The FRENIC-Ace is a high performance, full-featured Drive designed to suit a wide variety of applications including fans, pumps, specialized machinery and more. Equipped with 200 steps of customizable logic and PMAC motor control, the FRENIC-Ace provides compact, but powerful multi-rated specification solutions for virtually all AC drive applications and comes standard with an industry-leading 3-year warranty.

SPECIFICATIONS

Nominal Motor HP [kW]40 Hp [30 kW] (HND - Variable Torque)
30 Hp [22 kW] (HHD - Constant Torque)
Rated Output Capacity kVA44 kVA (HND)
34 kVA (HHD)
Rated Output Voltage3 Phase, 200-240 Volt (with AVR)
Rated Output Current115 Amps (HND)
90 Amps (HHD)
Rated Overload Capability120 % of nominal current for 1 minute (HND)
150 % of nominal current for 1 minute or 200% of nominal current for 0.5 seconds (HHD)
Main Power Supply Input3 Phase, 200 to 240 Volt, 50/60 Hz (With AVR)
Voltage / Frequency VariationsVoltage: +10 % to -15%
Voltage Unbalance: 2% or less
Frequency: +5% to -5%
Rated Current Input without DC Reactor
[with DC Reactor]
151 Amps [114 Amps] (HND)
112 Amps [84.4 Amps] (HHD)
Required Power Supply Capacity40 kVA (HND)
30 kVA(HHD)
Braking Torque15 % (HND)
20 % (HHD)
DC BrakingStarting frequency: 0.1 to 60.0 Hz
Braking Time: 0.0 to 30.0 Seconds
Braking Level: 0 to 80 % (HND), 0-100 % (HHD) of nominal current
Braking ChopperBuilt-In
Braking ResisterOptional
Minimum Connectable Resistance4 ?
DC Reactor
CoolingFan Cooling
Braking TransistorBuilt-in
EMC FilterOptional
List Price$2,350
Dimensions9.84" x 15.75" x 7.68"
Weight22 lbs
Warranty3 Years

ENVIRONMENTAL

EnclosureIP20, UL Open Type

Ambient TemperatureStandard (Open Type): -10 to +50 °C / 14 to 122 °F (HHD/HND)
NEMA 1/UL Type 1: -10 to+40 °C / 14 to 104 °F (HHD/HND)
Storage Temperature-25 to +65°C (-13 to 149 °F)
Humidity5 to 95% Relative Humidity (without condensation)
Installation LocationIndoors
Altitude<3,300ft (1,000m)
1000-1500m .97 Output Current Derating Factor
1500-2000m .95 Output Current Derating Factor
2000-2500m .91 Output Current Derating Factor
2500-3000m .88 Output Current Derating Factor

CODES AND STANDARDS

UL / cUL 508C C22.2 No.14
CE
RoHs
GOST-R
KC
EN / ISOc13849-1:2008 cat. 3/PL:e

ELECTRICAL

ControlV/F Control
V/F Control with Slip Compensation
Dynamic Torque Vector Control
V/F Control with Encoder (Optional)
Vector Control with Encoder (Optional)
PM Motor Sensorless Vector Control
Output StabilityAnalog setting: +/-0.2% of maximum frequency
Digital setting: +/-0.01% of maximum frequency (by keypad settings)
Output FrequencyMax 500Hz
Speed Control Range1:1500 IM Vector Control w/encoder
1:100 IM V/F w/encoder
1:10 PM Sensorless Vector Control
Digital Inputs(7) X1 - X5, FWD, & REV Programmable, 60 selectable functions
Analog Inputs(1) -0 to +10Vdc
(1) -4 to 20mA
Digital Outputs(1) From C Relay
(2) Transistor Output, 78 Selectable Functions
Analog Output: Selectable Type(2) 0 to 10Vdc or 4 to 20mA, 19 Selectable Output Signal Functions.
RS-485 Connections(2) RJ45 Port Terminal
Operator's Keypad with LED DisplayIndicating System Operation and Associated Value Conversion, Status of I/O, Operations and Alarms
Keypad IndicationsOperations, Number of times unit placed in operation, Duration and kWh output
24Vdc Output Terminal100mA Maximum Supply

*High Carrier Frequency Normal Duty 
  High Carrier Frequency Heavy Duty