC, i.e. L1-L2 cannot be connected to L-N.
2. 2. In inverter mode, after the device is connected to two-phase 220V, please do not select utility priority for the output priority, so as not to cause safety hazards to the device.
3. Please do not connect the AC output of the device to the autotransformer, so as not to affect the normal service life of the device.