This is a multi-function 48V inverter charger, combining functions of inverter, MPPT solar charger, and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easily accessible button operations such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
NOTE 1: This is a wide voltage Hybrid inverter. Solar panel input voltage must be higher than 150V so that can start up the inverter to work.
NOTE 2: This Hybrid Inverter supports the WIFI function, but need to buy the WIFI module connected to the APP so that can monitor it.
NOTE 3:For 110/120V US home appliances Devices, you can simply add a Transformer (not includes) which stepping down 220/240V AC power to 110/120V AC Power, then your 110V home appliances is also ok to use at the same time, this inverter can't output 110V power, this is a Single-phase 220V output inverter.
Features
Line Mode Specifications | |
INVERTER MODEL | POW-HVM6.2K-48V-LIP (Parallel 12 unit) |
Input Voltage Waveform | Sinusoidal (utility or generator) |
Nominal Input Voltage | 230Vac |
Low Loss Voltage | 170Vac±7V (UPS) 90Vac±7V (Appliances) |
Low Loss Return Voltage | 180Vac±7V (UPS); |
100Vac±7V (Appliances) | |
High Loss Voltage | 280Vac±7V |
High Loss Return Voltage | 270Vac±7V |
Max AC Input Voltage | 300Vac |
Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
Low Loss Frequency | 40±1Hz |
Low Loss Return Frequency | 42±1Hz |
High Loss Frequency | 65±1Hz |
High Loss Return Frequency | 63±1Hz |
Output Short Circuit Protection | Line mode: Circuit Breaker Battery mode: Electronic Circuits |
Efficiency (Line Mode) | >95% ( Rated R load, battery full charged ) |
Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
Inverter Mode Specifications | |
INVERTER MODEL | 6.2KVA |
Rated Output Power | 6.2KVA/6.2KW |
Output Voltage Waveform | Pure Sine Wave |
Output Voltage Regulation | 230Vac±5% |
Output Frequency | 60Hz or 50Hz |
Peak Efficiency | 94% |
Overload Protection | 5s@>140% load; 10s@100%~140% load |
Surge Capacity | |
Nominal DC Input Voltage | 48Vdc |
Cold Start Voltage | 46.0Vdc |
Low DC Warning Voltage | |
@ load < 20% | 44.0Vdc |
@ 20% < load < 50% | 42.8Vdc |
@ load > 50% | 40.4Vdc |
Low DC Warning Return Voltage | |
@ load < 20% | 46.0Vdc |
@ 20% < load < 50% | 44.8Vdc |
@ load > 50% | 42.4Vdc |
Low DC Cut-off Voltage | |
@ load < 20% | 42.0Vdc |
@ 20% < load < 50% | 40.8Vdc |
@ load > 50% | 38.4Vdc |
Charge Mode Specifications | |
Utility Charging Mode | |
INVERTER MODEL | 6.2KVA |
AC Charging Current (Max) | 100Amp (@ VI/P=230Vac) |
Bulk Charging Voltage | |
Flooded Battery | 58.4Vdc |
AGM / Gel Battery | 56.4Vdc |
Floating Charging Voltage | 54Vdc |
Overcharge Protection | 63Vdc |
Charging Algorithm | |
Solar Input | |
INVERTER MODEL | 6.2KVA |
Rated Power | 6200W |
Max. PV Array Open Circuit Voltage | 500VDC |
PV Array MPPT Voltage Range | 120-450VDC |
Max. Input Current | 18A |
General Specifications | |
INVERTER MODEL | 5.5KVA |
Safety Certification | CE |
Operating Temperature Range | -10°C to 55°C |
Storage temperature | -15°C to 60°C |
Humidity | 5% to 95% Relative Humidity (Non-condensing) |
Dimension (D*W*H), mm | 448x295x105 |
Net Weight, kg | 12.5 |
This inverter has a parallel function, which can be Two inverters in parallel; Three inverters in parallel; Four inverters in parallel; Five inverters in parallel; Six inverters in parallel; or Seven inverters in parallel.... Up to 12 inverters can be paralleled
For parallel model installation and operation, please check the parallel installation guide for the details.