P-1: Delayed disconnection: The relay is switched on when the power is on. After a delay of T1, the relay is disconnected. Give IN a low level and repeat the function more than once;
P-2: Delayed pull-in: power-on starts to delay, after delay T1, the relay pulls in; give IN a low level, repeat the function
P-3: Cycle on and off: the power-on relay pulls in, after a delay of T1, the relay is off, after a delay of T2, the relay pulls in, and then repeats the last state, the number of cycles can be adjusted 1-99 times or infinite cycle;
P-4: Cycle on and off: delay when power on, after delay T1, the relay is closed, after delay T2, the relay is off, and then repeat the last state, the number of cycles can be adjusted 1-99 times or infinite cycle
P-5: Trigger delayed pull-in: the relay does not pull-in when the power is on, the relay pulls-in after the trigger, after a delay of T1, the relay is disconnected. Give IN a low level, repeat the function more than once;
P-6: Trigger delay time off: the relay does not pull in when the power is on, the relay does not pull in after the trigger, after the delay T1, the relay pulls in; give IN a low level, repeat the function
P-7: Trigger cycle on and off: the energized relay does not pull in, after triggering, the relay pulls in, after delay T1, the relay is off, after delay T2, the relay pulls in, and then repeats the last state, the number of cycles is adjustable 1-99 times or infinite loop;
P-8: Trigger cycle on and off: the relay does not pull in when the power is on, the relay does not pull in after triggering, after a delay of T1, the relay pulls in, after a delay of T2, the relay pulls in, and then repeat the last state, the number of cycles can be Adjust 1-99 times or infinite loop;
Simple setting, convenient and quick operation!
Product parameters:
1: Working voltage: DC 5V, 12V, 24V
3: Output capacity: can control equipment within DC 30V10A or AC 220V10A
4: Quiescent current: 15mA Working current: 30mA
5: Service life: "100,000 times; working temperature: -40~85'C; size: 65mm*28mm*18mm
Operation instructions:
Step 1: Power on,
Step 2: Long press the SET button to enter the function selection, display P1-P8, short press the SET button to switch between function 1 and function 8.
Step 3: Press the ADD button to select the T1 time unit, display the value (-0/1/2/3), set the T1 time unit, and press the ADD button to switch the time unit between 0/1/2/3. .
Time unit: -0: 0.1 second file, time range 0.1 second -9.9 second
-1: 1 second gear, time range 1 second -99 seconds
-2: 1 minute gear, time range 1 minute -99 minutes
-3: 1 hour gear, time range 1 small clock -99 hours
Step 4: Press the SET key to set the T1 time and display T1. At this time, press the ADD/Enter key to increase or decrease the time and display the value (00).
If it is function 1, 2, 5, 6, press the SET key to confirm and save, and the setting ends.
If it is function 3, 4, 7, 8 then enter the fifth step.
Step 5: Press the SET key to set the T2 time unit. Display "-0/1/2/3", set the T2 time unit, and press the ADD key to switch the time unit between 0/1/2/3. .
Time unit: -0: 0.1 second file, time range 0.1 second -9.9 second
-1: 1 second gear, time range 1 second -99 seconds
-2: 1 minute gear, time range 1 minute -99 minutes
-3: 1 hour gear, time range 1 small clock -99 hours
Step 6: Press the SET key to set the T2 time and display "T2". At this time, press the ADD/Enter key to increase or decrease the time and display the value (00).
Step 7: Press the SET key to set the number of cycles and display "C-". At this time, press the ADD/Enter key to increase or decrease the number of cycles and display the value (00). If it is set to 0, it is an infinite cycle.
Step 8: Press SET to confirm and save.