Hot Sale

Description:

Introducing our versatile 8-inch patient monitor designed for adult, pediatric, and neonate monitoring. With abundant monitoring functions, this device ensures comprehensive care. Monitor ECG, RESP, SpO2, PR, NIBP, and TEMP effortlessly on the intuitive 8'' TFT color LCD touch screen. Stay up-to-date with PVI (Pleth Variability Index) and export data conveniently via USB. Connect wirelessly or by wire for Nurse Call and easily link to CMS with the USB WIFI module. Experience exceptional digital SpO2 performance alongside human voice alarms. Store 720 hours of trend data and 12 hours of waveforms, while choosing from 16 languages for a personalized experience. Elevate patient care with this reliable 6-parameter signs monitor.

Packing List:

Package Include: 1×Patient Monitor 1×NIBP Cuff 1×SpO2 Probe 1×5 EKG?Cable 1×Temperature Probe 1×NIBP extension cable 5×Electrode 1×User Manual

ECG

:5 Leads, I, II, III, AVR, AVL, AVF, V

Gain:0.25, ´0.5, ´1, ´2

Heart rate:

Adult:15 ~ 300 bpm

Neonatal/Pediatric:15 ~ 350 bpm

Accuracy:1%

Resolution:1 bpm

Sensitivity:> 200 μV P-P

Differential Input Impedance:> 5 M ohm

Electrode offset potential:300mV

Leakage Current:< 10 μA

PACE pulse detect 

Range:±2±700mV

Width:0.12ms

rise time:10100µs

PACE pulse rejection

Range:±2±700mV

Width:0.12ms

rise time:10100µs

ST measurement

Range;-2.0 ~ +2.0 mV

Accuracy:-0.8mV+0.8mV:

±0.02mV or ±10%, which is greater

Respiration

Method:Impedance between RA-LL or RA-LA

Differential Input Impedance:>2.5 M ohm

Respiration Impedance Range:0.3~3Ω

Base Impedance Range:200Ω-2000Ω

Bandwidth:0.3 ~ 2 Hz

Gain:×0.25,×0.500,×1,×2,×4

Respiration Rate

Measurement Range

Adult:0 ~ 120 BrPM

Neonatal / Pediatric: 0 ~ 150 BrPM

Resolution: 1 BrPM

Accuracy

06 BrPM: unspecified

7150 BrPM: ±2 BrPM or ±2%, the greater

Inspiriting current:< 300 µA RMS max

Apnea Alarm:10 ~ 40 s

Temperature

Channel:1

Measure and Alarm Range:0 ~ 50 °C

Resolution:0.1°C

Accuracy:± 0.2℃

NIBP

Pulse Rate Range:40 ~ 240 bpm

Measure and Alarm Range

Adult Mode

SYS:40 ~ 280 mmHg

DIA:10 ~ 220 mmHg

MEAN:20 ~ 240 mmHg

Pediatric Mode

SYS:40 ~ 220 mmHg

DIA :0 ~ 160 mmHg

MEAN:20 ~ 170 mmHg

Neonatal Mode

SYS:35 ~ 135 mmHg

DIA:10 ~ 100 mmHg

MEAN:20 ~ 110 mmHg

Static pressure accuracy:3mmHg

Resolution:1mmHg

Accuracy

Maximum Mean error:5mmHg

Maximum Standard deviation:8mmHg

Over pressure Protection

Adult:300 mmHg

Pediatric:240 mmHg

Neonatal:150 mmHg

SpO2

Measurement Range:0 ~ 100 %

Resolution:1 %

Accuracy

2 % for 70% ~ 100%

0% ~ 69% unspecified

Pulse Rate

Measure and Alarm Range:20~250bpm

Resolution:1bpm

Accuracy:3bpm

Payment
    We accept PayPal only. We will ship out the item after receiving cleared payment.

Shipping

    A complete and correct shipping address is essential.
    Customers with shipping addresses outside of the U.S. are responsible for all duties and import taxes. Please contact your customs for information

Return Policy
    All items are in brand new condition unless specified.

FDA declaration:

    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser.If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.All of our products are CE approved. Please kindly check the copy of the certificate in the listing below.(Rose-China-Beijing-86-13578947868)

This item has been cleaned and treated according to the manufacturer's instructions.

510(K)Number: K161892

Contact Us
    Any questions, please contact us through eBay message or e-mail, We will reply within 1-2 business days (public holidays not included).
    working time: Monday - Friday   9:00 AM - 5:30PM (Beijing)

New Arrival