Product Description
Flexible coil fixed by cable ties
Rogowski coils have been used for the detection and measurement of electric currents for decades. They are based on a simple principle: an “air-cored” coil is placed around the conductor in a toroidal fashion and the magnetic field produced by the current induces a voltage in the coil.

Feature 
・High linearity from 1Ato 1000A ・Wide dynamic range ・Very useful with large size or awkward shaped conductors or in places with limited access ・No danger from open-circuited secondary ・Not damaged by large overloads ・Non-intrusive, no power drawn from the main ・Measurement uniformity at any position of the conductor inside the coil ・Excellent degree of rejection to the external current conductor

Advantage•Calibrated to 0.5% •8mm section easy to install •Easy to fixed on bus-bar and cable by cable ties •Lower zero drift down to 0.1mVRelated ProductsS1 D1 S9 SW A01 A05 ME631 ME437
Applications
•Measuring devices, lab instrumentation •Power monitoring & control systems •DC ripple measurement •Harmonics and transients monitoring •Power meter,Power analyzer sensor
Size Information
Specification
Model
NRC-100
NRC-150
NRC-200
Window size
100mm
150mm
200mm
Reference Rated current
1000A
3000A
6000A
Weight
Approx 140-160g
Ratio
85mV/kA@50Hz or 50mV/kA@50Hz
Read Accuracy
Calibrated <0.5% (central position, 25°C) Uncalibrated < 5% tolerance (central position, 25°C)
Maximum current measurable
100kA
Coil Resistance
from 100 to 250 Q
Coil Section
8mm
Lead length
2 meter
Temperature
Calibrated 300ppm/C
Position Error
±1% maximum
Output on 0A (zero drift)
<0.1 mV
Linearity
±0.2% of reading
Bandwidth
1Hz to 100kHz(-3dB)
Operating temperature
-30 °C to 80 °C
Storage temperature
-40 °C to 90 °C
Certificate
IP68
Other requirements,please contact us to OEM.

Size Information
Specification
Model
NRC-100
NRC-150
NRC-200
Window size
100mm
150mm
200mm
Reference Rated current
1000A
3000A
6000A
Weight
Approx 140-160g
Ratio
85mV/kA@50Hz or 50mV/kA@50Hz
Read Accuracy
Calibrated <0.5% (central position, 25°C) Uncalibrated < 5% tolerance (central position, 25°C)
Maximum current measurable
100kA
Coil Resistance
from 100 to 250 Q
Coil Section
8mm
Lead length
2 meter
Temperature
Calibrated 300ppm/C
Position Error
±1% maximum
Output on 0A (zero drift)
<0.1 mV
Linearity
±0.2% of reading
Bandwidth
1Hz to 100kHz(-3dB)
Operating temperature
-30 °C to 80 °C
Storage temperature
-40 °C to 90 °C
Certificate
IP68
Other requirements,please contact us to OEM.