Specification
|
AC voltage (40 Hz ~500Hz)1
|
Range
|
Resolution
|
Accuracy
|
6.000 V 60.00 V 600.0 V
|
0.001 V 0.01 V 0.1 V
|
1.0 % + 3
|
DC voltage
|
6.000 V 60.00 V 600.0 V
|
0.001 V 0.01 V 0.1 V
|
0.5 % + 3
|
AC millivolt
|
600.0 mV
|
0.1 mV
|
3.0 % + 3
|
Diode test 2
|
2.000 V
|
0.001 V
|
10%
|
Resistance (Ohms)
|
400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ
|
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ
|
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3
|
Capacitance 3
|
50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF
|
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF
|
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5
|
Frequency 4 Hz (10 Hz ~ 100 kHz)
|
50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz
|
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz
|
0.1 % + 3
|
Duty 4
|
1 % ~ 99 %
|
0.10%
|
1 %, Typical condition
|
AC current
(40 Hz ~ 200 Hz)
|
4.000 A 10.00 A
|
0.001 A 0.01 A
|
1.5 % + 3
|
DC current
|
4.000 A 10.00 A
|
0.001 A 0.01 A
|
1.5 % + 3
|
*Typical condition refers to the one when the frequency is 50 Hz or 60 Hz and duty is 10% ~ 90%.
|
Function
|
Overload protection
|
Input impedance(Nominal value)
|
CMRR
|
Normal Mode Rejection Ratio
|
AC voltage
|
600 V1
|
>10 MΩ <100 pF2
|
In DC current of 50 Hz or 60 Hz, > 60 dB
|
−
|
AC millivolt
|
600 mV
|
>1M, <100 pF
|
When 50 Hz or 60 Hz, >80 dB
|
−
|
DC voltage
|
600 V1
|
>10 MΩ <100 pF
|
In DC current of 50 Hz or 60 Hz, >100 dB
|
When 50 Hz or 60 Hz, >60 dB
|
1. Maximum 6 x 105 V Hz
2. For Medium Voltage(AC),Input impedance is about 1 MΩ.
|
General Specifications
|
Maximum voltage stressed on any terminals or ground line
|
600 V
|
Display (LCD)
|
6000 times,update 3 times per second
|
Battery Type
|
2 * AAA battery(NEDA 24A,IEC LR03)(Maybe not included in the package)
|
Battery life
|
At least 200 hours
|
Temperature
|
Operating Temperature
|
0 °C ~ 40 °C
|
Storage Temperature
|
-30 °C ~ 60 °C
|
Relative humidity
|
Humidity
|
When it is less than 10°C, there is no condensation;
10 °C ~30 °C, ≤ 90 %; 30 °C ~ 40 °C, ≤ 75 %
|
Humidity, 40 MΩ Range
|
10 °C ~ 30 °C, ≤ 80 %;30 °C ~ 40 °C, ≤ 70 %
|
Altitude
|
Operating Altitude
|
2000 m
|
Storage Altitude
|
12000 m
|
Temperature Coefficient
|
0.1 X(Specified accuracy)/°C (<18 °C or >28 °C)
|
Current input fuse protection
|
11A,1000V Fast-blow, must use the specified Fluke parts
|
Size(H x W x L)
|
142 mm x 69 mm x 28mm
|
Weight
|
200 g
|
Protection class
|
IEC 60529:IP 40
|
Security
|
IEC 61010-1: 600 V CAT III,Pollution Degree 2
|
Electromagnetic Environment
|
IEC 61326-1:Portable
|
Electromagnetic Compatibility
|
Only suitable in Korea. A Class equipment(Broadcasting and communications equipment)
|