UCT1102 (16U477) This item has been restricted from sale in the following states: California
Capacitor-start/run pool and spa pump AC motors have a main winding and an auxiliary winding with both a start capacitor and a run capacitor for additional power during startup for higher torque and higher operating efficiency.
- ItemPool Pump Motor
- Motor ApplicationPump
- Motor Sub ApplicationPool and Spa Pump
- PhaseSingle
- Motor DesignCapacitor-Start/Run
- HP1
- Nameplate RPM3,450
- No. of Speeds1
- Voltage115/230V AC
- Full Load Amps11.0/5.5
- Frame56J
- Usable @ 208VNo
- Usable @ 200VNo
- Hz60
- Motor Service Factor1
- Motor Thermal ProtectionAuto
- Ins. ClassB
- Max. Ambient Temp.50 Degrees C
- Duty CycleContinuous
- Motor Shaft RotationCCWSE
- Motor Enclosure DesignOpen Dripproof
- Motor Mounting TypeFace
- Motor Mounting PositionHorizontal
- Motor Frame MaterialSteel
- FinishBlack
- Shaft Dia.5/8 in
- Shaft Length2 9/16 in
- Shaft MaterialStainless Steel
- Motor Shaft DesignThreaded
- Conduit Box PositionF3
- Bolt Circle Dia.5 15/16 in
- Motor BearingsBall
- Height5 5/8 in
- Overall Length14 1/4 in
- Length Less Shaft11 11/16 in
- Body Dia.5.7 in
- Weight25 lb
- Motor Efficiency GroupEnergy Efficient
- StandardsCSA, UL
SK1072 (5PE43) This item has been restricted from sale in the following states: Arizona, California, and Florida
Capacitor-start pool and spa pump AC motors use a capacitor to provide additional power during startup for higher starting torque. This higher torque allows these single-phase motors to move heavier loads at lower speeds, allowing them to be more efficient than split-phase motors.
- ItemPool Pump Motor
- Motor ApplicationPump
- Motor Sub ApplicationPool and Spa Pump
- PhaseSingle
- Motor DesignCapacitor-Start
- HP3/4
- Nameplate RPM3,450
- No. of Speeds1
- Voltage115/230V AC
- Full Load Amps14.6/7.3
- Frame56C
- Usable @ 208VNo
- Usable @ 200VNo
- Hz60
- Motor Service Factor1.5
- Motor Thermal ProtectionAuto
- Ins. ClassB
- Max. Ambient Temp.50 Degrees C
- Duty CycleContinuous
- Motor Shaft RotationCCWSE
- Motor Enclosure DesignOpen Dripproof
- Motor Mounting TypeFace
- Motor Mounting PositionHorizontal
- Motor Frame MaterialSteel
- FinishBlack
- Shaft Dia.5/8 in
- Shaft Length2 1/16 in
- Shaft MaterialStainless Steel
- Motor Shaft DesignKeyed
- Bolt Circle Dia.5 13/16 in
- Motor BearingsBall
- Height5 9/16 in
- Overall Length13 5/8 in
- Length Less Shaft11 9/16 in
- Body Dia.5.7 in
- Weight22 lb
- Motor Efficiency GroupStandard Efficient
- StandardsCSA, UL
CENTURY FC1066AF
- ItemCondenser Fan Motor
- Motor ApplicationHVAC/R
- Motor Sub ApplicationCondenser Fan
- PhaseSingle
- Motor DesignPermanent Split Capacitor
- HP5/8
- Nameplate RPM1,075
- No. of Speeds1
- Voltage200-230/460V AC
- Full Load Amps4.0/2.0
- Frame48Y
- Output Watts450 W
- Hz60
- Usable @ 208VYes
- Usable @ 200VYes
- Motor Service Factor1
- Motor Thermal ProtectionAuto
- Ins. ClassF
- Duty CycleContinuous
- Max. Ambient Temp.70 Degrees C
- Motor Shaft RotationCW/CCW
- Motor Enclosure DesignOpen Air-Over
- Motor Mounting TypeBand/Stud
- Motor Frame MaterialSteel
- Motor Mounting PositionVertical Shaft Up
- Shaft Length3 5/8 in
- Lead Length5 in
- Shaft Dia.1/2 in
- Removable BaseYes
- Conduit Box LocationExterior
- Conduit Box PositionF1
- Motor BearingsBall
- Body Dia.5 5/8 in
- Motor Shaft DesignKeyed
- Overall Length12 15/16 in
- Length Less Shaft9 5/16 in
- FeaturesBelly Band, Thermally Protected, Vertical Shaft Up
- Weight19 lb
- Motor Efficiency GroupStandard Efficient
- StandardsCSA Certified, UL Recognized
- Capacitor Required2MDY7
Room Air Conditioner Motor, 1/15, 1/20, 1/30, 1/50 HP, Shaded Pole, Nameplate RPM 1,050 389A 4UU37
Technical Specs
- ItemRoom Air Conditioner Motor
- Motor ApplicationHVAC/R
- Motor Sub ApplicationRoom Air Conditioner
- PhaseSingle
- Motor DesignShaded Pole
- HP1/15, 1/20, 1/30, 1/50
- Nameplate RPM1,050
- No. of Speeds4
- Voltage115V AC
- Full Load Amps2.4, 1.60, 1.10, 0.80
- Frame42Y
- Usable @ 208VNo
- Usable @ 200VNo
- Motor Thermal ProtectionAuto
- Hz50 Hz
- Motor Service Factor1
- Ins. ClassA
- Motor Shaft RotationCCWLE
- Max. Ambient Temp.40 Degrees C
- Lead Length54 in
- Motor Enclosure DesignOpen Air-Over
- Motor Mounting TypeStud
- Motor Mounting PositionHorizontal
- Number of Shafts2
- Motor Frame MaterialSteel
- Shaft Dia.1/2 in
- Shaft Length10 1/2 in
- Motor BearingsSleeve
- Motor Shaft DesignFlat
- Overall Length25 in
- Length Less Shaft4 in
- Mounting Holes(4) #8-32
- Body Dia.5 in
- Stud Quantity4
- Weight9 lb
- Mounting Stud Pattern2-5/16 in x 4 in
- Bolt Circle Dia.4 5/8 in
- Stud Size#8-32
- Ring to Ring Center4 to 5 in
- Resilient Ring Dia.2 1/4 in
- StandardsCSA, UL
- Capacitor RequiredNo