Sensor Typ D-02
O2 Sensor Type D-05J

O2 Sensor Type D05J

O2 Sensor Type D05J suitable for Rebreather JJ-CCR

The O2 - Scuba Diving Sensor Type D05J has following Specifications:

Galvanic gas sensor with an extra water repellent head space. All characteristics are based on conditions at 25°C, 50% RH and 1013 hPa.

Electrical Connector SMB Right Angel Jack with wire, 59K214-303L5 Type Rosenberger
Measurement Range 0 - 100 Vol. %
Sensor Lifetime < 2 years @ ambient air
Expected Operating Life ~ 500,000 Vol.% h
Initial Output Signal 8 to 13.5 μV @ dry ambient air
Response Time t90 < 7 sec
Drift < 1 % volume O2/ month @ air, averaged across 12 months
Linearity Error < 3 % @ 100 % O2, applied for 5 min
Zero Offset Voltage < 200 μV in 100 % N2, applied for 5 min
Operating Temperature 0 to 45 °C
Pressure Range 600 to 2500 hPa
Influence of Humidity -0.03 % rel. O2 reading per % RH
Recommended Load Resistor ≥ 10 kOhm
Temperature Compensation NTC
Interferences none to He, H2 and CO
Weight approximately 24 g
Material in Contact with Media PA, PPS, PTFE, stainless steel

Storage conditions

Temperature Range recommended: 5 to 30 °C, maximum: -20 to 50 °C
Humidity up to 100 % Rh, non- condensing
Shelf Life < 6 months recommended

You can find some more product informations here: