Model | ST-H1210 | ST-H1220 | ST-H1230 |
To adapt to the battery voltage | 12V/24V Adaptive(Battery<16V;12V Stsyem Battery>18V;24V System) | ||
Rating charger voltage | 50V | ||
Rating charger current | 10A | 20A | 30A |
Recommended power of solar panel |
12V Open-loop Voltage 18-24V Standard Solar Panel 150W*1 24V Open-loop Voltage 36-48V Standard Solar Panel 300W*1 |
||
Recommended number of solar panel |
1 Pieces in parallel | 2 Pieces in parallel | 3 Pieces in parallel |
Charging way | Intelligent Charging MPPT Maximum Power Point tracking | ||
Constant voltage charging voltage | Default:14.2V(24V battery*2)parameters can be set in menu /Quick switch availabe | ||
Constant current charging current | 10A | 20A | 30A |
Under-voltage Protection voltage | Default:10.5V(24V battery*2)parameters can be set and adjusted in menu | ||
Owe pressure recovery voltage | Default:12.5V(24V battery*2)parameters can be set and adjusted in menu | ||
Battery charge voltage summer and winter temperature compensation |
16mV/°C @12V | 32mV/°C @24V | |
Load overload automatic Recovery time | 30s | ||
DC output | 5V 2.1A | ||
Double USB output | 9V/10.5V/12V 1A Output voltage can be remotely controlled | ||
Stand-by power consumption | <20mA | ||
Operating temperature range | -20°C~55°C | ||
Overall dimensions | 208mm*127mm*53mm | ||
Installation of fixed size | 192mm*96* | ||
Product weight(G.W) | 0.52kg | 0.54kg | 0.56kg |