Universal Treadmill inverter with dispay Universal treadmill controller kit for AC motor treadmill commercial treadmill inverterwarranty:3 months


Package include:

1-2.0HP / 1-4.0HP  controller *1

Display controller *1

safety key *1

cable *1


MAX speed: 12km/h( Adjustable)


220V AC input (leave message for 110V or other), Apply for AC motor 1-3HP


This controller set can work 100% without a speed sensor, so no need to worry.


The controller of this kit with 3 pin, if your speed sensor magnetic with only 2 pin, connect 2 pin to 2 of 3pins of the controller is OK can use!


Please make sure:

a. Motor performance OK

b. Transmit function OK, especially belt, lubrication normal.

c. Only work for home treadmill use DC motor.

(How to test the motor is described in detail below)


Real photo ↓





Controller type discrimination:





4.Please make sure that there is no problem with the motor before you place your order.The motor can be tested by the method shown in the picture below. If the motor running smoothly by 5# battery, that means the motor is good. If running not smoothly or do not running, it means the motor broken.


5.Error code troubleshooting(Below info for your reference.):

E01: communication failure: console board and control board cannot communicate.probably console board issue or control board issue or data cable issue. replace a data cable,checking whether the machine can running? If no, Replace the control board.
E02: control board or motor issue. Test the motor first to check if the motor can runing normally. If motor is normal, replace the control board.
E03: 1,Turn on the treadmill , motor running a few seconds then stop and console board shows E03, probably the Speed sensor issue.
2,Turn on the treadmill,motor can't runing and console board shows E03, probably the control board issue .Test the motor first to check if the motor can runing normally. If motor is normal:    1,replace speed sensor; 2,replace control board
E04: generally over-current fault:components of control board has burned. replace burned components or replace control board.
E05:Current overload protection or Unstable speed.check the components on control board, if they connect normally? If not, re-plug the components or replace the control board.
E06:Motor overload.Test the motor first to check if the motor can running normally. If motor is normal, replace the Current limiting resistor on control board or replace whole control board.
E07:console board issue.replace console board cricuit board or replace data cable.
E08 :There may be a lift motor control fault.le)