Features:
1. Wide voltage supply 5~30V ;
2. Clear and simple interface, powerful and easy to understand, meet almost all your needs;
3. Has a key emergency stop function (STOP key), with reverse connection protection, reverse connection does not burn;
4. You can set different OP, CL, LOP parameters, these parameters are independent of each other and are saved separately;
5. All set parameters are automatically saved by power down;
6. 0.1 seconds (small) ~ 999 minutes (large) continuously adjustable;
7. Board size:65*34mm Weight:25g
8. The delay timing relay module is equipped with a high performance 8-bit microprocessor, also on board 3-bit high bright digital tube can display the timing time in real time, the module can be used to control solenoid valves, motors, light strips, product aging test and many other occasions.
Note: The voltage should not exceed 20V as far as possible, because the linear voltage regulator has a low efficiency and a high differential voltage, the temperature will be high and bad heat dissipation will be possible.
Specification:
1):Working voltage:5--30V(anti-reverse connection)
2):Trigger signal source: high level trigger (3.0V-24V) signal ground and system ground not common ground to improve the system's anti-interference ability (can also be shorted to common ground)
3):Output capacity: can control equipment within 30V 5A DC or 220V 5A AC
4):Quiescent current: 20mA Operating current: 50mA
5):Service life:more than 100,000 times;Size:65*34*17mm
6):With optocoupler isolation, enhanced anti-interference ability, industrial grade circuit board, set parameters after power failure forever memory.
Instructions for use:
1. Working mode
P1: After the signal is triggered, the relay is on for OP time and then off; during the OP time, the following operation
P1.1: Signal triggered again is not valid;
P1.2: Signal is triggered again to re-timer;
P1.3: the signal is triggered again to reset, the relay is disconnected and the timing is stopped;
P2.1: After giving the trigger signal, the relay is disconnected for CL time, the relay is switched on for OP time and the timing is completed, then the relay is disconnected;
P3.1: after giving the trigger signal, the relay is switched on for OP time, the relay is switched off for CL time, then the above action is cycled, the signal is given again within the cycle, the relay is switched off and the timing is stopped; the number of cycles (LOP) can be set;
P3.2: After power-up, without trigger signal, the relay is switched on for OP time, the relay is switched off for CL time and then the above action is cycled; the number of cycles (LOP) can be set;
P4.1: Signal hold function: if there is a trigger signal, the timing is cleared and the relay remains on; when the signal disappears, the relay is disconnected after the timing OP; during the timing period, when there is a signal again, the timing is cleared;
Package List
1x Relay module